A/V All in One Intelligent Host
4
6) Support open, control, and open degree of curtains.
3.7 Fire broadcast
1) Support 32-channel fire signal of fire alarm machine;
2) IP communication, easy to deploy;
3) Extendable to 32 fire alarm machines;
4) Support audio fire broadcast and video fire broadcast.
3.8 Remote control of broadcast
1) Support 100m remote control;
2) Support audio broadcast, video broadcast and fire drill broadcast.
3.9 Priority level
1) Priority level could be changed by software;
2) Default priority is as follows:
NO
Business
Priority
level
Note
1
Fire broadcast
0
Highest level, could interrupt other broadcast
2
A/V broadcast
3
Background broadcast, could continue to play
after being interrupted
3
Paging business
1
Business broadcast, could interrupt other
business with lower priority level and continue
to restore previous business after paging.
4
A/V live
2
Business broadcast, could be interrupted by fire
broadcast and paging broadcast, and could
restore after being interrupted