12
English
t r i o
-
i n s t r u c t i o n
f o r
i n s ta l l at i o n
8.3.1 First ignition of the appliance after installation or adjustments
!Caution
After installation, or after work has been performed, you should ignite the appliance for the first time without the glass
window. If necessary, bleed the gas pipe.
Follow the procedure described below:
➠
If required, remove the glass window;
➠
Start the ignition procedure according to chapter 4 in the User Manual;
➠
If the pilot flame does not ignite:
- repeat the ignition procedure until the pilot burner ignites;
- consult the malfunction search diagram (Chapter 11) if this does not happen after a few attempts;
➠
After igniting the pilot flame, the main burner will ignite during the ignition procedure;
➠
Check whether the main burner continues to burn;
➠
If the main burner does not continue to burn:
- repeat the ignition procedure until the main burner continues to burn
- consult the malfunction search diagram (Chapter 11) if this does not happen after a few attempts;
➠
Switch off the appliance;
➠
Then mount the glass window as described in chapter 6.9;
➠
Repeat the ignition procedure a few times and perform the checks described in chapter 8.3.2;
➠
From now on, the pilot flame should ignite smoothly.
!Caution
- During the ignition process, you are not allowed to operate control button B on the gas control manually.
- Always wait 5 minutes after the pilot flame has gone out, before you re-ignite the appliance.
- You are not allowed to turn the pilot flame lower by using the settings on the gas control.
8.3.2 Main burner
!Caution
- The pilot burner should ignite the main burner within a couple of seconds, and without popping.
- The main burner(s) must cross the full burner smoothly and without popping and continue to burn.
➠
Check operation of the main burner from a cold condition (pilot flame off):
➠
After opening the gas valve, the main burner should burn within a few seconds.
!Tip
When the gas valve is opened, the motor will start to run; this is audible.
The flame picture and a good flame transfer can only be properly judged if the glass window is installed.
Use the malfunction search diagram (Chapter 11) if the ignition of the main burner does not comply with the abo-
vementioned requirements.
8.4 Flame picture
The flame picture can only really be assessed when the appliance has been burning for several hours. Volatile com-
ponents from paint, materials, etc., which evaporate in the first hours, will affect the flame picture.
➠
Check whether the flame picture is acceptable.
➠
Consult the malfunction search diagram (Chapter 11) if the flame picture is not acceptable.
9. Maintenance
Once a year the appliance should be checked, cleaned and, if necessary, repaired by a competent installer in the field
of atmospheric gas heating.
Check at least whether the appliance is working properly and safely.
Caution
- Close the gas tap when performing maintenance work;
- Check the gastightness after repair;
- After replacing the thermocouple you should first tighten the swivel of the gas control block by hand and then give
it another quarter turn with a suitable spanner.
➠
If required, clean the following components:
- the pilot flame burner;
- the combustion room;
- the panes.
!Caution
- Remove/place the front pane as described in section 6.9;
- Remove the deposit on the inside of the pane with a damp cloth or a non-abrasive detergent such as copper polish;
- Avoid/remove fingerprints on the pane, as they will burn into the glass;
- Replace a torn or broken pane as described in section 6.9.
uk
Summary of Contents for G31 Propane
Page 19: ...19 E n g l i s h trio instruction for installation Fig 7 Fig 8 Fig 9 Fig 6 uk ...
Page 20: ...20 E n g l i s h trio instruction for installation Fig 10 Fig 12 Fig 11 Fig 13 UK ...
Page 21: ...21 E n g l i s h trio instruction for installation Fig 18 Fig 14 Fig 16 Fig 15 Fig 17 uk ...
Page 23: ...23 E n g l i s h trio instruction for installation Notes uk ...
Page 24: ...DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven ...