![DSP AD1200 Instruction Download Page 4](http://html.mh-extra.com/html/dsp/ad1200/ad1200_instruction_2535211004.webp)
AD1200 Installer Manual, Rev. 19.06.2013 3
www.dsp-technology.com
1.04 Wiring Terminals
1.05 Wiring Diagram AD1200 to ST6100, ST6500 & ST6600 and other Panels
Terminal
Connection
Suggested Wire Colour
Trigger
Trigger 0V or 12Vdc
Blue
0Vdc -
Negative Supply (OV)
Black
12Vdc +
Positive Supply (12+)
Red
Line In
Telephone Line In
Green
Earth
Ground/Earth Wire
Yellow
Line In
Telephone Line In
Red
Set
Telephone Hand Set
Green
Set
Telephone Hand Set
Red
ST6100 & ST6600
ST6000 & ST6500 & other Panels
+ 12V
+ 12V
- 12V
- 12V
INP
INP
SET
SET
SET
SET
LINE
LINE
LINE
LINE
AUX 1 S
+
+
AUX S BELL
+
+
+
EARTH
EARTH
Note:
If you are not using the S+ on the ST6100 & ST6600, you can enter engineer programming in
those control panels and change the Switch Positive to 0V. If a secure zone is activated in the
ST6100 or ST6600 the Dialer will dial the programmed numbers. The alarm trigger must be
programmed as 12Vdc.
Enter engineering programming in the ST6100 & ST6600:
Press: 5
Press: 9 Day LED Flashing = 0V
Press: Reset
Summary of Contents for AD1200