DTS BRICK User Manual Download Page 32

 

32 

 

The  information  contained  in  this  publication  has  been  carefully  prepared  and 
checked. However, no responsibility will be taken for any errors. All rights are reserved 
and  this  document  cannot  be  copied,  photocopied  or  reproduced,  in  part  or 
completely, without prior written consent from DTS.  
DTS reserves the right to make any aesthetic, functional or design modifications to any 
of  its  products  without  prior  notice.  DTS  assumes  no  responsibility  for  the  use  or 
application of the products or circuits described herein. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 

D.T.S. Illuminazione s.r.l. 

– Via Fagnano Selve 10-12-14 47843 

Misano Adriatico (RN) Italia 

Tel.: +39 0541 611131. Fax + 39 0541 611111  

 

[email protected]

   

www.dts-lighting.it

 

  

0517I291 

MADE IN ITALY

ISO 9001:2008

DTS quality system

is certified to the

ISO 9001:2008 standard

DTS products are designed

and manufactured at the

DTS plants in Italy

*0517I291*

Summary of Contents for BRICK

Page 1: ......

Page 2: ...e products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ven...

Page 3: ...ective 9 7 INSTALLATION 9 7 1 Protection against liquids 11 7 2 Movement 11 7 3 Risk of fire 11 7 4 Forced ventilation 12 7 5 Ambient temperature 12 8 INPUT OUTPUT CONNECTIONS 12 8 1 Internal fuse 13...

Page 4: ...OPERATING AMBIENT TEMPERATURE THIS SYMBOL MEANS SUITABLE FOR MOUNTING ON NORMALLY FLAMMABLE SURFACES THIS SYMBOL INDICATES THE MINIMUM DISTANCE FROM THE ILLUMINATED OBJECTS THIS SYMBOL MEANS DO NOT ST...

Page 5: ...geable no tools required BRICK comes with an IP65 power cable plus 2 DMX cables with M F XLR connectors all IP65 that make it perfect for temporary lighting applications but also for safe long lasting...

Page 6: ...full range PSU 100 240Vac 50 60 Hz Consumption 400VA Max Connections Power supply 3 x 1 sq mm cable 1 5 m length DMX In Out 0 7 m cable with XLR 5 pins IP65 connector Operating ambient temperature 10...

Page 7: ...Bracket for ground installation code 03 LA 213 Barndoor black finishing code 03 LA 210 Permanent installation kit IP68 Power connector 2 x DMX In Out connectors code 03 LA 214 Aliscaf clamp for tube d...

Page 8: ...ir ventilation 6 3 Safety Risk Group 2 product according to EN 62471 CAUTION Do not look directly into the light output May be harmful to the eyes and skin Do not stare at the operating light source T...

Page 9: ...c Equipment and its implementation into national right luminaires that are no longer usable must be collected separately and disposed of in an environmentally correct manner 7 INSTALLATION The unit is...

Page 10: ...nit as should any clamps used to hung it For outdoor application where BRICK needs to be installed vertically keep the unit display towards the floor A permanent installation kit IP68 code 03 LA 214 i...

Page 11: ...ector has a maximum movement of 110 for Tilt 7 3 Risk of fire Each fixture produces heat and must be installed in a well ventilated place It is permissible to place the unit on normally flammable mate...

Page 12: ...ances be blocked or obstructed whilst the projector is in operation Doing so could cause the fixture to seriously overheat thereby compromising its proper operation 7 5 Ambient temperature The project...

Page 13: ...s can damage the IP65 protection To access the internal fuse loose the 6 marked screws which fix the lateral cover on display panel opposite side and remove the cover Use only replacement fuses rated...

Page 14: ...of the second one In this way all the projectors are cascade connected If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX receptio...

Page 15: ...numbers on the display will stop flashing and the projector is now controlled by the new DMX address 10 RDM FUNCTIONS By using a RDM controller it is possible to set DMX address DMX mode and other par...

Page 16: ...he DTS RED BOX interface DTS Firmware Upgrade Utility v 2 02 program installed on PC Latest firmware release available for BRICK unit Updating the software version Please follow the procedure below to...

Page 17: ...es not respond to the DMX 512 used to control it Carefully follow the instructions below before carrying out any variations or selections MENU To access the control menus in the display panel To retur...

Page 18: ...ust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings Default 610 Hz Allows to increase the LED s current from 1050mA to 1500mA per channel Default ON A...

Page 19: ...fans speed for a very low noise operation Default STD No DMX action Keep last valid DMX signal Default Black out Chase with 16 steps previously created in REC mode as per AUTO CHPR menu Speed time and...

Page 20: ...display flashes indicating that the scene has been recorded It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not...

Page 21: ...Please refer to an authorised DTS service centre for any operation involving of the unit if needed Electrical components Check for unit proper earthing Please refer to an authorised DTS service centre...

Page 22: ...ly install the holographic filter 1 Put in place the bottom edge of the filter 2 Bend the filter 3 Insert the top edge of the filter For permanent outdoor installation the holographic filter can also...

Page 23: ...placement must be made by DTS personnel or experienced person Wrong operations can damage the IP65 protection 1 Remove the front screen with the protection glass by loosing the 8 marked screws 2 Remov...

Page 24: ...r BRICK code 03 LA 210 is available on demand Fix the barndoor on the BRICK by using the 4 marked knobs provided in the box Once installed fix the safety cable on the lateral cover by using the screw...

Page 25: ...Black out 30 119 Strobe da 3 27 s a 30 ms 120 149 Pulse up da 42 6 s a 120 ms 150 179 Pulse down da 42 6 s a 120 ms 180 204 Random strobe Warm White Cold White Dimmer Dimmer Fine active 205 229 Indepe...

Page 26: ...O 122 FERN GREEN R115 G255 B0 W19 115 124 COL 11 LEE FILTER NO 126 MAUVE R255 G0 B55 W0 125 134 COL 12 LEE FILTER NO 137 LAVENDER R232 G197 B49 W37 135 144 COL 13 LEE FILTER NO 139 PRIMARY GREEN R30 G...

Page 27: ...800 Hz 106 OUTPUT FREQUENCY 1000 Hz 107 OUTPUT FREQUENCY 1500 Hz 108 OUTPUT FREQUENCY 2000 Hz 109 OUTPUT FREQUENCY 2500 Hz 110 OUTPUT FREQUENCY 3000 Hz 111 OUTPUT FREQUENCY 3500 Hz 112 OUTPUT FREQUENC...

Page 28: ...GREEN 3 BLUE 4 WHITE Ch Name DMX levels 1 RED 0 255 Proportional color from min to max 2 GREEN 0 255 Proportional color from min to max 3 BLUE 0 255 Proportional color from min to max 4 WHITE 0 255 Pr...

Page 29: ...29 NOTES...

Page 30: ...30 NOTES...

Page 31: ...31 NOTES...

Page 32: ...hetic functional or design modifications to any of its products without prior notice DTS assumes no responsibility for the use or application of the products or circuits described herein D T S Illumin...

Reviews: