7  CONTROLS AND INDICATIONS 

 

 

7.1  LED INDICATIONS 

 

Function 

Colour 

Action 

Power on / Link lost 

RED 

Steady when DC supply is connected and data is being received 
from the host controller. 
Flashing when the DC supply is connected and the data connection 
to the host controller is not operating. 

Status 1-8 

RED 

Lit when the corresponding relay is active 

 

7.2  ID SWITCH 

 
The rotary ID switch is used to select the ‘ID’ of the 2157 expansion module as the host controller is 
capable of giving instructions to a number of 2157 expansion modules at the same time (consult 
relevant modules instructions for further details on number of supported expansion units). 
 
The enclosure cover must be unclipped and removed to gain access to the switch. The switch should 
be operated using a small screwdriver and set to match the required ID. 
 

NOTE  :  The  ID  must  be  a  unique  number,  different  from  the  ID  of  any  other  2157  module 
connected to the host controller. 
If  two  or  more  2157  controllers  are  required  to  ‘mimic’  each  other  then  they  should  be 
configured with different IDs, and both configured the same in the host controller. 

 
 
 

 

Address Switch 

Power on / 
Link lost LED 

8 x Status LED  
(1 LED per 
relay) 

Summary of Contents for DSE2157

Page 1: ...D switch is used to select the ID of the 2157 expansion module as the host controller is capable of giving instructions to a number of 2157 expansion modules at the same time consult relevant modules...

Page 2: ...e centres 152 37mm x 64 50mm 6 00 x 2 54 Deep Sea Electronics Plc Tel 44 0 1723 890099 Fax 44 0 1723 893303 LO CALL from UK BT landlines Telephone 0845 260 8900 Email sales deepseaplc com Web www deep...

Page 3: ...DEEP SEA ELECTRONICS DSEEXTRA DSE2157 relay output expansion module 057 083 Author Anthony Manton COMPLEX SOLUTIONS MADE SIMPLE...

Page 4: ...ermission of the copyright holder except in accordance with the provisions of the Copyright Designs and Patents Act 1988 Applications for the copyright holder s written permission to reproduce any par...

Page 5: ...ONS 6 3 5 APPLICABLE STANDARDS 6 4 INSTALLATION 7 5 USER CONNECTIONS 7 5 1 TERMINAL SPECIFICATION 7 5 1 1 CONNECTOR A 7 5 1 2 CONNECTOR B 7 6 TYPICAL WIRING DIAGRAM 8 7 CONTROLS AND INDICATIONS 9 7 1...

Page 6: ...e life of the product If the product is passed or supplied to another party ensure that this document is passed to them for reference purposes This is not a controlled document You will not be automat...

Page 7: ...ion module s and must not be connect to any device other than DSE equipment designed for connection to the DSEnet Cable type Two core screened twisted pair Cable characteristic impedance 120 Recommend...

Page 8: ...essential information BS 4884 2 1993 This document conforms to BS4884 2 1993 Guide to content BS 4884 3 1993 This document conforms to BS4884 3 1993 Guide to presentation BS EN 60068 2 1 Minimum temp...

Page 9: ...mm AWG 18 3 Screen DSEnet only Do not connect to earh 4 A 0 5mm AWG 20 DSEnet only 5 B 0 5mm AWG 20 DSEnet only 5 1 2 CONNECTOR B Terminal Function Recommended size 6 Relay 1 1 0mm AWG 18 Normally ope...

Page 10: ...DSE2157 relay output expansion module 8 057 083 Issue 1 DSE2157 relay output expansion operator manual 6 TYPICAL WIRING DIAGRAM...

Page 11: ...le as the host controller is capable of giving instructions to a number of 2157 expansion modules at the same time consult relevant modules instructions for further details on number of supported expa...

Page 12: ...equipment purchaser at the point of sale For full details of any applicable warranty you are referred to your original equipment supplier OEM 11 DISPOSAL 11 1 WEEE WASTE ELECTRICAL AND ELECTRONIC EQUI...

Page 13: ...ODULE ISSUE 3 HOST MODULE 1 1 DSENET EXPANSION DC POWER SUPPLY 8 35V 7 OTHER DSE2157 VOLT FREE NORMALLY OPEN OUTPUTS VOLT FREE CHANGE OVER OUTPUTS DSENET 2157 2130 2510 20 2548 4 4 COMPATIBLE WITH DSE...

Page 14: ...y Standard for the Industrial Environment BS EN 61000 6 4 EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment includin...

Page 15: ...to 1 host controller at a time 8 configurable relay contacts with LED indicators 4 Normally Open N O 4 Change Over C O Terminal strip connection for quick and easy set up ID SWITCH The rotary ID switc...

Reviews: