![DTS SLICE Free Motion Headform User Manual Download Page 11](http://html1.mh-extra.com/html/dts/slice-free-motion-headform/slice-free-motion-headform_user-manual_2536097011.webp)
SLICE Free Motion
Headform User’s Manual
January 2018
11
(Rev. 0)
Level Trigger Setup
The SLICE FMH
Headform system works best when a “level trigger” is set on one or
multiple channels. This will trigger the system and record data when the sensors see g-
levels outside of a specified range.
6.
With SLICEWare running and the SLICE FMH Headform system connected (step 4
above), select the sensor you want to use for level trigger.
7.
Select the checkboxes and Enter the desired level trigger. Choose a g-value that
that is well under your expected test value but not too low that handling or a small
bump will trigger the system. Click the Apply button when finished.
How to Auto-Arm the SLICE FMH Headform System
The “Auto
-
Arm on Boot” feature allows users to automatically arm the system using
user-selected parameters at system power-up/initialization. To use the auto-arm
feature, all DAS in the test must support the auto-arm function.
8.
With SLICEWare running and the SLICE FMH Headform system connected (step 4
above), go to the
tab and perform a quick check to verify the hardware
is working properly.
Note: You will see a red box if your battery voltage is too low. The system should
to be charged for up to an hour before you start your test.