17
MAIN MENU
LEVEL 1
LEVEL 2
LEVEL 3
FUNCTION
To restore default settings
LED temperature monitoring
Micro controller temperature
monitoring
Output 1 of LED Driver board
temperature monitoring
Output 4 of LED Driver board
temperature monitoring
Shows the total unit life time and
LED life time
Software version
13- MANUAL MODE
Manual mode can be activated by pressing at the same time
‘UP’ and ‘DOWN’ keys
on unit display for 3 seconds (A001).
In Manual mode it is possible to select the DIMMER level (range 0-255) as on DMX
channel 2 and SHUTTER level (range 0-255) as on DMX channel 1.
When Manual mode is active, unit switch OFF/ON cycle will maintain Manual Mode
selection.
In Manual mode the DMX signal is ignored.
14- ERROR MESSAGES
ERROR SHOWED ON DISPLAY
APPEARS WHEN
LED thermal sensor damaged (open or in
short circuit).
Unit immediately goes in black-out.
LED temperature detected over 100°C.
Unit immediately goes in black-out.
Micro controller thermal sensor damaged
(open or in short circuit).
Unit immediately goes in black-out.
Micro controller temperature detected over
100°C.
Unit immediately goes in black-out.
Thermal sensor on output 1 of LED Driver
board damaged (open or in short circuit).
Unit immediately goes in black-out.
Temperature detected over 100°C on
output 1 of LED Driver board.
Unit immediately goes in black-out.
Thermal sensor on output 4 of LED Driver
board damaged (open or in short circuit).
Unit immediately goes in black-out.
Temperature detected over 100°C on
output 4 of LED Driver board.
Unit immediately goes in black-out.