DSC maxsys PC4020KT System Manual Download Page 22

18

To arm the partition which you are at simply press [

] or

use the hotkey (0). The message

EXIT DELAY
IN PROGRESS

will appear on the keypad with the exit delay timer if it is
enabled. Instead of arming their own partition, if the user
decides to select another partition to arm the message

SELECT (0)

< >

ARM PARTITION

R

Use the arrow keys to scroll to the “For Options” menu.
Selecting (0) “To Arm” will arm the selected partition and
display the message

EXIT DELAY
IN PROGRESS

for 2 seconds and then return the user to the arming
menu of their own partition.

If (1) “For Options” is selected the user will be prompted
with the message

KEYPAD LOANED TO
(Partition Label)

From here the user is capable of performing all [

]

functions (e.g. [

] [7] Door Strike) and arm the panel

using conventional methods.

Once the [#] key is pressed or 20 seconds of idle time
(no key presses made or not active in a submenu) the
keypad will return to its normal state displaying the
message

RETURNING TO
(Partition Label)

Disarming

Enter the premises through the designated exit-entry
door. The keypad buzzer will be on. Go to the keypad
and enter the 4 digit or 6 digit access code. If an error is
made in entering the code, press the [#] key and enter
the code again. The “Armed” light will go out and the
keypad buzzer will stop. The correct access code must
be entered before the allowed entry time expires. To
change the entry time see “Installers Programming
Command”, [

][8]. If an alarm occurred while the panel

was armed, the “View Memory” message will be on the
display with the zone name for the zone that caused the
alarm. The display will keep those messages on for two
minutes or until the [#] key is pressed to return the panel
to the normal arm-disarm mode.

To disarm by using a multi partition access code the
keypad will display the message

(0) TO ARM

< >

(Partition Label)

R

The lower right hand corner of the display will show the
partition status using the letter “R” for Ready, and “N” for
Not ready.

Use the [<] [>] keys to scroll though the assigned
partitions. Only partitions to which the access code is

assigned will be displayed. The message

(2) TO SELECT

< >

(Partition Label)

A

will be displayed with the partition status at the right corner
of the LCD.

To disarm the partition being viewed simply press [

] or

use the hot  key (0). If (1)“For Options” is selected the user
will be prompted with the message

KEYPAD LOANED TO
(Partition Label)

on the LCD display. From here the user is capable of
performing all 

 functions (e.g. [

] [7] Door Strike) and arm

the panel using the conventional methods.

Once the [#] key is pressed or 20 seconds of idling time (no
key presses made or not active in a submenu) the keypad
will return to its normal state displaying the message

RETURNING TO
(Partition Label)

Auto-bypass/Home-Away Arming

If a correct access code is entered and you do not exit the
premises, the system will, at the end of the Exit delay time,
arm with interior zones automatically bypassed if those
interior zones have been programmed as “Home-Away”
zones. These zones will remain bypassed until [

][1] is

entered to reactivate bypassed home-away zones.

This is a convenience feature for the user who wishes to
remain on the premises with the system armed. The user
does not have to manually bypass the Home-Away zones.

To reactivate the Home-away zones that have been
automatically bypassed, press [

][1]. This command is a

quick method of fully arming the system in residential
applications before going to bed.

Note: The auto-bypassed zones will only send a tamper
alarm when the tamper condition is activated, using
Double EOL resistors.

Zone Bypassing

[

]+[1]

A bypassed zone will not cause an alarm. If a zone is
bypassed the panel may be armed even if the zone is open.
Use zone bypassing when access is needed to part of the
protected area. Also, damaged wiring or contacts on a
zone may be temporarily bypassed until repairs can be
made so that the panel can be armed.

To bypass zones, enter [

] [1]. An access code may be

required if the installer has enabled that option. A menu will
appear.

[0] Bypass Open Zones 

[0] Bypass Open Zones 

[0] Bypass Open Zones 

[0] Bypass Open Zones 

[0] Bypass Open Zones allows the user to bypass only the
open zones that are on that partition. Use the [<][>] keys to
scroll through the open zones. Next to the zone label will
the a [!] this character is used to indicate that the zone is
open. To select the open zone to be bypassed press the
[

] key. A [

] will appear next to the zone label to indicate

that the zone has been bypassed.

Summary of Contents for maxsys PC4020KT

Page 1: ...k 1 System Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read ...

Page 2: ...properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors walls ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected A ...

Page 3: ...Panel 6 Programming the System 6 Hardware Reset of Memory to Factory Defaults 7 PC4020 Main Board Specifications_______________________________________ 8 Control Panel 8 Output Voltage 8 Remote Keypad 8 Module Specifications ____________________________________________________ 9 PC4108 Expansion Module 9 PC4116 Expansion Module 9 PC4164 Expansion Module 9 PC4204 High Current Output Module 9 PC4216...

Page 4: ...25 Walk Test 6 Walk Test Code 25 Utility Output 7 or 7 Access Code 25 Installer s Programming Commands 8 Installer s Code 25 At Home Arming 9 Access Code 25 Quick Arm 0 25 Quick Exit 0 When Armed 25 Keypad Zones 25 Access Control Functions _______________________________________________ 26 Reader LED Flash Rates 26 Buzzer Operation 26 How to Setup and Use an Access Card 26 Arming and Disarming Usi...

Page 5: ...in panel processes signal information and communicating with the monitoring station The main panel is capable of supervising 16 zones any of which may be defined for fire or burglary applications and also manages up to eight separate and fully independent partitions assigning zones and their controlling keypads in accordance with installer programming The basic 16 zone capability of the PC4020 can...

Page 6: ...s PC4003C 1 module PC4004C Attack resistant for PC4020 plus 2 modules PC3000 PC4820 Supervised Alarm Output Bell Output 700 mA fused at 5 Amps 12 VDC commercial and 11 6 12 6 VDC residential Steady or Pulsed Output Programmable for 1 of 28 options Event Buffer 3000 events Date and time stamp Event Buffer Viewing any System Master is able to view 2500 events through the keypad including date and ti...

Page 7: ...ill allow the partition setup done without mistakes Locate any zone expansion modules PC4108 or PC4116 required close to groups of zones for easier wiring Decide on the order to enroll the expansion modules The first 16 zones 1 through 16 are on the main panel As each module is enrolled it will be assigned in sequence the next available group of zones If an 8 zone module PC4108 was enrolled first ...

Page 8: ...ote the zone may require to be tripped more depending on the location of the zone On the restoral of the zone for the second time the panel will display a rating of the zones placing with respect to RF strength The Placement Result may be Good Fair or Poor A placement rating of Good means that the zone is placed in a location that has strong RF transmission strength A placement rating of Fair mean...

Page 9: ...ized For example if the microprocessor on the module has been scrambled due to a transient the PC4020 will power down the COMBUS the PC4204 will mimic the PC4020 and cut off its power supply to the module The module will be powered down When the PC4020 returns power to the COMBUS the PC4204 will reconnect its power supply and the power to the module will return Because the module was powered down ...

Page 10: ...dily available Once all modules are enrolled perform a diagnostics check on the panel to determine if any problems are present see Diagnostics Programming the System The PC4020 has the capability to operate as 8 separate alarm systems called Partitions Dividing the panel into Partitions will allow you to control access to specific areas When the PC4020 is first powered up all zones on the main boa...

Page 11: ... light on the keypad If it is on press then 2 to determine the trouble The Trouble Display section in Keypad Functions gives a description of the different trouble conditions Step 5 Instructing the End User Describe system operation to authorized users Provide user with the instruction manual and instruct them to read it to become familiar with the system operation Instruct the user to test the sy...

Page 12: ...Internal clock locked to AC power frequency or optional crystal time base Switched Auxiliary Supply Output Programmable for 1 of 35 options 11 6 12 6 VDC 300 mA maximum Battery 12 volt 4 Ah minimum rechargeable gel cell or sealed lead acid battery Transformer 16 5 VAC 40VA Output Voltage Typically with normal AC on and a fully charged battery the output voltage will be 13 8 VDC With AC off and the...

Page 13: ...es Low COMBUS supervision to the PC4020KT AUX output provides 125mA supply power at 13 8V Provides Lock output supervision to the PC4020 Provides Reader power supervision to the PC4020 PC4108 Expansion Module Up to 128 zones total on system 8 zone expansion module Normally closed loops EOL resistor Double EOL resistor support 4 wire QUAD hook up to COMBUS Nominal current draw of 25 mA Provides Tam...

Page 14: ... OF LINE RESISTOR ANY Z TERMINAL ANY COM TERMINAL TYPICAL ZONE CIRCUITS TELEPHONE CONNECTION GROUND CONNECTION 120 V 40 VA TRANSFORMER 16 18 V 40 VA DO NOT CONNECT TO RECEPTACLE Nut Washer Cabinet Bolt Ground Rod TO GROUND CONNECTION INCOMING LINE FROM TELEPHONE COMPANY OUT TO TELEPHONE EQUIPMENT ON PREMISES GRY BRN RED GRN Recommended use with Double EOL Resistors 5600Ω End Of Line resistor colou...

Page 15: ...11 Module Hookup Diagram ...

Page 16: ...WIRING IS REQUIRED FOR RESIDENTIAL FIRE ALARM SYSTEMS SW AUX PROGRAMMED FOR SENSOR RESET TO ANY COM TERMINAL TO ANY ZONE Z TERMINAL TO ZONE Z TERMINAL PROGRAMMED FOR FIRE TO ANY COM TERMINAL BELL LOOP 700 mA MAX 4 WIRE SMOKE DETECTOR POWER 11 VDC 400 mA MAX Bell Current mA 50 2750 838 1375 419 690 210 460 140 345 105 275 83 230 70 195 59 1740 530 870 265 435 132 290 88 215 65 170 52 140 43 125 38 ...

Page 17: ...e with controlled devices TERMINAL CONNECTIONS COMBUS Terminals RED BLK YEL and GRN Connect the red wire of the COMBUS to the RED terminal the black wire to the BLK terminal the yellow wire to the YEL terminal and the green wire to the GRN terminal The COMBUS is wired in the same manner on all modules The COMBUS is used by the main panel to communicate with and supply power to the modules The COMB...

Page 18: ...s and jacks meet the dimension tolerance and metallic plating requirements of 47 C F R Part 68 Subpart F TIP Green wire Incoming line from RNG Red wire telephone company T 1 Brown wire Outgoing line to R 1 Grey wire house telephone s Battery Connections Do not connect the battery or the transformer until the wiring is complete Connect the red battery lead to the positive battery terminal and the b...

Page 19: ... An access code is a 4 or 6 digit optional number which will permit access to the system i e Arm Disarm control Installer s Programming etc User access codes are programmed in the User Programming section 5 The default access code is 1234 for 4 digit option and 123456 for 6 digit option See User Programming Commands for details on programming access codes Global Keypads What is a Global Keypad A g...

Page 20: ...on Label Pressing the right arrow key displays the message SELECT 1 FOR OPTIONS If the selected partition is armed the LCD will prompt with the message SELECT 0 DISARM PARTITION If option 0 is selected the panel will disarm the partition and display the message SYSTEM DISARMED NO ALARM MEMORY for 2 seconds Then the display will return to SELECT 1 Partition Label If the user chooses 1 For Option th...

Page 21: ...r communicator program information The installer s program code may be changed by the installer Arming Close all protected doors and windows and stop movement in areas covered by motion detectors The Enter Code To Arm System message should be on the LCD display The system cannot be armed unless the Enter Code to Arm System or Secure System or Enter Code message is displayed If Double EOL resistors...

Page 22: ... displayed with the partition status at the right corner of the LCD To disarm the partition being viewed simply press or use the hot key 0 If 1 For Options is selected the user will be prompted with the message KEYPAD LOANED TO Partition Label on the LCD display From here the user is capable of performing all functions e g 7 Door Strike and arm the panel using the conventional methods Once the key...

Page 23: ...ns If one of these conditions occurs the keypad TROUBLE indicator will light and the audible indication will sound two short beeps every 10 seconds When the key is pressed the audible indication will stop but the trouble indicator light will remain ON until the trouble is cleared Trouble conditions can also be transmitted to the monitoring station Press the then 2 keys to display the types of trou...

Page 24: ...unicating COMBUS Low Pwr Modules are not getting enough voltage from the COMBUS Check for proper connection of COMBUS or the COMBUS needs to be repowered See 4204 modules and the 4204 PGM COMBUS power option for supplying voltage to the COMBUS See Diagnostics in the Programming Manual to determine which module has low voltage Internal Fault A problem has occurred with the COMBUS microprocessors If...

Page 25: ...low battery condition To view which zone has the trouble press the key while viewing the trouble condition The zone s with the trouble condition will be displayed in numerical order on the display A keypad trouble is generated when the system is disarmed and a visual Zn Low Batt Fault trouble and trouble reporting code will be transmitted Automation Fault This trouble condition will occur well the...

Page 26: ...hedule window is active unless a user with a Privileged card grants the user access to the system When the Second Card Schedule is not active out of window the user will be able to access the assigned door s on the system Programming Additional Access Codes Using a System Master or a Supervisory Code Press then 5 to enter the User Programming Commands the keypad will display the message Enter Your...

Page 27: ...ode will not operate on any partition 7 To Exit the menu press the key 2 User Name Search 1 This option will allow selection of the user to be programmed by searching using the user name To do this enter the first letter of the user s name eg for John enter the letter J press the 4 key once and press either arrow key or This will find all users whose names begin with the selected letter upper or l...

Page 28: ...eypad When this function is selected the Keypad Setup menu will appear on the keypad Bright Control adjusts the level of backlighting on the LCD display and the backlighting on the keys Contrast Control adjusts the contrast of the lettering on the LCD display Use the keys to toggle through the eight different settings and press to select the level of preference Note To adjust the keypad brightness...

Page 29: ...nd P keys will activate for all active partitions any valid access code from any partition may silence the alarm Note See KEYPAD TOG OPT in the Programming Guide for changing keypad zones options The sixth message is Zone Tamper It will be displayed if the zone is opened while using Double EOL resistors See Event Messages in the Programming Guide Note The Zone Fault and Zone Tamper event messages ...

Page 30: ...r each door to allow access at only specific times of the day If the user is to have arming disarming abilities the user must be assigned to a partition and the installer must assign the door s arm disarm mask to the same partition s To gain access to a locked access control door first swipe the card in the method indicated by the access card reader installation manual When the LED on the reader c...

Page 31: ... the access code names See ZONE LABEL in the Programming Manual for programming zone labels The printout will then be as Sample 3 The PC4400 sends events to the printer as they occur If the printer is off line or disconnected the PC4020 keeps new events in memory until they are ready to be printed When the printer is brought back on line the PC4400 will send the new events to the printer If 450 ne...

Page 32: ... to the tip and ring terminals on the panel A DTS 1 must be connected to the lines and in the local mode Program the downloading access code and panel I D code Program a zone for Forced Answer See Zone Type in the Programming Guide This zone is only meant to be temporary to initiate downloading It can later be changed back to the required zone type Make sure the access code and panel I D code are ...

Page 33: ...99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 2...

Page 34: ...er 51 1 52 2 53 3 54 4 55 5 56 6 57 7 58 8 59 9 60 10 61 11 62 12 63 13 64 14 65 15 66 16 Indicated PC4700 Number Fire Module 67 1 Indicated VPM 2 Number Voice Prompting Module 68 1 Indicated PC4820 Number Access Control 69 1 70 2 71 3 72 4 73 5 74 6 75 7 76 8 77 9 78 10 79 11 80 12 81 13 82 14 83 15 84 16 E Communication error T Tamper open LV Low voltage to module Indicated For Future Use Number...

Page 35: ......

Page 36: ... 1997 2002 Digital Security Controls Ltd Toronto Canada www dsc com Technical Support 1 800 387 3630 Printed in Canada 29002586 R0 ...

Reviews: