background image

DSPPA

MIXING AMPLIFIER

- 4 -

CONNECTIONS

(

without multi-zone outputs

)

1

2
3

4

CH4

CH1

CH3

CH2

CH5

CH6

SPEAKER OUTPUT

ZONE OUTPUT

 4-16Ω

~240V/50Hz/6A

MIN MAX

INPUT

MUTE

AUX1

AUX2

OUT

AUX3

MIC4 VOL

MIC3 VOL

5

2

1

3

0

4

10

9

8

7

6

5

2

1

3

0

4

10

9

8

7

6

FM ANTENA

FM(75? )

      Nur Sicherung 250V

Use Only With A 250V Fuse

Employer Unlquement Avec

         Fusible De 250V

MIC2

+

-

F4AL250V

COM 100V COM 100V COM 100V COM 100V COM 100V COM 100V

MIC3 IN

MIC4 IN

P

H

A

N

TO

M

M

IC

P

H

A

N

TO

M

M

IC

5

6

7

CONNECTIONS

(

with multi-zone outputs

)

8

9

10

11

CH4

CH1

CH3

CH2

CH5

CH6

SPEAKER OUTPUT

ZONE OUTPUT

 4-16Ω

~240V/50Hz/6A

MIN MAX

INPUT

MUTE

AUX1

AUX2

OUT

AUX3

MIC4 VOL

MIC3 VOL

5

2

1

3

0

4

10

9

8

7

6

5

2

1

3

0

4

10

9

8

7

6

FM ANTENA

FM(75? )

      Nur Sicherung 250V

Use Only With A 250V Fuse

Employer Unlquement Avec

         Fusible De 250V

MIC2

+

-

F4AL250V

COM 100V COM 100V COM 100V COM 100V COM 100V COM 100V

MIC3 IN

MIC4 IN

P

H

A

N

TO

M

M

IC

P

H

A

N

TO

M

M

IC

12
13

14

15

16

Note:

17

Individual zone opening and closing may be achieved by adjusting

Zone Volume Adjustment Button

on

18

Front Panel

.

19
20
21

MIC 3

MIC 4

Tuner, CD,

Cassette

Recorder or

another Amp.

To MIC 1 Input

Jack on Front Panel

MIC 1 with Priority

Input

MIC 2

Tuner, CD,

Cassette

Recorder or

another Amp.

MIC 1 with Priority

Input

To MIC 1 Input

Jack on Front Panel

MIC 2

MIC 3

MIC 4

Summary of Contents for MP1010U

Page 1: ...210U MP310U MP610U MP1010U 6 7 8 9 10 11 12 13 14 15 16 OWNER S MANUAL 17 18 Welcome to use the public address system manufactured For the better application of this 19 equipment please read the operation instruction carefully prior to use 20 ...

Page 2: ...CTIONS without multi zone outputs 4 7 CONNECTIONS with multi zone outputs 4 8 Instructions to Infrared Remote Controller 5 9 Operating Instructions 6 10 PRECAUTION OF INSTALLATION 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 ...

Page 3: ...e and selection of EQ mode and so on by 5 means of infrared remote control and selection USB SD 6 LED digital tube displaying volume playing status program number and so on 7 2MIC inputs 3AUX inputs and 1AUX output 8 4 16Ω rated output 9 6 zone output 10 Individual volume control and output level indication for each zone output 11 Mute function for priority input 12 Treble and Bass control 13 Chim...

Page 4: ... 9 Zone Level Indicator 29 10 Chime Button 30 11 MP3 SD Jack 31 12 MP3 tuner select key 32 13 MP3 tuner status operation key 33 14 MP3 tuner status operation key 34 15 MP3 tuner status operation key 35 16 MP3 USB Jack 36 17 MP3 tuner status display 37 18 Five unit LED Level Meter 38 39 Note 40 When all five units of the LED level meter remain lit it indicates that the sound is distorted In such ca...

Page 5: ...V COM 100V COM 100V COM 100V COM 100V COM 100V COM 100V MIC3 IN MIC4 IN PHANTOM MIC PHANTOM MIC 11 12 13 5 6 7 1 Mute control Button 8 2 MIC 2 Input Jack 9 3 AUX Input Jack 1 2 3 10 4 AUX Output Jack 11 Link with another amplifier or recording equipment 12 5 6 zone Output 13 6 AC Power Source Insert 14 7 Fan Exhaust Window 15 8 Speaker Output Terminal 16 9 AC Power Fuse 17 10 FM antenna Jack 18 11...

Page 6: ...R OUTPUT ZONE OUTPUT 4 16Ω 240V 50Hz 6A MIN MAX INPUT MUTE AUX1 AUX2 OUT AUX3 MIC4 VOL MIC3 VOL 5 2 1 3 0 4 10 9 8 7 6 5 2 1 3 0 4 10 9 8 7 6 FM ANTENA FM 75 Nur Sicherung 250V Use Only With A 250V Fuse Employer Unlquement Avec Fusible De 250V MIC2 F4AL250V COM 100V COM 100V COM 100V COM 100V COM 100V COM 100V MIC3 IN MIC4 IN PHANTOM MIC PHANTOM MIC 12 13 14 15 16 Note 17 Individual zone opening a...

Page 7: ...ction button radio 12 backward channel selection button 13 6 MP3 forward song selection button radio forward 14 channel selection button 15 7 EQ Under MP3 output mode with the Class mode Jazz mode Rock mode 16 Bass mode and Pop mode This button is also used for calling memorized channel by tuner 17 8 VOL MP3 TUNER volume decrease button 18 9 VOL MP3 TUNER volume increase button 19 10 0 9 numerical...

Page 8: ...he repeated playing of the current played chapter press button RPT again and LED will display 18 ALL indicating the repeated playing of all the chapters on the U disk 19 3 Selection of EQ mode MP3 in this machine has five 5 EQ modes including Class mode Jazz mode 20 Rock mode Bass mode and Pop mode It is allowed to select by use of the button EQ on the infrared remote 21 controller When pressing t...

Page 9: ...g of the 4 channel 5 2 Calling channel It is allowed to directly call and play the channels searched and memorized by automatic 6 search The buttons or on the panel are used to select forward and backward the memorizing 7 number to call the channel for play or the buttons or EQ on the infrared remote controller or the digital 8 keys from 0 9 to select the memorizing number to call the channel for ...

Page 10: ...ect sunlight 15 3 with high ambient temperature or adjacent to heat generating equipment 16 4 with high humidity or heavy dust 17 5 susceptible to vibration 18 3 Make sure the power outlet conforms to the plug of the unit 19 4 Do not use this unit if the electrical power cord is frayed or broken 20 5 Always operate the unit with the ground wire 21 6 If a short alarm rings after turning on power an...

Page 11: ...0Hz 16kHz 3dB Distortion Less than 1 at 1kHz 1 3 rated output voltage Ratio of Signal to Noise MIC more than 71dB LINE more than 85dB Tone Bass 10dB at 100Hz Treble 10dB at 10kHz Protection DC voltage overload short circuit Mute Input signals from MIC 1 override other input signals Power Requirements AC 220 240V 50 60Hz Power Consumption 120W 250W 500W 650W Outer Packing Size mm L W H 520 430 195 ...

Page 12: ...do not remove the cover Please contact us or authorized dealers for servicing The symbol on rear panel indicates hazardous live The connection of these terminals must be operated by the instructed person The unit connect to the mains by the plug Pull out the plug when the unit is in fault or danger status So the socket for the unit plugging must be set in the place can be easy to plug into and pul...

Reviews: