7
c o m m u n i c a t i o n s p r o g r a m m i n g
Zone Alarm
The panel will transmit the
Zone Alarm
Reporting Code when a zone goes into alarm. 24 hour type zones will
go into alarm whether the panel is armed or disarmed and report to the central station. All other types of zones
will only go into alarm if the panel is armed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone Alarm Reporting Codes ........................................................ Section [320]
Zone Restoral
If the
Restoral on Bell Time-out
option is selected, the panel will send the
Zone Restoral
Reporting Code for
the zone if the bell cut-off time has expired
and the zone is secured. If the zone is not secured when the alarm
output times out, the panel will send the restoral immediately once the zone is secured.
If the
Restoral on Bell Time-out
option is not selected, the panel will immediately send the
Zone Restoral
Reporting Code when the zone is secured, regardless of whether or not the alarm output is active.
24 Hour type zones will report the restoral immediately once the zone is secured.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone Restoral Reporting Codes .................................................... Section [324]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Restoral on Bell Time-out ............................................. Section [380], Option [2]
Closings (Arming Codes)
The panel will transmit a
Closing
Reporting Code to indicate that the system is armed. A different Reporting
Code can be transmitted for each User Code and Master Code to identify who has armed the system.
A
Special Closing
Reporting Code will be transmitted if the system is armed using any of the following
methods:
• Quick Arming
• Arming via wireless key
If programmed, a
Partial Closing
Reporting Code will be sent along with the closing reporting code if one or
more zones were manually bypassed when the system was armed to warn the monitoring station of a security
compromise.
If the
Closing Confirmation
option is enabled, the control unit will sound a series of eight beeps to confirm to
the user that the closing code was sent and received by the central station.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Closing (Arming) Reporting Codes ...................................... Section [339]-[342]
Special Closing Reporting Code .................................................... Section [343]
Partial Closing Reporting Code ..................................................... Section [343]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Closing Confirmation .................................................... Section [381], Option [4]
Openings (Disarming Codes)
The panel will transmit an
Opening
Reporting Code to indicate that the system has been disarmed. A different
Reporting Code can be transmitted for each User Code and the Master Code to identify who has disarmed the
system.
A
Special Opening
reporting code will be transmitted if the system is disarmed using any of the following
methods:
• Disarming via keyswitch
If an alarm occurred while the system was armed, an
Opening After Alarm
Opening After Alarm
Opening After Alarm
Opening After Alarm
Opening After Alarm
reporting code will be sent along
with an opening reporting code when the user disarms the system.
If Transmission Delay is being used, the Opening After Alarm code must be programmed. See
Section 6.5 “Transmission Delay.”
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Opening (Disarming) Reporting Codes ............................... Section [344]-[348]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Opening After Alarm ....................................................................... Section [328]
Tampers
The panel will report a
Zone Tamper Alarm
Reporting Code if an open condition is present on any zone. A
different Reporting Code can be programmed to identify each zone. The
Zone Tamper Restoral
Reporting
Code will be transmitted immediately when the tamper condition is restored.