4.2 Before the Installation
4.2.1 Check-up List for the Installation
•
Prepare all cables and necessary accessories.
•
Test the DOCTUS before installing. Pay attention not to damage cables/connectors during check-up.
•
Ensure that all check-ups described within this document are thoroughly followed.
•
Place the DOCTUS on the desired position. If the installation can’t be finished before nightfall, store
the devices and their cables inside a closed and dry place.
Before installation, please make sure that all devices and cables are kept in a dry place. This will avoid
humidity to be retained inside them, avoiding failure of the products.
4.2.2 Tips for the Installation
•
DO NOT try to install the device in rainy or adverse meteorological conditions.
•
DO NOT leave and expose the DOCTUS or their power supply unit disconnected in wet environment
or rain/snow conditions.
•
IP rating failures caused by damaged/strained cables (during or after the installation) will cancel the
warranty issued by D.T.S. Illuminazione S.r.l.
•
ALWAYS keep the cables protected from pointy objects and ensure that no cable is damaged.
•
Failing to keep the DOCTUS into the -10 to 45 °C operating temperature range (14 to 113 °F) and the
-25 to 60 °C storage temperature range (-13 to 140 °F), will cancel the warranty issued by D.T.S.
Illuminazione S.r.l.
•
Do not obstruct or submerge the Gore valve.
•
Fasten the projector with screws, clamps, or other supports capable of sustaining their weight. If
necessary, use a safety cable.
•
It is recommended the use of an adequate residual current device/circuit breaker on the power supply
mains.
•
This fixture is susceptible to overvoltage. The installation of a protection device on the electrical
system can diminish the intensity of these phenomena, protecting the fixtures from possible damage.
4.2.3 Preparation Procedure for Cables and Connectors
•
Test all DOCTUS units before the installation.
•
Report any operational defects to D.T.S. Illuminazione S.r.l or their official distributor or dealer.
•
Do not install any DOCTUS that presents any operational defect.
•
Plan any potential cable folding (please refer to the following paragraph “Cable Folding”).
•
Fasten both ends of the cables with connections fit for the environment in which they are made.
•
Connect the DOCTUS to their power supply units with appropriate connection cables.
•
Cut the cable to the necessary length.
•
Should the length of the cables be insufficient, provide an extension by using a cable with the same
features. The junction between the two must be ranked at minimum IP65, or be made and left in a
closed and dry location.
•
Should the cables be damaged, they must be adequately repaired by restoring their IP protection