17
[10] Third System Option Code
Zone Light 1: 2-minute Keypad Time-out Enabled / Disabled
ON:
2-minute Keypad Time-out Enabled. If no keys are pressed for 2 minutes, all keypad lights will be shut
OFF.
NOTE:
The 2-minute Keypad Timeout must
not
be selected if the LCD600 Keypad or the Escort
Voice Assisted Security Control Module is used with the PC2525.
• OFF:
No Keypad Time-out. The keypad lights will remain ON at all times.
Zone Light 2: [F] Key Enabled / Disabled
ON:
[F] Key Disabled. The [F] Key will not sound an alarm when pressed.
• OFF:
[F] Key Enabled. Pressing and holding the [F] Key for 2 seconds will generate a Fire alarm; the bell or
siren will sound with a pulsing tone, and an alarm reporting code (if programmed) will be transmitted.
Zone Light 3: [P] Key Keypad Sounder Options
• ON:
[P] Key: Keypad Buzzer Silent. When a [P] Key alarm is generated, the keypad sounder will not beep to
acknowledge the alarm.
OFF:
[P] Key: Keypad Buzzer Aduible. When a [P] Key alarm is generated, the keypad sounder will beep 3
times to acknowledge the alarm.
Zone Light 4: [P] Key Bell Options
ON:
[P] Key Audible Alarm. The BELL output will be activated when the [P] Key is pressed and held for 2
seconds.
• OFF:
[P] Key Silent Alarm. The BELL output will not be activated when a [P] Key Alarm is generated.
Zone Light 5: Bell Shutdown Enabled / Disabled
ON:
Bell Shutdown Enabled. The BELL output will not be activated for zones that have exceeded the limit of
alarms set in the Swinger Shutdown counter.
• OFF:
Bell Shutdown Disabled. The BELL output will be activated for all alarms on all zones, even after the
Swinger Shutdown counter has been exceeded. The BELL output will continue to be activated for all
alarms, even though the alarms will not be reported once the Swinger Shutdown counter has been
exceeded.
Zone Light 6: Bell Squawk Options
ON:
Bell Squawk Enabled. The bell or siren will sound a single squawk when the system is being armed, and
a double squawk when the system is being disarmed.
• OFF:
Bell Squawk Disabled. The bell or siren will not squawk when the system is armed or disarmed.
Zone Light 7: Bell During Auto-Arm Options
• ON:
No Bell During Auto-Arm. The bell or siren will not be activated during the 1-minute Auto-Arm warning
time.
OFF:
Bell During Auto-Arm. The bell or siren will sound a single squawk every 10 seconds during the 1-minute
Auto-Arm warning time.
Zone Light 8: Exit Delay Termination Enabled / Disabled
ON:
Exit Delay Termination Enabled. The Exit Delay will be terminated once the Delay Zone for the entry/exit
door or area is restored. All audible options associated with the Exit Delay will be silenced when the Exit
Delay is terminated.
• OFF:
Exit Delay Termination Disabled. The Exit Delay timer will continue to count even after the Delay Zone for
the entry/exit door or area is restored. All audible options associated with the Exit Delay will function until
the time programmed for the Exit Delay has elapsed.
•
Factory default setting