Network PA System On-Demand Terminal

4

4. Dimension

5. Connection

The On-demand terminal and the Output only terminal can be connected by the network cable.

The network cable and the 8-pin cable should be connected as below:

Note: One end of the 8-pin port plug is connected to the socket on the rear of the on-demand terminal, the
other end to the network terminal.

The wiring method to the network terminal is as shown below. Plug the green terminal into the color
on-demand terminal connection port of the network terminal, and then connect the network cable to
the corresponding green terminal.

Dimension of the front panel

Dimension of the package box

Inlet hole

橙白

绿

绿白

8

7

6

5

4

3

2

1

蓝白

棕白

棕 - 棕白

橙 - 橙白

蓝白

8

7

6

5

4

3

2

1

8位网口插头

8. Brown

7. Brown/white

6. Orange

5. Blue/white

4. Blue

3. Orange/white

2. Green

1. Green/white

8-pin port plug

8. Empty

7. Empty

6. Empty

5. Empty

4. Brown-Brown/white

3. Orange-Orange/white

2. Blue/white

1. Blue

On-demand terminal

Summary of Contents for MAG6402

Page 1: ...A System On Demand Terminal MAG6402 Directions for Use Thank you for choosing DSPPA PA System To ensure better use of the equipment please read this manual carefully before usage Guangzhou DSPPA Audio...

Page 2: ...chnical indicators of the product and other contents of the Network PA System On Demand Terminal Prior to connection installation and use the user shall carefully read the instructions and conduct ope...

Page 3: ...terminal can also accept paging from other zones and the override of host emergency broadcast Can receive infrared remote control operation With screen protection function for energy saving 2 Appearan...

Page 4: ...As shown below you can dial the terminal number for zone paging Enter the terminal number and click the Paging button in the lower right corner of the interface to start paging The interface also dis...

Page 5: ...paging broadcast a prominent telephone paging prompt box will pop up automatically on the display screen of the paged broadcast zone 4 When the on demand terminal receives a paging signal from the ho...

Page 6: ...minal The wiring method to the network terminal is as shown below Plug the green terminal into the color on demand terminal connection port of the network terminal and then connect the network cable t...

Page 7: ...minal the brown cable corresponds to terminal B the blue and blue white cables correspond to COM terminal and the orange and orange white cables corresponds to voltage terminal 12V 14V Green terminal...

Page 8: ...fixed on the box from the bottom by screws please make sure that the two screw holes should be align with the bottom edge of the box Installation Steps Step one Connect with the host Step two Finish...

Page 9: ...320 240 3 2inch True Color Screen Dimension mm 86 86 10 Base not included Net Weight 110g Including Installation Box Item Index Input Voltage DC24V Input Current 24V 100mA Power Consumption 3W Standby...

Page 10: ...n the machine cover plate at discretion so as to prevent electric shock The professional with professional certificate shall conduct repair if necessary The terminal marked with symbol in the equipmen...

Reviews: