DSM Delvotest Fast Go Max User Manual Download Page 11

 

-

 

  10 - 

2.2.

 

Installation Methods 

 

CAUTION: Install this system on a flat surface. Be cautious with connection 
of AC/DC adapter.

 

 

  Product Connection 

(ⅰ) Connect AC/DC adapter to the Delvotest® Fast Go Max

(ⅱ) 

Connect power cable to AC/DC adapter. 

(ⅲ) 

Put the plug in the 100-240V socket. 

 

  Powering On / Off 

 

[Figure 2.2] Rear Panel

 

 

T

he power button is located on the top panel of the Delvotest® Fast Go Max

After approximately one second of pressing and holding the power button, the DSM log
o appears and begins the program. Although it is advisable to use the power button on 
the program to exit the reader, if the reader has a problem, push and hold the power bu
tton for more than 4 seconds to force the reader to power down. 

Summary of Contents for Delvotest Fast Go Max

Page 1: ...User Manual Delvotest Fast Go Max DSM Alexander Fleminglaan 1 2613 AX Delft The Netherlands...

Page 2: ...omponents 9 2 2 Installation Methods 10 3 Running Delvotest Fast Go Max 12 3 1 Instrument Registration 12 3 2 Supervisor Registration 13 3 3 Log In 14 3 4 Main Menu 15 3 5 Test Mode 16 3 6 Test Result...

Page 3: ...ss of property please read instructions and safety guidelines in this user manual and be well informed before using this reader Always have this user manual at hand in case of need Effective version 1...

Page 4: ...uct The serial number of this product To indicate the manufacturer Biohazard To indicate that biological substances may damage your health Warning To indicate that a user should read and consult accom...

Page 5: ...wer LED to see if it is working properly If the system does not turn on check the condition of the connector To run the program and functions of this reader follow test procedures guided in this user...

Page 6: ...oise is prohibited The Calibrator may be discolored under direct sunlight It is recommended that the calibrator is stored in a dark place Be careful not to extremely tilt or drop the reader during tra...

Page 7: ...tion affecting the system during the test abort the process and restart the test from the beginning Do not open the tray during the test If the device is exposed to the outside during the test abort t...

Page 8: ...f this product can be changed due to company s action for improving convenience and product performance You may not be compensated if it is not mentioned by manufacturer Any problem occurred by not us...

Page 9: ...s through highly sensitive image analysis based on LED and the high quality image sensor Convenient management of patient information is also possible by saving and transporting patient information th...

Page 10: ...e product package are as following Figure 2 1 Product Components Product and parts composition of Delvotest Fast Go Max AC DC Adapter 12V 5A output Power Cable Touch Pen Calibrator for QC purpose only...

Page 11: ...100 240V socket Powering On Off Figure 2 2 Rear Panel The power button is located on the top panel of the Delvotest Fast Go Max After approximately one second of pressing and holding the power button...

Page 12: ...Operating Mode RED Powered on and fully charged Adapter Operating Mode RED Powered on Battery Operating Mode BLUE The measurement is in progress Battery Operating Mode The lithium polymer battery is...

Page 13: ...e analyzer is first booted It will not be displayed after registered Serial Number Name and Country are required and you do not need to enter anything else If the registration is successful the messag...

Page 14: ...gistration Page Supervisor Registration is displayed at the first time after analyzer registered It is not displayed after Supervisor registered ID Password and Confirm PW are mandatory fields If Supe...

Page 15: ...n screen If the ID is not registered or the Password is incorrect an error message is displayed Click the bottom left button to display the Program Information window Figure 3 4 Program Information Wh...

Page 16: ...in Menu Figure 3 5 Main Menu Menu Description Test Mode Measurement mode Test Reports Manage test results Review Export Backup Manager Manage Operators Samples and Test Files Add Remove Modify Instr C...

Page 17: ...nding Kit Lot Number and CutOff values By clicking the Button you can search and input the sample ID already registered in the Sample list Select the ID you want to enter as shown in the image below a...

Page 18: ...s shown in the image below Figure 3 8 Test Result Page Click the button and the result will be output to the built in printer If you click the button you can export the result as a PDF file by E Mail...

Page 19: ...as PDF screen will be displayed as shown below Enter the File Name and click the button then a PDF file will be saved in the ResultPDF folder of the USB memory Figure 3 11 Export as PDF Click the butt...

Page 20: ...f you update the analyzer from the earlier versions please click Rebuild Database button to regenerate test results database The first time you enter this screen after updating to version 1 0 9 or lat...

Page 21: ...in the date field Clicking the button will filter the results in the list mode is a mode where you select only one result from the list and you can change it to mode by toggling the Button mode is a...

Page 22: ...Figure 3 14 Result Review Page Export The selected results are exported to a CSV Excel File Backup PDF to USB Figure 3 15 Export Results Delete Deletes the selected results permanently from the analy...

Page 23: ...amples Test Files from Manager screen Figure 3 16 Manager Select Page A Operator Figure 3 17 Operator Manager Page New Register a new Operator ID Password and Confirm PW are required fields Authority...

Page 24: ...Registration Page Modify You can modify the password and information of the selected operator from the list ID cannot be changed Figure 3 19 Operator Modification Page Delete You can delete the select...

Page 25: ...ew Register a Sample ID is required and you do not need to enter anything else Gender can select Female and Male Figure 3 21 Sample Registration Page Modify You can modify the information of the selec...

Page 26: ...ected sample from the list C Test Files You can view and manage the information in the Test file Figure 3 23 Test File Manager Page Test File Viewer Select a test file in the Instrument list and click...

Page 27: ...import into the analyzer When you click the button the selected test files are imported from the USB storage into the analyzer Export Select test files in the Instrument list to export to the USB sto...

Page 28: ...27 Remove If you click the Remove Test button after selecting the test files in the Instrument list the selected Test files are deleted permanently from the analyzer...

Page 29: ...nsert the Reference cassette and click the Run button to start the Instrument Check When the check is completed it moves to the result page where the Pass image is displayed when there is no problem i...

Page 30: ...reen select the item you want to review and click the View button The check result is displayed as shown below Figure 3 29 Instrument Check Result Export In the Instrument Check screen you can export...

Page 31: ...product If you have used all the paper you need to replace it with a new one follow the procedures below The thermal printer is located on the back of the analyzer Press the button attached to the pri...

Page 32: ...Pull the end of the print paper out of the case by inserting it into the slot of the case from inside so that the print paper is easily released Press firmly the case of the thermal printer to close...

Page 33: ...ch Screen Supported Accessories Barcode reader Keyboard Mouse USB Memory Optional Patient Records 10 000 Patients Input Voltage 12 VDC Power Consumption 12W Dimension W x H x D 300 mm x 186 mm x 210 m...

Page 34: ...t After sales Service Check list before After sales Service Product name and model Purchase year free or charged Symptoms details Requirements in After sales Service Place user name user contact Produ...