28
[28]
Swinger Shutdown and Transmission Delay / Bell Delay
Swinger Shutdown determines how many alarms a zone may initiate and report before additional alarms are no longer
reported.
Note that the Fire Zone cannot be shut down; Fire Zone alarms will always be transmitted.
Program a 2-digit number from “00” to “99”; the default setting is “03”. With the default setting of “03”, a zone may
generate and report three alarms; any alarms after this will not be reported to the monitoring station until the Swinger
Shutdown counter is reset. The Swinger Shutdown counter may be reset at 12:00 am or when the system is armed;
refer to Section [21] Second System Option Code Zone Light 4.
Transmission Delay determines the delay, in seconds, before an event is transmitted. Note that if the system is
disarmed before the Transmission Delay expires, no transmission will be initiated.
Bell Delay determines the delay, in minutes, before the bell is activated. Note that if the system is disarmed before the
Bell Delay expires, no bell output will be initiated. Valid entries for the Bell Delay range from 01 to 99 minutes; the default
setting is 00.
The Transmission and Bell Delays are only applied to burglary zones; 24-hour and Fire Zones will not be
delayed.
[29]
Communications Format
This Section sets the type of format in which Communication Buffers 1 and 2 will communicate. For each
communication buffer, enter two digits from the list below. The selection for each buffer is determined by the type of
receiver being called. Enter the format number for the first communication buffer first. It is necessary to program both
format numbers even if the first communication buffer is the only one being used.
Handshake
Formats
[00] SILENT KNIGHT / ADEMCO SLOW 10 BPS
1400 Hz
3/1, 3/2, 4/1 and 4/2 non-extended
[01] SESCOA, FRANKLIN, DCI, VERTEX 20 BPS
2300 Hz
3/1, 3/2, 4/1 and 4/2 non-extended
[02] SILENT KNIGHT FAST 20 BPS
1400 Hz handshake 3/1, 3/2, 4/1 and 4/2 non- extended
[03] RADIONICS
2300/1400 Hz*
3/1, 4/2 non-extended
[04] RADIONICS
2300/1400 Hz*
3/1, 4/2 non-extended with parity
[05] SESCOA super speed
[06] SILENT KNIGHT, ADEMCO SLOW 10 BPS
1400 Hz
3/1 extended
[07] SESCOA, FRANKLIN, DCI, VERTEX 20 BPS
2300 Hz
3/1 extended
[08] SILENT KNIGHT FAST 20 BPS
1400 Hz
3/1 extended
[09] RADIONICS
2300 / 1400 Hz*
3/1 extended
[10] RADIONICS
2300 / 1400 Hz*
3/1 extended with parity
[11] Sescoa super speed (with identified openings/closings)
[12] DTMF Fast, Slot Programming Method
[13] Sur-Gard 4/3 DTMF with Parity
2300Hz
This format will respond to 2300Hz handshakes only.
[14] Semadigit DTMF Pager Format
[15] Semaphone Pager
[16] Private Line
* See Section [20] for Radionics handshake option.