7. light control(LUX) is adjustable
;
8. 2 remote controls are for your choice at will: remote controller(1) or remote controller(2)
on
:
the load work always.
off: 1) make the load stop working;
2) in normal mode, after convert to impulse mode, press it to return normal mode.
impulse: in normal mode press this key to convert to impulse mode;
Set time: set needed time, the details is in SET TIME
WAY.
Note:
1. during sensing, the emitter is ineffective.
2. loosen the off key, after 2sec, pressing other key is
effective.
SET TIME WAY
In normal mode set time-delay and in impulse mode set sense
time-interval.
1
.
50sec later after switching on power, the sensor enter working state; now you can start to set time;
2
.
Press and hold set-time button, LED numeric display number start to add from the right bit; like
following figure.
3
.
Loose set-time button and then within 2sec immediately press and hold button again, LED numeric
display number start to diminish from the right bit(like following figure)
4. Like above, you can repeat pressing button to make the adding and diminishing exchange, until the
number is needed.
Note:
1. to avoid false pressing, 2sec later after pressing and hold set time button, it start to set time.
2. After switch off power, the time you set previously will not be saved, it will resume default
time(normal mode:8sec, impulse mode:50sec)
3. during setting time, to make number adding and diminishing exchange, the interval between
loosing button and pressing it again should not exceed 2sec, otherwise the LED numeric will
display OFF, you must reset time from 0.
Example:
:
set time 25sec and then set to 10sec:
Step1: after sensor enter working state, press and hold set time button until LED numeric display 29,
loosen button (the number adding, LED numeric display 000’001…’009’019’029)
Step2: within 2sec immediately press and hold button again until LED numeric display 25sec, loosen