DSW308
Smoke Alarm User’s Manual
DSW308
is a photoelectric smoke alarm, it accords with
ISO/DIS 12239 standard. it has much effect to detect smoke.
IMPORTANCE! PLEASE READ THE MANUAL CAREFULLY
AND SAVE IT
. The manual includes important information
related to its operation, to ensure your safety, you should install
one alarm in every room at least, don
t open the alarm easily
to avoid bad effect.
Power source:
DC 9V
Static current:
<6.5uA
Alarm current:
10mA
Alarm volume:
>85db(3m)
Low voltage alarm:
6.5V+0.5V
o
o
Working temperature:
-5 C~+40 C
Working humidity:
<93%RH
In the bedroom and corridor you should install one in every
bedroom at least.
On the top of the stairway, because where is the routeway for
escape.
You had better install alarm in every compartment on every
floor, including attic and basement.
Install one beside the electronic appliance. install it in the
middle of the ceiling, because smoke always spread upwardly.
If you can’t install it in the middle, it should also be installed
beyond 10cm away from the wall(see diagram 1)
If you install it on the wall, it should be 10~30.5cm away from
the ceiling at least.(see diagram 2).
When your room’s length is beyond 9m, you should install
more than one alarm.
In the room with oblique roof(diagram 2) the alarm should be
below 0.9m away from the top.
In movable house, the alarm must be 10~30.5cm away from
the ceiling, because the kind of house has no isolation layer.
The place not fit to install
SPECIFICATION
THE PLACE FIT TO INSTALL:
o
C
Where there is burning, for example the unventilated kitchen,
carbarn or fireplace etc.
Near the fanner.
In damp place ,the alarm should be 3m at least away from jet
head in the bathroom or washing-dish machine.
o
Where the ambient temperature is low than 4 C or high than
38
, for example outdoor, unfinished attic.
In the disorderly and dirty place, you should make sure that
the washing-clothes room is clean then you can install the alarm.
In the very ventilated place, smoke will be spread completely.
Where jam appear, don’t jam the detection window. where is
beyond 305mm away from incadescent lamp or fluorescence
lamp, the electronic appliance’s noise will cause false alarm.
In air dead angle, like the ceiling corner in the diagram1
In the smoking meeting room, because smoke will cause
alarm very easily.
THE PLACE NOT FIT TO INSTALL:
CEILING
MINIMUM
10cm(4”)
M
IN
IM
U
M
1
0
c
m
(4
”)
M
A
X
M
U
M
3
0
.5
c
m
(1
2
”)
BEST HERE
NEVER HERE
ACCEPTABLE HERE
DIAGRAM 1
SIDE WALL
0.9m(3ft)
0.9m(3ft)
HORIZONTAL DISTANCE
FROM PEAK
DIAGRAM 2
ANYWGERE
IN THIS AREA
BEDROOM
BEDROOM
BEDROOM
KITCHEN
BEDROOM
LIVING ROOM
SINGLE FLOOR PLAN
SMOKE ALARM FOR MINIMUM PROTECTION
SMOKE ALARM FOR ADDITIONAL PROTECTION
MULTIPLE FLOOR PLAN
BEDROOM
BEDROOM
KITCHEN
BASEWENT