4
V. Examplary electric scheme
230v SUPPLIED
DEVICE
L
N
230V AC
NO1
NC1 NO2
NC2
C1
C2
~230V
Control button
Control button
IN1
IN2
IN2
IN1
ELECTROLOCK
OR OTHER LOW VOLTAGE
DEVICE
12V AC
Channel 2 manual
Channel 1 manual
UVR-2 RECEIVER
VII. Declaration
Fig.3 UVR-2 receiver and electrical devices conection exemplary scheme
The intention of the WEEE Directive
(Directive 2002/96/EC on waste electrical
and electronic equipment) is to reduce the
amount of hazardous substances in waste.
The underlying purpose is to promote the
avoidance, recovery and risk-free disposal
of waste.
VII. Warranty
DTM System checks all the devices before shipping. The
warranty time is 24 months from the selling date. This time
is counted according to the warranty label. The
manufacturer will fix all the problems which come because
of his fault. Non functioning device should be delivered
back to the distributor with short problem description. The
cost of mount/dismount is covered by user. The warranty
do not cover: batteries in the remotes, faults caused by
improper usage, user self repairs and adaptations,
lightning strikes, over voltages or short circuits in the
mains supply. Appropriate legal acts regulates details of
the warranty.
I. Used terms
II. General information
III. Technical data
IV. Receiver installation
4
4
4
4
Monostable output mode – turn on for programmed time after pushing the button
Bistable output mode – switch to opposite (turn on or turn off) after pushing button
Momentary output mode – turn on as long as the button is being pushed
Manual control – operating controled by momentary buttons connected to UVR-2 board.
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
receiver supply 230 V AC
superherterodyne receiver, work frequency: 433.92 MHz,
dynamically variable code Keeloq gives high class safety
two separated relay outputs, NO or NC, max load for each output 600W
max peak current 16A/230V AC
two manual control inputs
three working mode: bistable, momentary, monostable (1s resolution for times up to 1 minute and 1min resolution for
times from 1min to 127min)
discretion with ascribing remote buttons to receivers outputs
hardware interface with 6 diodes
receiver's memory containing 35 remote controls of ZSP series
remote radio range up to 150m
single remote removing possibility
working temperatures from -20 C to +55 C
two enclosure versions: surface mounted, inside mounted, IP55
dimensions: surface mounted enclosure: 89 x 89 x 52 mm or install box of 80 mm diameter, 40 mm depth
Remote control receiver
was made for universal use – remote or manual control of electrical devices of heavy
230V loads, up to 600W. UVR-2 is compatible with DTM remotes. Exemplary application: control of gate automatic,
pomps, lightning, alarm system and more.
Receiver consists of main board and case. Main board contains: power supply, microprocessor user interface
with LED diodes, buttons and jumper, executive circuit on two relays, terminal blocks for: power supply, controlled
CAUTION!!
This installation should be made by a qualified service person and should conform to all local codes.
Device is designed to operate with high voltages.
Turn all power off while installing. System should be installed with safety, to minimalize potential risk of using.
Fitter is responsible for any presumptive damages.
1. Device description and installation
UVR-2
UVR-2 Receiver Operating manual
1
1
Made in
Poland