AD1200 Installer Manual, Rev. 19.06.2013                                     5                                                               

www.dsp-technology.com

 

2.09  Programming Dial Cycles 

After the dialer has dialed, it can be programmed to give an audible or visual indication. Audio 
indication is given by the internal buzzer sounding once dialing has been completed and visual 
indication is given on the seven segment display                to enabled this function:  

Press:  PROG 

Press: 

Visual  or 

Buzzer 

2.08  Programming Audible Alert After Alarm Dialling 

After dialing all programmed numbers, the dialer can repeat the dialing process up to 3 times. 
Therefore the total amount of dial cycles may be programmed. The default setting is 2.  

Press: 

or 

 3                  4 

2.11  Programming Entry Exit Timing 

The AD1200 provides the possibility to assign an Entry Exit Timing to the Signal Input. This en-
ables the user directly connect detectors (e.g. motion or smoke detectors) to the signal input. In 
this case the AD1200 acts like a small independent alarm panel. 
 
Programming a value of 0 will disable this feature (default). 
 
Programming values from 1 … 9 correspond to Entry / Exit Times of 10 … 90 seconds. 

PROG 

Press: 

 
If an Entry Exit time greater than 0 is programmed then the system will act as following: 
 
1.) After the user leaves the User Mode the system will start the Exit Timer. The system indicates 
the user with beeps that he should leave the premises. Within this time any signal from the input is 
masked. No dial attempt will be initiated. 
 
2.) After the user left the premises the system waits for any signal on the input. 
 
3.) If there is a signal on the input then the system will start the Entry Timer. Again the system 
indicates the user with beeps to disarm the system with his User Code. While this time no dial 
attempt will be initiated. 
 
4.) If the User enters the User Code correctly the system will be disarmed. 
 
5.) If the User does not manage to enter the User code in time the system will initiate an alarm 
condition and start the first dial attempt. 

2.10  Programming Alarm Input 

There is a option of 2 ways to trigger the dialer either by applying 12Vdc or 0Vdc. The default 
setting is 12Vdc.  To change the trigger input:   

Press: 

12Vdc  or 

0Vdc  

PROG 

Press: 

or 

or 

Press: 

or key up to 

 9                   

PROG 

Press: 

Summary of Contents for AD1200

Page 1: ...AD1200 ...

Page 2: ...ller Test Mode Enabling and Disabling of Remote Device Functionality NEW FEATURE Recording and new Remote Device NEW FEATURE Deleting a Remote Device NEW FEATURE Deleting all eight Remote Devices NEW FEATURE Setting Remote Device Type NEW FEATURE Reset All Programmable Locations to Factory Default Hardware Reset to Factory Default Settings User Mode User Programming Entering User Programming Chang...

Page 3: ...nd voice data are saved Performs tone pulse and also through PABX system dialling with multiple attempts Telephone numbers programmed can be recalled for display Programmable telephone delay time for each telephone number Single voice message up to 20 seconds and programmable Entry Exit Timing Lightning protection at telephone line input Optional Remote Device functionality for Panic Alarm Arming ...

Page 4: ...d Set Telephone Hand Set Green Set Telephone Hand Set Red ST6100 ST6600 ST6000 ST6500 other Panels 12V 12V 12V 12V INP INP SET SET SET SET LINE LINE LINE LINE AUX 1 S AUX S BELL EARTH EARTH Note If you are not using the S on the ST6100 ST6600 you can enter engineer programming in those control panels and change the Switch Positive to 0V If a secure zone is activated in the ST6100 or ST6600 the Dia...

Page 5: ...tarts blinking you are now in installer programming mode 2 02 Programming New Installer Code Press Enter new 4 digit code 2 03 Recall New Installer Code Press 2 04 Burn In Installer Code 2 05 Setting Pulse or Tone Dialling Press 2 06 Operating Through PABX If the AD1200 has to call through a PABX system Program in this location the telephone number which obtains an outside line The dialer will wai...

Page 6: ...e default Programming values from 1 9 correspond to Entry Exit Times of 10 90 seconds PROG 0 5 Press If an Entry Exit time greater than 0 is programmed then the system will act as following 1 After the user leaves the User Mode the system will start the Exit Timer The system indicates the user with beeps that he should leave the premises Within this time any signal from the input is masked No dial...

Page 7: ...Telephone Numbers Programmed telephone numbers can be recalled and displayed on the seven segment display Press READ PROG Enter telephone number location 2 15 Deleting A Telephone Number Press PROG Enter telephone number location ENTER 2 16 Deleting All Telephone Numbers Press PROG 1 9 Press 2 17 Recording Voice Message The voice message recoding duration is 20 seconds The microphone is located be...

Page 8: ...e device and link it to the AD1200 Note If the selected location already contains another Remote Device the current location must be deleted first refer to 2 23 before linking a new device is possible at this location Press Press 2 23 Deleting a Remote Device To delete a Remote Device follow the following procedure 2 24 Deleting all eight Remote Devices Press PROG 0 8 1 To disable the feature the ...

Page 9: ...ll invalidate you warranty Every effort has been made to provide accurate information however slight variations can occur We reserve the right to make changes for the product improvement at anytime 2 25 Setting Remote Device Type Each of the eight Remote Devices may be setup to one of the following different functionalities Remote Panic Button Type Code 1 Remote Arming Type Code 2 Remote Disarming...

Page 10: ... ENTER PWR LED extinguished Programming can only be done when the unit is in off mode This is indicated by the PWR LED extinguished The dialer will exit user programming if no data entering after 2 minutes If the PWR LED is on after entering user code re enter the user code again Acceptance of programming is given by 6 short beeps from the buzzer error tone is indicted by a long beep Enter new tel...

Page 11: ... activated Off mode is indicated by the PWR LED extinguished 4 02 Activating Silent Alarm operational in Standby as well as in Off Mode Enter user code ENTER Power LED extinguished You can return to standby mode by repeated above sequence 4 01 Switching Off or Switching to Standby Mode Press PROG ENTER simultaneous to activate Silent Alarm Panic Alarm 4 03 Alarm Memory If AD1200 has activated in S...

Page 12: ...n Number Clear Installer Code Burn In Clear Dialer Memory Audible Disabled Alarm Trigger Input 12 Volts Telephone No 1 Clear Telephone No 2 Clear Telephone No 3 Clear Telephone No 4 Clear Telephone No 5 Clear Telephone No 6 Clear Telephone No 7 Clear Telephone No 8 Clear Slow Dialing Telephone Num Clear Dial Cycles 2 Entry Exit Time 0 OFF Recorded Message Installer Information Installer Name Addre...

Reviews: