background image

8

NOTE: When power is applied to the 
the user has a time slot of 5 minutes to start using the
IR keyfob. The timer can be reset by either pushing the
program button as shown in fig.10 or by removing
and then reapplying power to the 

RANGE MTRS

PULSE COUNT

LED

'S' OUTPUT LUX LEVEL

CONTACTS

TIMER SECONDS

PROGRAMMING CHART

CCTV 1
CCTV 2

25

1

OFF

2

2

30

2

ON

5

5

40

10

10

40

40

50

50

24HR

60

N/O
N/O

N/C
N/O

N/C
N/C

PRESS 7 TIMES TO FLASH OUT YOUR SELECTED SETTINGS.

PRESS 8 TIMES TO RESET THE GJD FACTORY SETTINGS.

OPTIONS

AUX

45

20

20

50

30

30

1

2

3

4

5

6

1

2

3

4

5

6

7

8

SETTING

7

8

To change any of the 

 settings: -

1) Press the programme button as shown in fig. 10  (or key fob button shown in fig.

11, 12) for the number of the Option to be changed i.e.once for range, twice for
pulse count, three times for LED, four times for Lux, five times for contacts & six
times for timer.

2) Wait four seconds until the blue LED indicator goes off.

3)  The indicator will then flash out the existing setting.

4)  To change the setting for that option, press the button the number of times

required for the new setting.

5)  The indicator blinks twice and the changes are stored.

ON/OFF

Installation & Set Up Guide

Stage 4 – 

Programming (Cont.)

fig. 12

Summary of Contents for GJD 350

Page 1: ...ving a fixed 60 second trigger on activation Additionally independent front and rear tamper circuits are combined to provide a volt free tamper alarm contact The flexibility of the various outputs and timers allows the to be used in multiple situations without the need for any further customised equipment The integral dual axis tilt sensor allows 180 of pan and 90 tilt This increases the speed of ...

Page 2: ...t led is factory set to OFF Pressing the programme button once will enable the walk test led for 5 minutes THE FRONT COVER MUST BE FITTED WHEN WALK TESTING FACTORY SETTINGS ARE 1 RANGE 40 METRES 2 PULSE COUNT 1 3 LED OFF 4 CCTV1 N C CCTV2 N O 5 CONTACT TIMER 5 SECONDS The A and S connections are for use with GJD lighting controllers 2 Installation Set Up Guide ...

Page 3: ...oisture can affect or damage the unit 1 Using the template provided drill the wall to accept the two fixing screws the cable entry and the tamper cup if used See fig 1 and 2 Note We recommend using the tamper cup on uneven wall surfaces 2 Remove the cover assembly by loosening the locking screw using the allen key provided The cover hinges from the top and lifts out of the location slot See fig 3 ...

Page 4: ...d One is 1mm longer and the other is 2mm longer than the tamper foot originally fitted The tamper foot is a push fit and can be removed by carefully pulling it from the pin See fig 2 4 Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern Refer section titled Beam Alignment 5 When the detector has been aligned to su...

Page 5: ...d with two Fresnel lenses to provide a beam pattern best suited to the cameras field of view The 50 metre X 10 metre lens is fitted to the unit when manufactured If required this can be changed to the 50 metre X 5 metre lens which is supplied with the unit Movement across the beams produces the best response and range whilst movement towards the detector will be less responsive The unit detects th...

Page 6: ......

Page 7: ... can easily be made To reset the factory settings simply remove power form the detector press and hold the programme button fig 10 whilst temporarily applying power to the detector either before installation with a PP3 battery or by applying 12 Volts to the unit on site fig 11 fig 9 Installation Set Up Guide Stage3 Beam Alignment Cont fig 10 Blue LED Programme Button Stage 4 Programming ...

Page 8: ...ETTINGS OPTIONS AUX 45 20 20 50 30 30 1 2 3 4 5 6 1 2 3 4 5 6 7 8 SETTING 7 8 To change any of the settings 1 Press the programme button as shown in fig 10 or key fob button shown in fig 11 12 for the number of the Option to be changed i e once for range twice for pulse count three times for LED four times for Lux five times for contacts six times for timer 2 Wait four seconds until the blue LED i...

Page 9: ...ble on page 8 to adjust the range as necessary and pan and tilt the lens module over the field of view to obtain the correct coverage area When the program button is pressed momentarily the blue indicator lights and pulse count 1 is automatically selected The unit can then be aligned The blue indicator will light on the every time a detection takes place This test mode will automatically cancel fi...

Page 10: ...t level is below the programmed setting The S output is an open collector type rated at a maximum of 25 mA CCTV1 CCTV2 OUTPUTS These are magnetically immune volt free relay contacts used to trigger alarm inputs on connected equipment They can be set to be both normally open one normally closed and one normally open or both normally closed TIMER The timer setting adjusts the time that the relays ch...

Page 11: ...11 Installation Set Up Guide INSTALLATION NOTES ...

Page 12: ...0 7 1 0 3 ...