Wiring
1. Before wiring the unit, ensure
that all power (AC transformer
and battery) is disconnected
from the control panel.
2. Connect the four Keybus wires
from the control panel (red,
black, yellow and green) to the
keypad terminals. See diagram:
3. If programmed as an input, you can connect a device - such as a
door contact - to the P/Z terminal of the keypad. This eliminates the
need to run wires back to the control panel for the device. To connect
the zone, run one wire from the device to the P/Z terminal and the
other wire from the device to the B (black) terminal. For powered
devices, run the red wire to the R (positive) terminal and the black
wire to the B (negative) terminal. When using end of line supervi-
sion, connect the zone according to one of the configurations out-
lined in your system’s Installation Manual.
4. If the ‘P/Z’ terminal is programmed as an output, the output follows
the PGM programmed in Section [080]. A small relay, buzzer or
other DC operated device may be connected between the positive
supply voltage and the ‘P/Z’ terminal (maximum load is 50mA).
Applying Power
Once all wiring is complete, and the equipment is secured to the build-
ing structure with at least two screws apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the
control panel Installation Manual.
Programming the Keypad
There are several program-
ming options available for
the keypad. These are
described below. Program-
ming the keypad is similar
to programming the rest of
the system. When you are
in the keypad program-
ming sections, the keypad
will display which options
are turned on along the top
of the display. To turn an option on or off, press the number corre-
sponding to the option on the number pad. The numbers of the
options that are currently turned ON will be displayed. For example, if
options 1 and 4 are on, the display will look like this on the different
keypad displays:
For information on programming the rest of your security system,
please refer to your system’s Installation Manual.
Broadcasting LCD Labels
All LCD programming is done per keypad. If more than one LCD key-
pad is present on the system, labels programmed at one keypad can
be broadcast to all other LCD keypads. Perform the following procedure
in order to broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [
][8][Installer
Code][
], then enter section [998] at the keypad that was pro-
grammed. The keypad will now broadcast all the information pro-
grammed to all the other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
NOTE: LCD Label broadcast from this keypad is only compatible with
PC1616/1832/1864 control panels and other PK5500/RFK5500 key-
pads.
Language Programming
(PK5500\RFK5500 Only)
Hold (<>) keys for 2 seconds to enter language programming,
scroll to the desired language and Press [
] to select.
NOTE: If section [077] option 4 is OFF, language programming
can only be performed while in installers programming.
Enrolling the Keypad
The keypad will need to be assigned to a partition and slot if supervi-
sion or keypad zones are being used. Keypad assignments and key-
pad option programming must be done at each keypad individually.
The 1st digit of keypad assignment is used to determine partition
assignment (1 to 8). If partitioning is not used, enter [1]. For Global
Keypads, enter [0].
NOTE: LED and ICON keypads cannot be programmed as Global Keypads.
The 2nd digit of keypad assignment is used to determine slot assign-
ment for keypad supervision. Each keypad will be assigned a different
slot number from 1 to 8. PK5500 and RFK5500 LCD keypads come
defaulted in slot 8. If LCD keypads are used one LCD keypad must
remain in slot 8.
NOTE: The RFK55XX enrolls as two modules:
Light 1 = keypad section of the RFK55XX
Light 17 = receiver section of the RFK55XX
NOTE: Deleting all wireless devices from the RFK55XX or defaulting the
RFK55XX will cause a supervisory fault.
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [
][8][Installer’s Code].
2. Press [000] for Keypad Programming.
3. Press [0] for Partition and Slot Assignment.
4. Enter the 1st digit (0 to 8 for partition assignment).
5. Enter the 2nd digit (1 to 8 for slot assignment supervision).
6. Press the [#] key twice to exit programming.
7. After assigning all keypads, perform a supervisory reset by entering
[
][8][Installer’s Code][902] and wait for 60 seconds.
8. Press the [#] key to exit programming after 60 seconds.
PK55XX/RFK55XX
RED
BLK
YEL
GRN
To zone or
PGM output
4
1
Toggle Option
1 _ _ 4 _ _ _ _