11.

TOXICOLOGICAL  INFORMATION

ACUTE  TOXICITY:

Peroral:    Rat;  female;  LD50  =  20300  mg/kg

Percutaneous:    Based  on  information  for  a  similar  material:

           Rabbit; LD50 = > 10000 mg/kg

DEVELOPMENT  TOXICITY:    Contains  component(s)  which  did  not  cause  birth  defects  or  any  fetal  effects  in  lab  animals.,    The

component(s)  is/are:,  Propylene  glycol.

REPRODUCTIVE  TOXICITY:    Contains  component(s)  which  did  not  interfere  with  reproduction  in  animal  studies.,  Contains

component(s)  which  did  not  interfere  with  fertility  in  animal  studies.,  The  component(s)  is/are:,  Propylene  glycol.

CHRONIC  TOXICITY  AND  CARCINOGENICITY:    Similar  formulations  did  not  cause  cancer  in  laboratory  animals.

GENETIC  TOXICOLOGY:

In  Vitro:    In  Vitro  mutagenicity  studies  were  negative.

In  Vivo:    Mutagenicity  studies  in  animals  were  negative  for  component(s)  tested

SIGNIFICANT  DATA  WITH  POSSIBLE  RELEVANCE  TO  HUMANS:    In  rare  cases,  repeated  excessive  exposure  to  propylene  glycol

may  cause  central  nervous  system  effects.

12. ECOLOGICAL  INFORMATION

ENVIRONMENTAL  FATE:    Based  largely  or  completely  on  information  for:    Propylene  glycol.    Material  is  readily  biodegradable.

Passes  OECD  test(s)  for  ready  biodegradability.    Degradation  is  expected  in  the  atmospheric  environment  within  minutes  to  hours.

ECOTOXICITY:    Based  largely  or  completely  on  information  for:    Propylene  glycol.    Material  is  practically  non-toxic  to  aquatic

organisms  on  an  acute  basis  (LC50/EC50  .  100mg/L  in  most  sensitive  species  tested).

FURTHER  INFORMATION:    Based  largely  or  completely  on  information  for:    Propylene  glycol.    Bioconcentration  potential  is  low

(BCF  <  100  or  Log  Pow  <  3).    Potential  for  mobility  in  soil  is  very  high  (Koc  between  0  and  50).

13. DISPOSAL  CONSIDERATION 

(See  Section  15  for  Regulatory  Information)

DISPOSAL:    DO  NOT  DUMP  INTO  ANY  SEWERS,  ON  THE  GROUND  OR  INTO  ANY  BODY  OF  WATER.   All  disposal  practices

must  be  in  compliance  with  all  Federal,  State/Provincial  and  local  laws  and  regulations.    Regulations  may  vary  in  different  locations.
Waste  characterizations  and  compliance  with  applicable  laws  are  the  responsibility  solely  of  the  waste  generator.    THE  DOW
CHEMICAL  COMPANY  HAS  NO  CONTROL  OVER  THE  MANAGEMENT  PRACTICES  OR  MANUFACTURING  PROCESS  OF
PARTIES  HANDLING  OR  USING  THIS  MATERIAL.    THE  INFORMATION  PRESENTED  HERE  PERTAINS  ONLY  TO  THE
PRODUCT  AS  SHIPPED  IN  ITS  INTENDED  CONDITION  AS  DESCRIBED  IN  MSDS  SECTION  2  (Composition/Information  on
Ingredients).    FOR  UNUSED  &  UNCONTAMINATED  PRODUCT,  the  preferred  options  include  sending  to  a  licensed,  permitted:
recycler,  reclaimer,  incinerator  or  other  thermal  destructive  device.    As  a  service  to  its  customers,  Dow  can  provide  names  of
information  resources  to  help  identify  waste  management  companies  and  other  facilities  which  recycle,  reprocess  or  manage
chemicals  or  plastics,  and  that  manage  used  drums.    Telephone  Dow’s  Customer  Information  Centre  at  1-800-258-2436  or  0-989-
832-1556  (U.S.),  or  1-800-331-6451  (Canada)  for  further  details.

14. TRANSPORT  INFORMATION

NON-BULK  Proper  Shipping  Name:

NOT  REGULATED

BULK  Proper  Shipping  Name:

NOT  REGULATED

The  information  is  not  intended  to  convey  all  specific  regulatory  or  operational  requirements/information  relating  to  this  product.
Additional  transportation  system  information  can  be  obtained  through  an  authorized  sales  or  customer  service  representative.    It  is  the
responsibility  of  the  transportation  organization  to  follow  all  applicable  laws,  regulations  and  rules  relating  to  the  transportation  of  the
material.

  15. REGULATORY  INFORMATION 

(Not  meant  to  be  all-inclusive—selected  regulations  represented)

FEDERAL/NATIONAL

OSHS  Hazard  Communication  Standard
This  product  is  not  a  “Hazardous  Chemical”  as  defined  by  the  OSHA  Hazard  Communication  Standard,  29  CFR  1910.1200.

Superfund Amendments  and  Reauthorization Act  of  1986  Title  III  (Emergency  Planning  and  Community  Right  To  Know Act)  Section  313
To  the  best  of  our  knowledge  this  product  does  not  contain  chemicals  at  levels  which  require  reporting  under  this  statute.

Superfund Amendments  and  Reauthorization Act  of  1986  Title  III  (Emergency  Planning  and  Community  Right  To  Know Act)  Section  302
To  the  best  of  our  knowledge  this  product  does  not  contain  chemicals  at  levels  which  require  reporting  under  this  statute.

Superfund Amendments  and  Reauthorization Act  of  1986  Title  III  (Emergency  Planning  and  Community  Right To  Know Act)  Section  311  &  312

Delayed  (Chronic)  Health  Hazard:

NO

Fire  Hazard:

NO

Immediate  (Acute)  Health  Hazard:

NO

Reactive  Hazard:

NO

Sudden  Release  of  pressure  Hazard:

NO

Toxic  Substance  Control  Act  (TSCA)

All  components  of  this  product  are  on  the  TSCA  Inventory  or  are  exempt  from  TSCA  Inventory  requirements.

CEPA  -  Domestic  Substances  List  (DSL)

All  substances  contained  in  this  product  are  listed  on  the  Canadian  Domestic  Substances  List  (DSL)  or  are  not  required  to  be  listed.

European  Inventory  of  Existing  Commercial  Chemical  Substances  (EINECS)

The  components  of  this  product  are  on  the  EINECS  inventory  or  are  exempt  from  EINECS  inventory  requirements.

Summary of Contents for 2250

Page 1: ...Operators Manual Hose Reel 2250 S N 1548 01 DRYAIR Manufacturing Corp 400 Service Road PO Box 126 St Brieux SK Canada S0K 3V0 Tel 306 275 4848 1 888 750 1700 Fax 306 275 4664 ...

Page 2: ... Module 2 1 Heat Transfer Fluid 2 1 Material Safety Data Sheet 2 2 Material Safety Data Sheet 2 5 Introduction 3 1 Operating Features 3 1 Drive Features Power Requirements 3 1 Reel Capacities 3 1 Transportation Storage 3 1 Setup Operation 4 1 Manual Controls 4 1 Mechanical Drive Components 4 2 Maintenance 5 1 Electric Motor 5 2 GearBox 5 2 Torque limiter adjustment 5 3 ...

Page 3: ...nce and or replacement equipment rental cost Maintenance repair or service items not related to warrantable defects Loss or damage during shipping Failure resulting from lack of or improper maintenance Damage caused by operator abuse negligence or improper operation Damage resulting from improper voltage supply Damage from improper installation Installation done by other than the manufacturer Non ...

Page 4: ...ith warranty claim number When claiming for warranty labour the allowable warranty labour rate will be 45 00 hour The factory reserves the right to adjust the number of hours claimed where deemed necessary The factory may at times specify allowable labour for certain warranty procedures Mileage and travel time to and from the customer are not eligible for warranty credit Freight charges for warran...

Page 5: ...en working with heat transfer fluid DOWFROST HTF BOSS CHILL PG Fluid handling precautions Ventilation Good general ventilation should be sufficient for most conditions Respiratory protection No respiratory protection should be needed Skin protection For brief contact no precautions other than clean body covering clothing should be needed Use impervious gloves when prolonged or frequently repeated ...

Page 6: ... adverse effects on the mother should have no effect on the fetus REPRODUCTIVE EFFECTS In animal studies has been shown not to interfere with reproduction 4 FIRST AID EYE Flush eyes with plenty of water SKIN Wash off in flowing water or shower INGESTION No adverse effects anticipated by this route of exposure incidental to proper industrial handling INHALATION Remove to fresh air if effects occur ...

Page 7: ...vailable oxygen is limited as in a fire or heated to very high temperatures by hot wire or plate carbon monoxide and other hazardous compounds such as aldehydes might be generated HAZARDOUS POLYMERIZATION Will not occur 11 TOXICOLOGICAL INFORMATION See Section 3 for Potential Health Effects For detailed toxicological data write or call the address or non emergency number shown in section 1 SKIN th...

Page 8: ... and may differ from one location to another it is the buyer s responsibility to ensure that its activities comply with federal state or provincial and local laws The following specified information is made for the purpose of complying with numerous federal state or provincial and local laws and regulations See other sections for health and safety information U S REGULATION SARA 313 INFORMATION To...

Page 9: ...HYSICIAN No specific antidote Treatment of exposure should be directed at the control of symptoms and the condition of the patient 5 FIRE FIGHTING MEASURES FLAMMABLE PROPERTIES Refer to section 9 PHYSICAL AND CHEMICAL PROPERTIES EXTINGUISHING MEDIA Water fog or fine spray Dry chemical fire extinguishers Carbon dioxide fire extinguishers Foam Do not use direct water stream May spread fire Alcohol r...

Page 10: ...d PERSONAL PROTECTION RESPIRATORY PROTECTION Atmospheric levels should be maintained below the exposure guideline PROTECTION When respiratory protection is required for certain operations use an approved air purifying respirator In dusty or misty atmospheres use an approved particulate respirator EYE PROTECTION Use safety glasses OTHER PROTECTIVE EQUIPMENT No precautions other than body covering c...

Page 11: ...edients FOR UNUSED UNCONTAMINATED PRODUCT the preferred options include sending to a licensed permitted recycler reclaimer incinerator or other thermal destructive device As a service to its customers Dow can provide names of information resources to help identify waste management companies and other facilities which recycle reprocess or manage chemicals or plastics and that manage used drums Tele...

Page 12: ...uals are not trained in the use of this hazard rating system You should be familiar with the hazard communication programs applicable to your workplace RECOMMENDED USES AND RESTRICTIONS Intended as a heat transfer fluid for closed loop systems Dow recommends that you use this product in a manner consistent with the listed use If your intended use is not consistent with Dow s Stated use please cont...

Page 13: ...d The reel motor is a single phase 3 4 horse electric motor which produces a reel speed of 18 RPM Drive and motor protection against inertial forces is provided by an adjustable torque limiter clutch located between the motor gear box and the reel spool The torque limiter clutch provides quick braking action and a smooth interface with the spool s high inertial forces Reel Capacities The HR2250 Ho...

Page 14: ...y connecting the foot switch you can load or unload hose by depressing the foot switch 1 2 which is momentary will only operate when depressed Reel Direction Modes Mode 1 UNLOAD Mode 2 LOAD Caution Take care not to allow your hands feet or clothing to become trapped by any of the reel smovingmechanisms Mode 1 UNLOAD The UNLOAD mode is acheived with the mode toggle switch 1 2 in the UNLOAD position...

Page 15: ...er 102 1 gear reduction 5 8 input shaft size 1 output shaft CAUTION Do not operate the unit without ensuring it contains the correct amount of oil Do not overfill or underfill with oil Injury to personnel unit or other equipment may result Oil should be changed with greater frequency if unit is used in severe environment dusty or high humidity WARNING Oil housing and other components can reach hig...

Page 16: ...utch is factory set at Dryair periodic adjustment may be required It is recommended the torque setting of the clutch be checked twice per season see Maintenance section With prolonged use the two friction disks located on either side of the A plate sprocket will eventually show wear It is important that the torque limiter clutch is adjusted properly If the clutch slips too easily the spool will ta...

Page 17: ...disconnect in the open position Disconnect all power including external control power that may be present servicing the drive controller WAIT 15 MINUTES for the DC bus capacitors to discharge Then follow the DC bus voltage measurement procedure beginning on page 5 of the ALTIVAR 11 Adjustable Speed Drive Controllers Start up Guide to verify that the DC voltage is less than 45 Vdc The drive control...

Page 18: ...t the following oil be used Spartan EP 320 industrial gear oil any other gear oil will void warranty Oil Filling Procedure Remove Fill 1 and Breather Plug 2 Clean threads on the removed plugs and the plug holes with degreaser Fill gear box with the recommended lubricant see above to a level near the center line of the uppermost horizontal shaft or until lubricant comes out of the oil level plug ho...

Page 19: ... with your legs and not your back You should be able to cause the clutch to just slip with full lifting force If the clutch does not slip or slips too easily refer to the torque adjust procedure below Torque adjust procedure Insure that the adjusting nut is in a finger tight position If the adjustment nut is tighter than finger tight loosen and complete previous step Match mark the adjusting nut w...

Reviews: