DSE DSE2157 Installation Instructions Manual Download Page 15

®

DSE

Genset

SPECIFICATION

DEEP SEA ELECTRONICS PLC UK

Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH

TELEPHONE

+44 (0) 1723 890099

FACSIMILE 

+44 (0) 1723 893303

EMAIL

[email protected]  

WEBSITE

www.deepseaplc.com

DEEP SEA ELECTRONICS INC USA

3230 Williams Avenue, Rockford, IL 61101-2668 USA

TELEPHONE

+1 (815) 316 8706

FACSIMILE 

+1 (815) 316 8708

EMAIL

[email protected]  

WEBSITE 

www.deepseausa.com

055-061/10/10 (3) US

Registered in England & Wales No.01319649
VAT No.316923457

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change
the details shown on this data sheet without prior notice. The contents are intended for guidance only.

DSE

2157

DSE

NET

®

OUTPUT EXPANSION MODULE

KEY FEATURES

Power On/Link Lost LED ID
SWITCH

10 expansion modules can be
connected to 1 host controller at
a time

8 configurable relay contacts
with LED indicators:

- 4 Normally Open (N/O)
- 4 Change Over (C/O)

Terminal strip connection for
quick and easy set-up

ID SWITCH

The rotary ID switch is used to
select the address of the DSE2157
expansion module, as the host
control module is capable of giving
instructions to a number of
DSE2157 expansion modules at
the same time.

DC SUPPLY

CONTINUOUS VOLTAGE RATING

8 V to 35 V Continuous

CRANKING DROPOUTS

Able to survive 0 V for 50 mS, providing 
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
batteries. LEDs and backlight will not be
maintained during cranking.

MAXIMUM OPERATING CURRENT

325 mA at 12 V, 152 mA at 24 V

MAXIMUM STANDBY CURRENT

70 mA at 12 V, 32 mA at 24 V

AUXILIARY RELAY CONTACTS

2 Amp DC rated voltage free

DIMENSIONS

OVERALL

165 mm x 76 mm x 49 mm 
6.5” x 3” x 1.9”

RELATED MATERIALS

TITLE

PART NO’S

DSE2157 Installation Instructions                                                                              053-034

DSE2157 Operator Manual                                                                                        057-083

Summary of Contents for DSE2157

Page 1: ...D switch is used to select the ID of the 2157 expansion module as the host controller is capable of giving instructions to a number of 2157 expansion modules at the same time consult relevant modules...

Page 2: ...e centres 152 37mm x 64 50mm 6 00 x 2 54 Deep Sea Electronics Plc Tel 44 0 1723 890099 Fax 44 0 1723 893303 LO CALL from UK BT landlines Telephone 0845 260 8900 Email sales deepseaplc com Web www deep...

Page 3: ...DEEP SEA ELECTRONICS DSEEXTRA DSE2157 relay output expansion module 057 083 Author Anthony Manton COMPLEX SOLUTIONS MADE SIMPLE...

Page 4: ...ermission of the copyright holder except in accordance with the provisions of the Copyright Designs and Patents Act 1988 Applications for the copyright holder s written permission to reproduce any par...

Page 5: ...ONS 6 3 5 APPLICABLE STANDARDS 6 4 INSTALLATION 7 5 USER CONNECTIONS 7 5 1 TERMINAL SPECIFICATION 7 5 1 1 CONNECTOR A 7 5 1 2 CONNECTOR B 7 6 TYPICAL WIRING DIAGRAM 8 7 CONTROLS AND INDICATIONS 9 7 1...

Page 6: ...e life of the product If the product is passed or supplied to another party ensure that this document is passed to them for reference purposes This is not a controlled document You will not be automat...

Page 7: ...ion module s and must not be connect to any device other than DSE equipment designed for connection to the DSEnet Cable type Two core screened twisted pair Cable characteristic impedance 120 Recommend...

Page 8: ...essential information BS 4884 2 1993 This document conforms to BS4884 2 1993 Guide to content BS 4884 3 1993 This document conforms to BS4884 3 1993 Guide to presentation BS EN 60068 2 1 Minimum temp...

Page 9: ...mm AWG 18 3 Screen DSEnet only Do not connect to earh 4 A 0 5mm AWG 20 DSEnet only 5 B 0 5mm AWG 20 DSEnet only 5 1 2 CONNECTOR B Terminal Function Recommended size 6 Relay 1 1 0mm AWG 18 Normally ope...

Page 10: ...DSE2157 relay output expansion module 8 057 083 Issue 1 DSE2157 relay output expansion operator manual 6 TYPICAL WIRING DIAGRAM...

Page 11: ...le as the host controller is capable of giving instructions to a number of 2157 expansion modules at the same time consult relevant modules instructions for further details on number of supported expa...

Page 12: ...equipment purchaser at the point of sale For full details of any applicable warranty you are referred to your original equipment supplier OEM 11 DISPOSAL 11 1 WEEE WASTE ELECTRICAL AND ELECTRONIC EQUI...

Page 13: ...ODULE ISSUE 3 HOST MODULE 1 1 DSENET EXPANSION DC POWER SUPPLY 8 35V 7 OTHER DSE2157 VOLT FREE NORMALLY OPEN OUTPUTS VOLT FREE CHANGE OVER OUTPUTS DSENET 2157 2130 2510 20 2548 4 4 COMPATIBLE WITH DSE...

Page 14: ...y Standard for the Industrial Environment BS EN 61000 6 4 EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment includin...

Page 15: ...to 1 host controller at a time 8 configurable relay contacts with LED indicators 4 Normally Open N O 4 Change Over C O Terminal strip connection for quick and easy set up ID SWITCH The rotary ID switc...