5. Troubleshooting
Following are a few common problems that may occur during operation. Here
are some suggestions for easy troubleshooting:
A. The unit does not work, no light and fan.
1. Check the connection of power and main fuse.
2. Measure the main voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller.
1. DMX LED should be on. If not, check DMX connectors, cables to see if
connected properly.
2. If the DMX LED is on and no response to the channel, check the address
settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors
or on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables
that may cause damage or interference to DMX interface circuit.