s y s t e m p r o g r a m m i n g
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Entry Delay 1 and 2 (System Times) ............................................. Section [005]
Exit Delay (System Times) ............................................................. Section [005]
Audible Exit Delay with Urgency .................................. Section [014], Option [6]
Bell Squawk Options ...................................................................... Section [014]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Exit Delay Termination .................................................. Section [014], Option [7]
6.8
Lockout
The panel can be programmed to ‘lockout’ if a number of incorrect user code entries are made. After the
Number of Invalid Codes Before Lockout
has been reached the panel will lock out the keys for the
Lockout
Duration
and log the event to the event buffer. For the duration of the lockout the panel will sound an error
tone when any key is pressed.
Lockout will reset every hour.
To disable Lockout program the
Number of Invalid Codes Before Lockout
as [000].
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Number of Invalid Codes Before Lockout ...................................... Section [012]
Lockout Duration ............................................................................ Section [012]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Lockout Reporting Code ................................................................ Section [338]
6.9
Swinger Shutdown
The swinger shutdown feature is designed to prevent a “runaway” communicator from tying up the central
station. After the panel has communicated the programmed number of transmissions for an event, it will no
longer report that event until the swinger shutdown is reset. Different swinger shutdown levels can be set for
zone alarms, zone tampers and maintenance signals.
By default, each
Swinger Shutdown
limit is set to [003]. The panel will not send more than three signals for
each zone until the swinger shutdown is reset.
Swinger shutdown will be reset every day at midnight or when the panel is armed. Once reset, the panel will
again communicate normally.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Swinger Shutdown .......................................................................... Section [370]
6.10
International Programming Options
[701] First International Option Code
1.
Power Line Frequency
: 50Hz/60Hz
2 - 8
For Future Use
[702] Second International Option Code
1.
International Dialing Parameters
: The pulse dialing Make/Break ratio is 33/67.
North American Dialing Parameters
: The pulse dialing Make/Break ratio is 40/60.
Contact your local telephone company to confirm which setting should be used.
2.
Force Dialing Enabled
: If the panel fails to call the monitoring station on the first dialing attempt, on every
attempt thereafter the panel will dial out with or without the presence of dial tone.
Force Dialing Disabled
: The panel will not dial out if dial tone is not detected.
3.
Land Line Test Transmission in Minutes/Days
: This option allows you to select whether the Land Line
Test Transmission cycle will be counted in minutes or days. The Test Transmission cycle is programmed in
Section [370].
4 - 8
For Future Use
6.11
[
✱
] Commands
[
✱
]+[1]
Zone Bypass/Reactivate Stay/Away Zones
The [
✱
] [1] command can be used to bypass individual zones. It can be used if the user wants to have access
to an area while the system is armed or to bypass a defective zone (bad contact, damaged wiring) until
service can be provided.
The system can be armed with a bypassed zone. A bypassed zone will not cause an alarm.
If
Code Required for Bypass
is enabled an access code will be required to enter the Bypass mode. Only user
codes with the Bypass attribute enabled will be able to bypass zones.
Zones can only be bypassed when the system is disarmed.