Dry Air TECHNO PRO 5000 Owner'S Manual Download Page 2

 

 

 

IMMEDIATELY 

Check for any External or Internal Damage From Shipping 

 

Please inspect your unit within 7 DAYS from date 

received.  If concealed damage is noted, contact the 

delivering carrier immediately for inspection. 

 

This unit was delivered to the carrier in first class 

condition.  Shipper assumes no further liability after 

delivery to the transportation company.  Your claim 

should be filed against the carrier for damage  

of any nature. 

 

PACKAGING 

Be sure to keep all original packaging.  Original 

packaging will help protect unit from freight damage if 

there is a need to return. 

 
 
 

Dry Air Technology 

Toll Free U.S. & Canada:  888.755.9176 

Overseas:  (001) 360.755.9176 

 

 

 

 

 

Email: [email protected] 

Summary of Contents for TECHNO PRO 5000

Page 1: ...ase read before using the dehumidifier and save for future reference Purchase Date ______________________________Serial No __________________________________ 313 North Oak Street Burlington Washington...

Page 2: ...o the carrier in first class condition Shipper assumes no further liability after delivery to the transportation company Your claim should be filed against the carrier for damage of any nature PACKAGI...

Page 3: ...s outer cover removed Personal injury may result Drapes or other loose fabrics can be drawn against the unit restricting its airflow This condition may cause the unit to overheat Assure that there is...

Page 4: ...This can diminish water extraction and create undue pressure on the refrigeration system The coils should be cleaned about every 8 to 12 weeks If the Techno Pro 5000 Dehumidifier is used in a dusty en...

Page 5: ...osting The evaporator coils on the Techno Pro 5000 feature an epoxy phenolic coating most often used in heavily corrosive and grueling marine environments This coating prevents corrosion and aluminum...

Page 6: ...RD 00C P4N20147 Wire Grill RD 00C M5A10150 Grill w Cord Wrap RD 00C M5A10204 Rubber Foot AF 00C R4A10044 Air Filter RD 00C NNAN0149 Strain Relief AF 00E PNN10015 20 Power Cord CF 00E N4A10004 Switch...

Page 7: ...ing the fan With the fan off and the HG solenoid energized hot gas from the compressor will be circulated through the evaporator coil causing a temperature rise to defrost the coil The defrost cycle w...

Page 8: ...313 North Oak Street Burlington WA 98322 USA Phone 360 755 9176 Fax 360 755 9236 Toll Free from U S or Canada 1 888 755 9176 Email info dryairtech com www dryairtech com...

Page 9: ...printed control board or Ranco mechanical control Hm hour meter PM humidity control power module Sw1 on off switch Ps condensate purge switch float switch internal to pump 313 North Oak Street Burlin...

Page 10: ...ontrol fan hot gas solenoid condensate pump hour meter TB2 TB1 jumper defrost control DC Com hour meter condensate pump purge switch defrost control com terminal power supply for fan NC and hot gas so...

Page 11: ...of nature or any other cause beyond Dry Air Technology s reasonable control End User Responsibilities Warranty service must be performed by a firm or individual authorized by Dry Air Technology If th...

Reviews: