
6HFWLRQ6\VWHP,QWURGXFWLRQ
1.1
Specifications
Downloading Software Support
•
PC1565 v2.1DJRU uses DLS-1 v6.6P and higher.
Flexible Zone Configuration
•
Six fully programmable zones; system expandable to
eight zones using keypad zone inputs and wireless
zones
•
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
•
28 zone types; 8 programmable zone attributes
•
Normally closed, single EOL and double EOL zone wiring
•
Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
•
700mA Supervised Bell Output (current limited at 3
amps), 12Vdc
•
Steady or Pulsed Output
EEPROM Memory
•
Does not lose programming or system status on com-
plete AC and Battery failure
Programmable Outputs
•
One programmable voltage output and one programma-
ble voltage output/input; 20 programmable options
•
PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
•
550 mA Auxiliary Supply, 12 V
DC
•
Positive Temperature Coefficient (PTC) components
replace fuses
•
Supervision for loss of AC power, low battery
Power Requirements
•
Transformer = 16 V
AC
, 40VA (Secondary)
•
Battery = 12V 4Ah minimum rechargeable sealed lead
acid battery (battery not supplied by DSC).
Remote Keypad Specifications
•
Three keypads available:
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z alphanumeric keypad with zone input
- LCD5501Z fixed message LCD keypad with zone input
- LCD5501ZT32-433 keypad / receiver
•
All keypads have five programmable function keys
•
Connect up to eight keypads
•
4-wire (Quad) connection to Keybus
•
Built in piezoelectric buzzer
Digital Communicator Specifications
•
Supports major communication formats including SIA
and Contact ID
•
Event-initiated personal paging
•
Three programmable telephone numbers
•
Two account numbers
•
Supports LINKS2X50 Long Range Radio Transmitter
•
DTMF and pulse dialing
•
DPDT line seizure
•
Anti-jam feature
•
Split reporting of selected transmissions to each tele-
phone number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
•
AC power failure
• AUX Power Supply Trouble
•
Fault by zone
• Loss of internal clock
•
Tamper by zone
• Bell output trouble
•
Fire trouble
• Telephone line trouble
•
Failure to communicate
• Low battery condition (panel)
•
Low battery by device (wireless)
•
Module fault (supervisory or tamper)
False Alarm Prevention Features
•
Audible Exit Delay
• Quick Exit
•
Audible Exit Fault
• Cross Zone Burglary Alarm
•
Communication Delay
• Rotating Keypress Buffer
•
Urgency on Entry Delay
Additional Features
•
Auto Arm at specified time
•
Keypad-activated alarm output and communicator test
•
All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
•
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad.
•
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
•
Uploading and downloading capability
•
Local downloading capability through the use of the
PC-LINK adaptor
•
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to
prevent control panel damage
Summary of Contents for PDigital Security PC1565
Page 4: ...ii PC1565 Wiring Diagram...
Page 55: ...Notes...