User Manual
Ver. 1.02
15 di 20
DOCTUS.D
5.5.2.1 Termination Resistor
In DMX RDM connections, the use of a termination resistor is necessary to minimize reflections and provide
good communication.
The value of the termination resistor is 120 Ohm and should be placed near the two ends of the communication
network. Some control units provide a built-in termination resistor.
5.5.3 Connessioni
DOCTUS.D fixtures are provided with an end-stripped 4-pole cable.
The following table allows to match each cable, through its color, with the associated signal
CONNECTIONS
Funtion
Signal
Wire color
Power supply
Positive: +V dc
Brown
Negative: -V dc
Black
RDM DMX Communication bus
Data +
Light Blue
Data -
White
5.5.4 Connection logic diagram
In accordance with the previous paragraphs, the connection of two or more DOCTUS.Ds must comply with the
following connection logic diagram:
5.5.5 Maximum Distance
If it is necessary to install the product away from the power source and the control unit, consider that:
•
Cable splices and product connections must be made as specified above.
•
The maximum distance that can be reached must take into account both the characteristics of the
communication network and those of the power supply.
•
Cable junctions must be made as recommended both for correct electrical operation and to maintain
the IP protection rating.
Summary of Contents for DOCTUS.D 1
Page 1: ......
Page 2: ......
Page 3: ...User Manual Ver 1 02 1 di 20 DOCTUS D Release 1 02 Code For more information Language EN...
Page 22: ...User Manual Ver 1 02 20 di 20 DOCTUS D NOTES...
Page 23: ......