background image

DRYPRO

 7000 OWNER’S MANUAL 

 

2

4.

 

Plug the unit into a grounded 

alternating current circuit and switch 
on the unit. 

5.

 

 Secure the 40 feet pump hose to a 

sink or alternative drain. 

6.

 

To use the gravity drain, connect the 

hose to the fitting on the back of the 
unit under the drip tray.  Place the 
hose into a suitable receptacle or 
drain connection. 

7.

 

Residual water left in the collection 

tray can be removed by using the 
manual purge switch.  Continue to 
depress switch until all water is 
removed. 

8.

 

If the unit is shut down for any 

reason, allow at least five minutes 
before restarting.  This will avoid 
damage to the compressor. 

9.

 

Assure that the fan and compressor 

are properly functioning before 
leaving a running unit unattended. 

MAINTENANCE 

 

Warning!

 

Disconnect the unit from the power 

supply before cleaning or servicing.

 

 

Filter Cleaning: 

The filter shroud must 

be cleaned after every job.  The filter 
itself should be vacuumed frequently to 
control the build-up of soil.  On a 
periodic basis, the filter should be 
removed completely from the unit.  It 
can be washed with water and mild 
detergent.  Allow the filter to thoroughly 
dry before reinstalling it in the unit.  

Coil Cleaning:

 As the coils accumulate 

soil, their heat transferring properties are 
reduced.  This can diminish water 

extraction and create undue pressure on 
the refrigeration system. 

The coils should be cleaned about every 
8 to 12 weeks.  If the DryPro

 7000 

Dehumidifier is used in a dusty 
environment, cleaning may need to be 
accomplished more frequently.  The 
coils should be dry before the following 
cleaning operation is performed. 

Dry Method.

  Inject compressed air 

through each coil.  Clean the unit’s front 
grill with a vacuum equipped with a 
brush attachment.  After removing the 
dry particle contamination, a wet 
cleaning process may be used. 

 

Caution! 

Do not use a hose to flush the coils 

and do not permit water to leak 

into the electrical compartment. 

Wet method

.  Use a soft brush and soapy 

water.  If soils have been allowed to 
accumulate over time, they may be dry 
and hard.  Soak time may be required to 
dissolve and release these soils from the 
coils.  A spray bottle or a syringe can be 
used to apply controlled amounts of 
cleaning solution.  After cleaning, make 
sure that the drain port, the condensate 
tray and drain tubing are free of any 
residual soil. 

Electrical Wiring & Cord: 

Inspect the 

power cord periodically to make sure 
that the insulation is in good condition.  
Replace worn or damaged cords.   

Remove the dehumidifier cover to 
expose the wiring and terminal block.  
Inspect wires to assure that they are 
secured away from the fan blade.  
Inspect the terminal block connections 
and wires for abrasions, nicks or cuts.  
Repair or replace as needed. 

Summary of Contents for DryPro 7000

Page 1: ...Dehumidifier Manual DRY PRO 7000 313 North Oak Street Burlington WA 98233 Tel 360 755 9176 Fax 360 755 9236 Toll Free U S Canada 888 755 9176 Email info dryairtech com www dryairtech com ...

Page 2: ... removed Personal injury may result Drapes or other loose fabrics can be drawn against the unit restricting its airflow This condition may cause the unit to overheat Assure that there is sufficient space between the back of the unit and these fabrics to avoid this condition Save the shipping carton in case your DryPro 7000 Dehumidifier must be returned for repair But discard the plastic bag to pre...

Page 3: ...This can diminish water extraction and create undue pressure on the refrigeration system The coils should be cleaned about every 8 to 12 weeks If the DryPro 7000 Dehumidifier is used in a dusty environment cleaning may need to be accomplished more frequently The coils should be dry before the following cleaning operation is performed Dry Method Inject compressed air through each coil Clean the uni...

Page 4: ... protection for the coil the DryPro 7000 has an easily removable and washable Quadrafoam Filter It is made with a special Uni Grid support and aluminum frame The DryPro 7000 features extra large 12 inch wheels to provide easy mobility and two flip up rubber sleeve handles mounted on both sides of the unit This makes transport much safer Back strain and stress is reduced during handling so there is...

Page 5: ...NN0235 Evaporator Coil RD 00M N2AN0075 Condensor Coil RD 00M N2AN0076 8 Fan Motor Assy RD 03M NNNN0089 Condensate Pump RD 00M P6NN0181 ICM Defrost Control RD 00E N6NN0236 ICM Defrost Control Mount RD 00C G8NN0407 Hour Meter RD 00E P5AN0099 3 8 Fitting Attached to Drip Tray RD 00M P3N70100 3 8 Hose Fitting Attached to 1 ft hose from pump to 40 Discharge hose RD 00M P3A7031 40 Discharge Hose RD 00M ...

Page 6: ...or improper repair or operation accident acts of nature or any other cause beyond Dry Air Technology s reasonable control End User Responsibilities Warranty service must be performed by a firm or individual authorized by Dry Air Technology If the end user is unable to locate or obtain warranty service from an authorized firm or individual he should contact Dry Air Technology at the above location ...