13
11.1-DMX Addresses
NICK NRG 1200 CT can be controlled with 20 DMX channels.
In order to use the unit in 20 channels, set the following addresses on the mixer:
Projector 1 A001
Projector 2 A021
If you want to select
the next projector, just add “20”
Projector 3 A041
…..
A….
projector 6
A101
11.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers
on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop
flashing and the projector is now setted to the new DMX address.
TRICKS:
if you keep pushed the UP or DOWN keys, the channels are calculated more quickly
and you get a faster selection.
12- FIRMWARE UPDATING
Warning:
This procedure require a base knowledge of computer applications and Windows
Hyperterminal program.
Please refer to an authorised D.T.S. service centre.
To update the software version of the NICK NRG 1200 you need:
D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).
USB-DMX Driver for the D.T.S. RED BOX interface.
D.T.S. Firmware upgrade utility program.
(The driver and the installation procedure are available in our web site
www.dts-lighting.it)
Updating the software version.
Please follow the procedure below to perform the update:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the
unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using D.T.S. Firmware upgrade
utility program.
!