background image

encrypted line securitysystemsthe encryption AES128 bit shallbe enabled at the
monitoring station receiver.
• For

UL Commercial Burglary

installations, the

TL2803G(R) E/3G2080 (R)

E/TL280(R)E

islisted as a primary (sole) communication means (heartbeat must

be enabled) or for supplementary (back-up) use in conjunction with a Plain Old
Telephone Service (POTS) line dialer. When the heartbeat transmission over the
Ethernet or cellular network is enabled, using the TL2803G (R) E/3G2080 (R)
E/TL280(R) E with a compatible control unit listed for standard/encrypted line
security, it can provide line securityfor the alarmsystemover the primaryline.
•The TL2803G(R)E/3G2080 (R)E/TL280(R) Eis also suitable to be used with a
compatible controlunit listed for dual line securitytransmission when used in con-
junction with a DACT or a Public Switched Data Network (PSDN) transmitter,
where the PSDN provides the line security and is the primary line. In this mode,
alarm signals are required to be sent simultaneously over both communication
methods.

19

Summary of Contents for PowerSeries Neo 3G2080E

Page 1: ...th Alarm Communicator TL280 R E Internet Alarm Communicator Installation Guide v5 0 Warning This manual contains informationonlimitations regardingproduct useandfunctionandinform ationonthelimitations...

Page 2: ...ime to protectthe occupantsortheirbelongings Motion Detectors Motion detectorscan onlydetectmotion within the designated areasasshown in their respective installation instructions They cannot discrimi...

Page 3: ...850 1900MHz NOTE Only models TL2803GE and 3G2080E are CNC certified for use in Argentina References to model names TL280 R E TL2803G R E and 3G2080 R E throughoutthis manual apply to all specified mod...

Page 4: ...ble control unitlisted for dual line security transmission when used in conjunction with a DACT or a Public Switched Data Network PSDN transmitter where the PSDN provides the line security and is the...

Page 5: ...yption Encryption can only be enabled from the monitoring station receiver Each receiver Ethernet 1 and 2 cellular 1 and 2 can independently have encryption enabled or disabled When encryption is enab...

Page 6: ...e SIM card holder down and slide the holder as indicated by the arrow on SIM holder to LOCK 7 Reconnectthe backup battery and telephone line apply AC power to panel and replace the panel cover Running...

Page 7: ...ushing thick flat washer onto the threaded section of the antenna cable Insert the threaded section through the antenna mounting knockouthole attop rightofpanel d Place the second nylon washer flat fo...

Page 8: ...powerlimited wiring and powerlimited wiring 3 To electrically connectthe communicator to the panel perform the following steps See Figure 3 a Disconnectboth AC power and battery connections from the p...

Page 9: ...0 VA transformer l 12 VDC 7Ah battery 5 Install the RS 232 connections R models only Ifusing the communicator with a 3rd party device wire the connections as per the table below Table 3 RS 232 Connect...

Page 10: ...er to Radio SignalStrength on page 13 Table 4 Signal Strength Display Description Display SIM card active and currentsignal strength SIM card inactive and currentsignal strength Radio notregistered OR...

Page 11: ...2 Communication Delays sub subsection 1 Com munication Delay program 060 seconds 2 In panel section 382 Communicator Option 3 setoption 5 ON NOTE If this option is OFF the yellow status LED on the com...

Page 12: ...t Restore Event is sent by the com municator to the central station receiver The reporting codes are ET0001 for trouble and ER0001 for restore The panel absenteventalways uses the primary receiver acc...

Page 13: ...rk or Cellular connection has been reset Green LED 1 Green LED 2 and Yellow LED Signal Strength NOTE Ifthe yellow LED is flashing signal strength in table below is notvalid See Table 8 for troubleshoo...

Page 14: ...e hub router switch l Check the link lighton the hub router switch is ON Iflink lightis OFF startthe hub router switch l IfDHCP is used ensure thatthe unithas an assigned IP address from the server In...

Page 15: ...nitis still initializing please waitwhile the unitgets its programming and establishes a connection to all programmed receivers NOTE This process may take several minutes to complete Only Green LEDs f...

Page 16: ...r fitness for a particular pur pose And of all other obligations or liabilities on the part of Digital Security Controls Digital Security Controls neither assumes responsibility for nor authorizes any...

Page 17: ...LACEMENT EQUIPMENT FACILITIES OR SERVICES DOWN TIME PURCHASERS TIME THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURYTOPROPERTY DSC recommendsthatthe entire system be completelytested on a re...

Page 18: ...VWLSXODWLRQV SHUWLQHQWHV GH OD LUHFWLYH 5 LHUGXUFK HUNO UW 6 GD GLHVHV HU W GHQ HUIRUGHUOLFKHQ HGLQJXQJHQ XQG 9RUUDXVHW XQJHQ GHU 5LFKWOLQLH HQWVSULFKW 5 6 7 RQ OD SUHVHQWH OD LJLWDO 6HFXULW RQWUROV G...

Page 19: ...or cellular network is enabled using the TL2803G R E 3G2080 R E TL280 R E with a compatible control unit listed for standard encrypted line security itcan provide line securityforthe alarmsystemovert...

Page 20: ...Tyco willaggressively enforce its intellectualproperty rightsto the fullestextent ofthe law including pursuitof criminalprosecution wherevernecessary All trademarksnotowned byTyco are the propertyofth...

Reviews: