    e.  Always avoid hot muffl ers, exhaust manifolds,
 

and engine parts.  They can cause severe 

 burns 

instantly.

     f.  The use of the engine-generator set must com-
 

ply with all national, state, and local codes.

TESTING POLICY 

Before any generator is shipped from the factory, it 
is fully checked for performance.  The generator is 
loaded to its full capacity, and the voltage, current 
and frequency are carefully checked.

Rated output of generator is based on engineering 
tests of typical units, and is subject to, and limited 
by, the temperature, altitude, fuel, and other condi-
tions specifi ed by the manufacturer of the applicable 
engines.

INTENDED USES 

These engine generator sets have been designed 
primarly for portable use.  A 120 volt GFCI AC recep-
tacle is provided in the end cover to connect your 
loads (lights, portable tools, and small appliances).

This portable unit requires large quantities of fresh 
air for cooling the engine and generator.  For safety, 
long life and adequate performance, these units 
should never be run in small compartments without 
positive fresh air fl ow.

RESTRICTED USES

DO NOT 

install and operate this generator in a small 

compartment., i.e. generator compartments of ve-
hicles, motor homes or travel trailers.  These com-
partments will not allow enough free fl ow of fresh 
air to reach the engine generator set for cooling and 
will cause the unit to overheat damaging both the 
engine and generator.  Small compartments will also 
develop hot spots where there is very little air fl ow 
and may cause a fi re.

PLEASE NOTE

  There are 3rd party companies 

making enclosures for generators that have been 
properly engineered.  The use of these 3rd party 
enclosures is acceptable as long as they have been 
certifi ed and meet current code.

DO NOT 

attempt to operate at 50 cycles.  These 

units are designed and governed to operate at 60 
cycles only.

UNIT CAPABILITIES

GENERATOR CONNECTIONS

This generator is designed for 120 volt alternating 
current (AC) use only.  A GFCI protected duplex out-
let is provided for connection to various loads.

Check the appliance or tool nameplate for the cur-
rent and voltage to insure compatability.  Although a 
circuit breaker is provided, damage due to overload-
ing constitutes abuse and will not be warranted.  Re-
fer to the generator nameplate for unit’s capabilities.

STARTING ELECTRIC MOTORS

Electric motors require much more current (amps) to 
start them than to run them.  Some motors, par-
ticularly low cost split-phase motors, are very hard 
to start and require 5 to 7 times as much current 
to start them as to run them.  Capacitor motors are 
easier to start and usually require 2 to 4 times as 
much current to start them as to run them.  Repul-
sion Induction motors are the easiest to start and 
require 1 1/2 to 2 1/2 times as much to start them as 
to run them.

Most fractional horsepower motors take about the 
same amount of current to run them whether they 
are Replulsion Induction (RI), Capacitor (Cap), or 
Split-Phase (SP) type.  The chart below shows the 
approximate current required to start and run various 
types and sizes of 120 volt 60 cycle electric motors 
under average load conditions.

HP

AMPS 
RUNNING

STARTING AMPS

SP

CAP

RI

1/6

3.2

16 to 22

6 to 13

5 to 8

1/4

4.5

22 to 32

9 to 18

7 to 12

1/3

5.2

26 to 35

10 to 21

8 to 17

1/2

7.2

not made

14 to 29

11 tp 18

1

13.0

not made

26 to 52

20 to 33

The fi gures given above are an average load such 
as a blower or fan.  If the electric motor is connected 
to a hard starting load such as an air compressor, it 
will require more starting current.  If it is connected 
to a light load, or no load such as a power saw, it will 
require less starting current.  The exact requirement 
will also vary with the brand or design of the motor.

Summary of Contents for Winco W3000H

Page 1: ...1 1203 00 60706 220 INSTALLATION AND OPERATORS MANUAL INDUSTRIAL PORTABLE W3000H...

Page 2: ...UNIT Unpacking the Unit 5 Unit Preparation 5 Initial Start Up 6 Basic Operation 6 ENGINE CARE 7 GENERATOR CARE 8 TROUBLESHOOTING 9 WARRANTY INFORMATION 10 MAINTENANCE LOG 11 PROPER USE AND INSTALLATIO...

Page 3: ...e earth 2 FIRE HAZARD Gasoline and other fuels pres ent a hazard of possible explosion and or fire a Do not refuel when the engine is running or hot b Keep fuel containers out of reach of children c D...

Page 4: ...attempt to operate at 50 cycles These units are designed and governed to operate at 60 cycles only UNIT CAPABILITIES GENERATOR CONNECTIONS This generator is designed for 120 volt alternating current...

Page 5: ...this unit meets your job requirements UNIT PREPARATION Before your generator set was shipped from our factory it was fully checked for performance The generator was load tested to its full capacity a...

Page 6: ...ditive such as STA BIL or an equivalent will minimize the formation of gum depos its during storage Such an addative may be added to gasoline in the engines fuel tank or to gasoline in a storage conta...

Page 7: ...appliances will have the volt age and amperage requirements on their individual nameplates When in doubt consult the manufac turer or a local electrician The nameplate amperage rating for electric mot...

Page 8: ...cessary to ensure a long trouble free life 1 Exercising The Generator The generator should be operated every three to four weeks It should be operated for a period of time sufficient to warm the unit...

Page 9: ...overloaded Defective stator Defective rotor field Circuit Breaker Defective load Trips Defective receptacle Voltage too high Engine speed is too high Generator Overloaded overheating Insufficient vent...

Page 10: ...r or to WINCO Inc at LeCenter Minnesota THERE IS NO OTHER EXPRESS WARRANTY To the extent permitted by law any and all warranties including those of merchantability and fitness for a particular purpose...

Page 11: ...11 1203 00 60706 220 MAINTENANCE LOG DATE HOURS ITEM WORK PERFORMED...

Page 12: ...1203 00 12 60706 220 225 S CORDOVA AVE LECENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831...

Reviews: