![DTS JED User Manual Download Page 12](http://html1.mh-extra.com/html/dts/jed/jed_user-manual_2536183012.webp)
12
9- MAINS CONNECTION
JED operates at 100-240Vac 50-60 Hz.
Prior to connecting the unit to your mains supply, ensure that the model in your
possession correctly matches the mains supply available.
For connection purposes, ensure that your plug is capable of supporting 1 amps
at 230Vac or 2 amps at 100Vac each unit connected.
Strict adherence to regulatory norms is strongly recommended.
MAINS INPUT 100-240Vac 50-60 Hz
PowerCon TRUE1 male panel connector
MAINS OUTPUT 100-240Vac 50-60 Hz (MAX 16A)
Max 14 JED units @ 230Vac
Max 7 JED units @ 100Vac
PowerCON TRUE1 female panel connector
FUSE T 2A 250V
9.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each JED.
A good earth connection is essential for the correct operation of the projector.
!
Summary of Contents for JED
Page 1: ......
Page 40: ...40 19 ROTATING GOBO WHEEL ...
Page 41: ...41 20 FIXED GOBO WHEEL ...
Page 42: ...42 21 COLOUR WHEEL ...
Page 43: ...43 NOTES ...