DTS DELTA 10 F User Manual Download Page 11

10.1 DMX Addresses:

DELTA 10 F can be used in 3 different DMX modes: 10 DMX control channels, 6 DMX control channels or
CUSTOM mode channels.
Here below is described the DMX channels addressing for the controller when Delta 10 f is set to
 10 DMX control channels :

Projector 1

A001

Projector 2

A011 If you want to select the next projector, just add “10”

Projector 3

A021

…..

A….

projector 6

A051

10.2 Selelcting the DMX address:

1) Press the UP-DOWN key until you reach the required DMX address. The numbers on the display will 
start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the 
projector is now controlled by the new DMX address.

TIPS: if you keep pushed  the UP or DOWN keys, the channels are calculated more quickly and you get 
a faster selection.

Please refer to an authorised D.T.S. service centre.

  

D.T.S. Firmware upgrade utility program.

D.T.S. Firmware upgrade utility

11 FIRMWARE UPDATING

Warning: 

This procedure require a base knolewge of computer applications and Windows
Hyperterminal program. 

To update the software version  of the DELTA 10 F you need:
D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).
USB-DMX Driver for the D.T.S. RED BOX interface .

(The driver and the installation procedure are available in our web site www.dts-lighting.it)

Updating the software version.

Please follow the procedure below to perform the update:

1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using 

 program. 

It will be possible to download the software from the reserved area of D.T.S. web site:
 www.dts-lighting.it.

11

    DELTA 10 F

!

Summary of Contents for DELTA 10 F

Page 1: ...B Made in Italy DELTA 10 F User s Manual rel 1 3 D T S Illuminazione srl ITALY http www dts lighting it IP65 03 LDF004 T12 03 LDF004 T25 03 LDF004 T45 03 LDF004 T12 WS 03 LDF004 T25 WS 03 LDF004 T45 W...

Page 2: ...of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas...

Page 3: ...d matter 7 VOLTAGE AND FREQUENCY 8 8 INSTALLATION 8 8 1 Safety cable 8 2 Protection against liquid 8 3 Movement 8 4 Risk of fire 8 5 Forced ventilation 8 6 Ambient temperature 9 MAINS CONNECTION 9 9 1...

Page 4: ...lamp The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS T...

Page 5: ...on different colours special effects etc which can be played back in a predetermined sequence over an entire week The DELTA 10 F RGBW can operate in vertical horizontal or inverted positions and can b...

Page 6: ...dium flood 25 Code 03 LK 064 Lenses set Wide flood 45 Code 03 LK 065 Lenses set Elliptical 15 x 45 Code 03 LK 063 Diffusion Frost Glass Code 0506V022 F Wireless DMX receiver card Code 03 LA 012 Extern...

Page 7: ...roper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 6 3 Protection against direct light radiat...

Page 8: ...points on the bottom used to attach accessories clamps hooks etc We recommend the use of a safety cable or chain connected to the Delta 10 F and to the suspension truss in order to avoid the fixture a...

Page 9: ...C Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available 9 MAINS CONNECTION Delta 10 F can operate at 90 260V 50 or 60...

Page 10: ...DMX signal not present DMX address not valid DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a mal...

Page 11: ...aster selection Please refer to an authorised D T S service centre D T S Firmware upgrade utility program D T S Firmware upgrade utility 11 FIRMWARE UPDATING Warning This procedure require a base knol...

Page 12: ...REVERSE DISPLAY Reverses display s reading depending on the mounting position On the ground or suspended Up Down Floor position Suspension position Up Down ENTER Up Down ENTER DISPLAY STAND BY To tur...

Page 13: ...ent output COMPRESSION This menu allow to select between Linear current output or Quadratic current output for LEDs Default Linear Quadratic Linear light output ENTER Up Down ENTER ENTER ENTER Default...

Page 14: ...mmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCE...

Page 15: ...jump back to normal mode and continue transmitting data The Delta 10 F now try to synchronize to the transmitter When synchronized to the transmitter 2 different modes are possible 1 Antenna transmit...

Page 16: ...select one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas Up Down MENU Up Down ENTER Up Down EN...

Page 17: ...be set at A001 For RaIn rainbow game it is possible to select the speed for the colour changhing SPEE DIMMER function in AUTOMATIC MODE is active for all the programs SHUTTER function in AUTOMATIC MOD...

Page 18: ...ction From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to recor...

Page 19: ...ical parts and the gaskets replacing them if necessary Electrical components Check all electrical components for correct earthing and proper attachment of all connectors refastening if necessary Fuse...

Page 20: ...Medium flood 25 Wide flood 45 Elliptical 15 x 45 proceed as follow Remove these 6 screws on both sides of the rear head assembly Remove the top head cover Loose these 4 screws and remove only the fro...

Page 21: ...e at variable speed from slow to fast 3400ms 20ms 120 149 192 218 Pulse open at variable speed from slow to fast 43s 100ms 240 150 179 180 204 205 229 230 255 Open Black out Pulse close at variable sp...

Page 22: ...d 43 color temp Correction Macros 2000 K 7200 K DMX CHANNEL 7 Parameter WHITE Pre programmed White at diff color temperature Move DMX range Mid point Mode Option Function Value DMX value range degrees...

Page 23: ...Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro Macro Macro Macro 13 Macro 14 Macro 15 240 255 Macro 16 DMX CHANNEL 8 Parameter CTC Color temperature correction Move DMX rang...

Page 24: ...ec 247 255 Rainbow Speed 2 5 Sec Rainbow Speed 3 10 Sec Rainbow Speed 4 20 Sec Rainbow Speed 5 30 Sec Rainbow Speed 6 60 Sec Rainbow Speed 7 120 Sec Rainbow Speed 8 180 Sec Random Speed 3 2 Sec Random...

Page 25: ...218 Pulse open at variable speed from slow to fast 43s 100ms 240 150 179 180 204 205 229 230 255 Open Black out Pulse close at variable speed from slow to fast 43s 100ms Random Strobe Master and RGBA...

Page 26: ...Option Function 0 255 Proportional colour DMX CHANNEL 5 Parameter BLUE DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 255 Proportional colour DMX CHANNEL 6 Parameter AMB...

Page 27: ...27 NOTE DELTA 10 F...

Page 28: ...ic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumina...

Reviews: