13- AUTOFOCUS CALIBRATING PROCEDURE
It is possible to calibrate the Autofocus by following a display wizard procedure into
Calibration Menu.
Reset the unit from RESET display menu (RESET>NOW
– press ENTER to confirm)
and while the reset is running press MENU and ENTER keys at the same time to
access into Calibration Menu.
Scroll till “AUTOFOCUS calibration procedure” menu and press ENTER.
1) Select the desired distance (Min 7
– Max 15 meters) from the projection surface and
press ENTER. We suggest to place the unit 7 meters distance from the projection
surface with FOCUS FINE channel set to DMX value 127 and ZOOM channel set to
DMX value 050 (range 0-255).
2) From DMX controller adjust the Focus on the Fixed Gobo (automatically projected
@ Min Zoom) and press ENTER.
3) From DMX controller adjust the Focus on the Fixed Gobo (automatically projected
@ Max Zoom) and press ENTER.
4) From DMX controller adjust the Focus on the Rotating Gobo (automatically
projected @ Max Zoom) and press ENTER.
Autofocus calibrating procedure is now completed.
Scroll till
“ESC” menu and press ENTER.
The unit is ready for use.
AUTOFOCUS
MENU ENTER DOWN
UP
CALIBRATION PROCEDURE
MENU ENTER DOWN
UP
SELECT CALIBRATION
PROCEDURE DISTANCE
METERS
7
MENU ENTER DOWN
UP
PLEASE FOCUS FIXED GOBO
BY DMX AND PRESS ENTER
MENU ENTER DOWN
UP
FOCUS AGAIN FIXED GOBO
BY DMX AND PRESS ENTER
MENU ENTER DOWN
UP
FOCUS ROTATING GOBO
BY DMX AND PRESS ENTER
AUTOFOCUS
AUTOFOCUS
AUTOFOCUS
AUTOFOCUS