background image

 

5

PRECAUTION OF INSTALLATION 
 

1. 

Do not block ventilation holes. 

2. The amplifier should not be placed in any of the areas: 

1) with poor ventilation; 

2) exposed to direct sunlight; 

3) with high ambient temperature or adjacent to heat-generating equipment; 

4) with high humidity or heavy dust; 

5) susceptible to vibration. 

3. Make sure the power outlet conforms to the plug of the unit. 

4. Do not use this unit if the electrical power cord is frayed or broken. 

5. Always operate the unit with the ground wire   

6.  If  a  short  alarm  rings  after  turning  on  power  and  inputting  signals,  there  must  be  an 

output short circuit fault. In such case, power should be cut off immediately.    Do not turn 

on the power until the fault is removed. 

Summary of Contents for MP 200P II

Page 1: ...WNER S MANUAL Before operating please read this manual carefully FEATURES l Three Mic inputs two Aux inputs and one Aux output for link l Transformer with 100V 70V rated power and 4 ohms rated resistance output balanced no ground l Mic 1 with muting function for making a broadcast with the highest level of priority l Individual volume control for each channel l Bass and treble tone control l A fiv...

Page 2: ...lanced 30 600Ω with 1 4 phone plug The muting function is activated while the signal is sent to Mic Note When all five elements of the LED level meter remain lit it indicates that the sound is distorted In such case adjusting each volume control button until LED element 4 8dB and LED element 5 10dB flash REAR PANEL COM 4 16Ω 70V 100V CAITION RISK OF ELECTRIC SHOCK DO NOT OPEN AC 220V 50Hz MIC2 MIC...

Page 3: ...d source equipment 5 AUX output Connecting to amplifier 6 Output terminals Connecting to speakers 7 Mute control Adjusting muting grade Note It is better to only use one pair of output terminals when connecting this unit to speakers ...

Page 4: ... 8 9 7 4 MIC1 MP 200PⅡ EXPLANATIONS OF MUTING FUNCTION Mic 1 input has the highest level of priority as the signal inputting to Mic 1 can override other input signals The grade of this muting function can be adjusted within the range from 0 dB to 30 dB by adjusting MUTE control button on the rear panel It is preset at 30 dB before leaving factory PRIORITY MIC 100V COM AUX OUT AUX2 AUX1 MIC3 MIC2 D...

Page 5: ...h high humidity or heavy dust 5 susceptible to vibration 3 Make sure the power outlet conforms to the plug of the unit 4 Do not use this unit if the electrical power cord is frayed or broken 5 Always operate the unit with the ground wire 6 If a short alarm rings after turning on power and inputting signals there must be an output short circuit fault In such case power should be cut off immediately...

Page 6: ...0 dB at 100 Hz Tone Treble 10 dB at 10 kHz Protection AC fuse DC voltage overload short circuit Muting function Mic 1 overrides other input signals with 0 30 dB attenuation Power requirements AC 220 240 V 50 60 Hz Power consumption 120W 250W Dimensions 418 345 88 mm Gross weight 11 5 kg 12 5 kg Net weight 10 kg 11 kg Specifications are subject to change without notice CAUTION When the Power switch...