DTS SCENA LED 120 HQS User Manual Download Page 13

 

13 

 

10- RDM FUNCTIONS 
 

By using a RDM controller it is possible to set DMX address, DMX mode and other 
parameters. 
SCENA LED 120 HQS accepts the following RDM commands: 
 

RDM Device Model ID: 0x0D6F 
 

RDM PID DESCRIPTION 

RDM PID VALUE 

GET 

SET 

Category 

– Network Management 

  

  

  

DISC_UNIQUE_BRANCH 

0x0001 

  

  

DISC_MUTE 

0x0002 

  

  

DISC_UN_MUTE 

0x0003 

  

  

Category 

– Status Collection 

  

  

  

STATUS_MESSAGES 

0x0030 

  

STATUS_ID_DESCRIPTION 

0x0031 

  

Category - RDM Information 

  

  

  

SUPPORTED_PARAMETERS 

0x0050 

  

PARAMETERS_DESCRIPTION 

0x0051 

  

Category 

– Product Information 

  

  

  

DEVICE_INFO 

0x0060 

  

DEVICE_MODEL_DESCRIPTION 

0x0080 

  

MANUFACTURER_LABEL 

0x0081 

  

DEVICE_LABEL 

0x0082 

SOFTWARE_VERSION_LABEL 

0x00C0 

  

Category - DMX512 Setup 

  

  

  

DMX_PERSONALITY 

0x00E0 

DMX_PERSONALITY_DESCRIPTION 

0x00E1 

  

DMX_START_ADDRESS 

0x00F0 

Category 

– Sensors 

  

  

  

SENSOR_DEFINITION 

0x0200 

  

SENSOR_VALUE 

0x0201 

Category 

– Power/Lamp Settings 

  

  

  

DEVICE_HOURS 

0x0400 

  

LAMP_HOURS 

0x0401 

  

Category 

– Display Settings 

  

  

  

DISPLAY_INVERT 

0x0500 

Category 

– Control 

  

  

  

IDENTIFY_DEVICE 

0x1000 

 

Category 

– Dimmer Settings 

(Additional Messages)

 

  

  

  

CURVE 

0x0343 

CURVE_DESCRIPTION 

0x0344 

  

OUTPUT_RESPONSE_TIME 

0x0345 

OUTPUT_RESPONSE_TIME_DESCRIPTION 

0x0346 

  

MODULATION_FREQUENCY 

0x0347 

MODULATION_FREQUENCY_DESCRIPTION 

0x0348 

  

 
 
 
 
 

Summary of Contents for SCENA LED 120 HQS

Page 1: ...SCENA LED 120 HQS USER S MANUAL rel 1 0 GB...

Page 2: ...e products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ven...

Page 3: ...Prevention of electric shock 8 6 3 Safety 8 6 4 Waste Electrical and Electronic Equipment directive 8 7 INSTALLATION 9 8 INPUT OUTPUT CONNECTIONS 10 9 DMX SIGNAL CONNECTION 11 9 1 DMX Addresses 12 9 2...

Page 4: ...SK THIS SYMBOL INDICATES GENERAL RISK THIS SYMBOL INDICATES THE MAXIMUM OPERATING AMBIENT TEMPERATURE THIS SYMBOL MEANS DO NOT STARE AT THE OPERATING LIGHT SOURCE THIS SYMBOL INDICATES PHOTOBIOLOGICAL...

Page 5: ...a compact LED based projector suitable for all demanding applications where a perfect color rendition is paramount such as theatres and TV studios The unit features a high efficiency 120 W 4 color LED...

Page 6: ...Uploader Power supply Full range 100 240Vac 50 60 Hz Power consumption 120W Max Connections Power supply PowerCON TRUE1 In Out panel connectors DMX XLR 5 pole In Out panel connectors Internal safety d...

Page 7: ...finishing already installed on the projector Code 02M00422 46 1 x User s Manual Optional on request Barndoor black finishing Code 03 TA206 C Clamp G50 Max Load 10 Kg Code 0521A012 C Clamp G60 Max Load...

Page 8: ...ht source The luminaire should be positioned so that prolonged staring into the luminaire at a distance of 6 m is not expected The light source contained in this luminaire shall only be replaced by th...

Page 9: ...iling It is recommended the use of appropriate clamps to fix the unit to the mounting surface ATTENTION A safety cable code 0521A010 must be securely fixed to the unit s mounting bracket and to the su...

Page 10: ...owerCON TRUE1 male panel connector MAINS OUT 100 240Vac 50 60 Hz MAX 16A PowerCON TRUE1 female panel connector Max 20 units 230Vac Max 10 units 100Vac FUSE T 2A 250V DISPLAY PANEL DMX IN XLR 5 pole ma...

Page 11: ...of the second one In this way all the projectors are cascade connected If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX receptio...

Page 12: ...he next projector just add 10 Projector 3 A021 A projector 6 A051 9 2 Selecting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start t...

Page 13: ...EVICE_INFO 0x0060 X DEVICE_MODEL_DESCRIPTION 0x0080 X MANUFACTURER_LABEL 0x0081 X DEVICE_LABEL 0x0082 X X SOFTWARE_VERSION_LABEL 0x00C0 X Category DMX512 Setup DMX_PERSONALITY 0x00E0 X X DMX_PERSONALI...

Page 14: ...BER2 NO DMX 0x901C X X INT2 NO DMX 0x901D X X RED2 FINE NO DMX 0x901E X X GREEN2 FINE NO DMX 0x901F X X BLUE2 FINE NO DMX 0x9020 X X AMBER2 FINE NO DMX 0x9021 X X INT2 FINE NO DMX 0x9022 X X RED3 NO D...

Page 15: ...2 SMOOTH 2 50 ms 3 3 SMOOTH 3 75 ms 4 4 SMOOTH 4 100 ms default 5 5 SMOOTH 5 125 ms 6 6 SMOOTH 6 150 ms 7 7 SMOOTH 7 175 ms 8 8 SMOOTH 8 200 ms 9 9 SMOOTH 9 225 ms 10 10 SMOOTH 10 250 ms 11 11 SMOOTH...

Page 16: ...Hz 8 8 3500 Hz 9 9 4000 Hz 10 10 4500 Hz 11 11 5000 Hz RDM MANUFACTURER SPECIFIC PIDs MANUFACTURER SPECIFIC PID DESCRIPTION BOOST 0 Disabled 1 Enabled default FANS SETTING 0 Fan mode Standard 1 Fan m...

Page 17: ...5 Default 128 BLUE2 FINE NO DMX Range 0 255 Default 128 AMBER2 FINE NO DMX Range 0 255 Default 128 INT2 FINE NO DMX Range 0 255 Default 128 RED3 NO DMX Range 0 255 Default 128 GREEN3 NO DMX Range 0 25...

Page 18: ...code 03 LA 206 DTS Firmware Upgrade Utility v 2 02 program installed on PC Latest firmware release available for SCENA LED 120 HQS unit Updating the firmware release Please follow the procedure below...

Page 19: ...ons MENU To access the control menus in the display panel To return to the previous level in the menu structure without making a change To exit the menus ENTER To select any required menu To confirm a...

Page 20: ...ode 11 DMX channels Allows to select the value of the delay in milliseconds for Dimmer channel reaction to DMX or Program variation Off Instant response to DMX variation 4 100 ms Smooth response to DM...

Page 21: ...customizable Colour Macros RGBA values selectable by user Default 255 Rainbow colours effect Speed time value in seconds selectable by user Default 10 28 Colour Macros as on DMX channel 9 MACRO COLOR...

Page 22: ...r AUTO CHPR menu Speed time and wait time values in seconds selectable by user Default 10 In Auto mode the unit do generate DMX for slave units RGBA 100 RGBA 60 Custom RGBA RGBA Fine Dimmer and Dimmer...

Page 23: ...scene as last scene DMX channel 13 RECORDING channel Records the set scene with a variation between 0 to 255 the display flashes indicating that the scene has been recorded It is advised that you keep...

Page 24: ...oller temperature detected over 70 C Unit immediately goes in black out Thermal sensor on outputs 1 and 2 of LED Driver board damaged open or in short circuit Unit immediately goes in black out Temper...

Page 25: ...30 ms 120 149 Pulse up from 42 6 s to 120 ms 150 179 Pulse down from 42 6 s to 120 ms 180 204 Random strobe R G B W CCT MACRO Dimmer channels active 205 229 Full independent random strobe Dimmer chan...

Page 26: ...ILTER NO 122 FERN GREEN 110 255 4 0 LINEAR 47 255 1 0 QUADRATIC 81 85 COL 14 GEL FILTER NO 126 MAUVE 255 0 41 0 LINEAR 255 0 7 0 QUADRATIC 86 90 COL 15 GEL FILTER NO 132 MEDIUM BLUE 0 255 155 0 LINEAR...

Page 27: ...50 ms 29 30 SMOOTH 3 75 ms 31 32 SMOOTH 4 100 ms DEFAULT 33 34 SMOOTH 5 125 ms 35 36 SMOOTH 6 150 ms 37 38 SMOOTH 7 175 ms 39 40 SMOOTH 8 200 ms 41 42 SMOOTH 9 225 ms 43 44 SMOOTH 10 250 ms 45 46 SMOO...

Page 28: ...Dimmer Dimmer Fine values selectable via NDMX CUSTOM menu via RDM Custom PID or via PROM mode 185 194 RESERVED 195 204 RESERVED 205 214 RESERVED 215 224 RESERVED 225 234 RESERVED 235 244 FAN STANDARD...

Page 29: ...r channels active 236 255 Open 6 DIMMER 0 255 Proportional master dimmer From Off lev 0 to Full On lev 255 FINE mode 10 channels 1 RED 2 RED FINE 3 GREEN 4 GREEN FINE 5 BLUE 6 BLUE FINE 7 AMBER 8 AMBE...

Page 30: ...O DMX ACTION KEEP LAST DMX DEFAULT 20 29 NO DMX ACTION BLACK OUT 30 39 NO DMX ACTION RGB 100 40 49 NO DMX ACTION RGB 60 50 69 RESERVED 70 79 NO DMX ACTION CUSTOM flashing RED x2 confirm NO DMX ACTION...

Page 31: ...STORE CUSTOM 3 CREATE set ch11 to value 0 9 and set desired RGBA Dimmer levels STORE set ch11 to value 232 and wait 5 seconds flashing BLUE x3 confirm CREATE AND STORE CUSTOM 3 233 CREATE AND STORE C...

Page 32: ...O 9001 2015 standard D T S Illuminazione s r l Via Fagnano Selve 12 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it Product and specifica...

Reviews: