DSW108D
Smoke Alarm User’s Manual
DSW108D
are photoelectric smoke alarms, they are generally
more effective at detecting smoldering fires which smolder for
hours before bursting into flame. Sources of these fires may
include cigarettes burning in couches of bedding. DSW108D
accords with the ISO/DIS 12239 Standard.
IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT.
This user’s manual contains important information about your
smoke alarm’s operation. To insure your safety, you need install
one alarm at least in your every single room. Please don’t open
the smoke alarm for that may cause improper effect.
Related Power:
DC9V
AC110V
AC220V
Static Current:
<10uA
Alarm Current:
<10mA
Alarm Sonority:
85dB(3m)
Low Voltage Alarm:
6.5V
0.5V
o
o
Working Temperature:
-10 C~50 C
1. At first, you need install them in your bedroom and routeway,
and should install one item in every bedroom at least.
2. Stairway is important for you to rush out when fires occur, so
there must install smoke detectors.
3. You at least require one smoke alarm on every floor, including
finished attics and basements.
4. Install one alarm beside every electric facility.
5. Install smoke alarms in the middle of ceiling, because smog,
heat and flashes always lift to the top of rooms
6. If some reasons cause you can’t install them in the middle of
ceiling, you need to install them at least 10cm away from the
wall.
7. If you like to install them on the wall, they should be installed
10-30.5cm away under the ceiling. Diagram 1.
8. You need install more than one alarm when the length of your
hall exceeds 9m.
9. In an ablique roof room, install the alarm 0.9m away from the
top. Diagram 2.
10. How to install smoke alarms in a removable house. The
removable house is short of heat isolation, so you’d better install
the alarm 10-30.5cm away from the ceiling. for safety you need
install another one near your bedroom, too.
TECHNICAL PARAMETER
WHERE TO INSTALL SMOKE ALARMS
CEILING
MINIMUM
10cm(4”)
M
IN
IM
U
M
1
0
c
m
(4
”)
M
A
X
M
U
M
3
0
.5
c
m
(1
2
”)
BEST HERE
NEVER HERE
ACCEPTABLE HERE
DIAGRAM 1
SIDE WALL
0.9m(3ft)
0.9m(3ft)
HORIZONTAL DISTANCE
FROM PEAK
DIAGRAM 2
ANYWGERE
IN THIS AREA
1. Where combustion particles are produced. Combustion
particles form when something burns. Avoid installing in the
areas include poorly ventilated kitchens, garages, and furnace
rooms. Keep units at least 6m from the sources of combustion
particles(stove,furnace,water heater, space heater)if possible.
Ventilate these areas as much as possible.
2. In air streams near kitchens. Air currents can draw cooking
smoke into the sensing chamber of a smoke alarm near the
kitchen.
3. In very damp, humid or steamy areas, or directly near
bathrooms whith showers. Keep units at least 3m away from
showers saunas, dishwhashers, etc.
o
o
4. Where the temperatures are regularly below 40 F(4 C)or
o
above 100F(38 C),including unheated buildings, outdoor rooms,
porches, or unfinished attics or basements.
5. In very dusty, dirty, or greasy areas. Don’t install a smoke
alarm directly over the stove or range. Clean a laundry room
unit frequently to keep it free of dust or lint.
6. Near fresh air vents, ceiling fans, or in very drafty areas.
Drafts can blow smoke away from the unit, preventing it from
reaching the sensing chamber.
7. In insect infested areas. Insects can clog openings to the
sensing chamber and cause unwanted alarms.
8. Less than 305ram away from fluorescent lights. Electrical
“noise” can interfere with the sensor.
9. In “dead air” space, for example, in Diagram 1,near the
corner less than 10cm.
10. If you have a smoking meeting room, don’t install the alarm
there for the unit will alarm when several persons smoke;
Tools you will need:
* Pencil
* Drill with 6.5ram drill bit
* Standard/Flathead screwdrive
*Hammerr
WHERE NOT TO INSTALL SMOKE ALARMS
BEDROOM
BEDROOM
BEDROOM
KITCHEN
BEDROOM
LIVING ROOM
SINGLE FLOOR PLAN
SMOKE ALARM FOR MINIMUM PROTECTION
SMOKE ALARM FOR ADDITIONAL PROTECTION
MULTIPLE FLOOR PLAN
BEDROOM
BEDROOM
KITCHEN
BASEWENT
L
IV
IN
G
R
O
O
M
HOW TO INSTALL THIS SMOKE ALARM
1. Hold base firmly and push the hinge in then turn anti-
clockwise,so release the base down.
2. Hold the smoke alarm base against the ceiling (or wall) and
make a mark at the center of each of the mounting slots with a
pencil.
3. Place the unit where it won’t get covered with dust when you
drill the mounting holes.
4. Using a 6.5mm drill bit, drill a hole through each pencil mark
into 35mm deep.
5. Insert the plastic screw anchors into the holes and tap them
gently with a hammer. Tighten the 3*30 screws into the screw
anchors, then loosen them two turns.
6. Slide the smoke alarm base up to the screw heads end up in
the narrow ends of the mounting slots, then tighten the screws
completely.
7. Insert the 9V battery into the the box, make sure the red pry
is under the battery, so the battery is stable. Diagram 3.