background image

4

V. Examplary electric scheme

230v SUPPLIED
DEVICE

L

N

230V AC

NO1

NC1 NO2

NC2

C1

C2

~230V

Control button

Control button

IN1

IN2

IN2

IN1

ELECTROLOCK

OR OTHER LOW VOLTAGE

DEVICE

12V AC

Channel 2 manual

Channel 1 manual

UVR-2 RECEIVER

VII. Declaration

Fig.3 UVR-2 receiver and electrical devices conection exemplary scheme

The intention of the WEEE Directive
(Directive 2002/96/EC on waste electrical
and electronic equipment) is to reduce the
amount of hazardous substances in waste.
The underlying purpose is to promote the
avoidance, recovery and risk-free disposal
of waste.

VII. Warranty

DTM System checks all the devices before shipping. The
warranty time is 24 months from the selling date. This time
is counted according to the warranty label. The
manufacturer will fix all the problems which come because
of his fault. Non functioning device should be delivered
back to the distributor with short problem description. The
cost of mount/dismount is covered by user. The warranty
do not cover: batteries in the remotes, faults caused by
improper usage, user self repairs and adaptations,
lightning strikes, over voltages or short circuits in the
mains supply. Appropriate legal acts regulates details of
the warranty.

I. Used terms

II. General information

III. Technical data

IV. Receiver installation

4

4

4

4

Monostable output mode – turn on for programmed time after pushing the button

Bistable output mode – switch to opposite (turn on or turn off) after pushing button

Momentary output mode – turn on as long as the button is being pushed

Manual control – operating controled by momentary buttons connected to UVR-2 board.

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

receiver supply 230 V AC

superherterodyne receiver, work frequency: 433.92 MHz,

dynamically variable code Keeloq gives high class safety

two separated relay outputs, NO or NC, max load for each output 600W

max peak current 16A/230V AC

two manual control inputs

three working mode: bistable, momentary, monostable (1s resolution for times up to 1 minute and 1min resolution for

times from 1min to 127min)

discretion with ascribing remote buttons to receivers outputs

hardware interface with 6 diodes

receiver's memory containing 35 remote controls of ZSP series

remote radio range up to 150m

single remote removing possibility

working temperatures from -20 C to +55 C

two enclosure versions: surface mounted, inside mounted, IP55

dimensions: surface mounted enclosure: 89 x 89 x 52 mm or install box of 80 mm diameter, 40 mm depth

Remote control receiver

was made for universal use – remote or manual control of electrical devices of heavy

230V loads, up to 600W. UVR-2 is compatible with DTM remotes. Exemplary application: control of gate automatic,
pomps, lightning, alarm system and more.

Receiver consists of main board and case. Main board contains: power supply, microprocessor user interface

with LED diodes, buttons and jumper, executive circuit on two relays, terminal blocks for: power supply, controlled

CAUTION!!

This installation should be made by a qualified service person and should conform to all local codes.

Device is designed to operate with high voltages.

Turn all power off while installing. System should be installed with safety, to minimalize potential risk of using.

Fitter is responsible for any presumptive damages.

1. Device description and installation

UVR-2

UVR-2 Receiver Operating manual

1

1

Made in

Poland

Reviews: