8.3.1 First ignition of the appliance after installation or adjustments

!Caution

   After installation, or after work has been performed, you should ignite the appliance for the first time without the glass 

window. If necessary, bleed the gas pipe.

Follow the procedure described below:

 

If required, remove the glass window;

 

Start the ignition procedure according to chapter 4 in the User Manual;

 

If the pilot flame does not ignite:
- repeat the ignition procedure until the pilot burner ignites;
- consult the malfunction search diagram (Chapter 11) if this does not happen after a few attempts;

 

After igniting the pilot flame, the main burner will ignite during the ignition procedure;

 

Check whether the main burner continues to burn;

 

If the main burner does not continue to burn:
- repeat the ignition procedure until the main burner continues to burn
- consult the malfunction search diagram (Chapter 11) if this does not happen after a few attempts;

 

Switch off the appliance;

 

Then mount the glass window as described in chapter 6.9;

 

Repeat the ignition procedure a few times and perform the checks described in chapter 8.3.2;

 

From now on, the pilot flame should ignite smoothly.

!Caution

  -  During the ignition process, you are not allowed to operate control button B on the gas control manually.

-  Always wait 5 minutes after the pilot flame has gone out, before you re-ignite the appliance.
-  You are not allowed to turn the pilot flame lower by using the settings on the gas control.

8.3.2 Main burner

!Caution

  -  The pilot burner should ignite the main burner within a couple of seconds, and without popping.

-  The main burner(s) must cross the full burner smoothly and without popping and continue to burn.

 

Check operation of the main burner from a cold condition (pilot flame off):

 

After opening the gas valve, the main burner should burn within a few seconds.

!Tip

 

When the gas valve is opened, the motor will start to run; this is audible.
The flame picture and a good flame transfer can only be properly judged if the glass window is installed.

Use the malfunction search diagram (Chapter 11) if the ignition of the main burner does not comply with the abo-
vementioned requirements.

8.4 Flame picture

The flame picture can only really be assessed when the appliance has been burning for several hours. Volatile com-
ponents from paint, materials, etc., which evaporate in the first hours, will affect the flame picture.

 

Check whether the flame picture is acceptable.

 

Consult the malfunction search diagram (Chapter 11) if the flame picture is not acceptable.

9.  Maintenance

Once a year the appliance should be checked, cleaned and, if necessary, repaired by a competent installer in the field 
of atmospheric gas heating.
Check at least whether the appliance is working properly and safely.

Caution

   -   Close the gas tap when performing maintenance work;

-   Check the gastightness after repair;
-   After replacing the thermocouple you should first tighten the swivel of the gas control block by hand and then give 

it another quarter turn with a suitable spanner.

 

 If required, clean the following components:
-   the pilot flame burner;
-   the combustion room;
-   the  panes.

!Caution

   -   Remove/place the front pane as described in section 6.9;

-   Remove the deposit on the inside of the pane with a damp cloth or a non-abrasive detergent such as copper polish;
-   Avoid/remove fingerprints on the pane, as they will burn into the glass;
-   Replace a torn or broken pane as described in section 6.9.

uk

Summary of Contents for G31 Propane

Page 1: ...1 E n g l i s h Trio G31 Propane Please retain this document carefully Instructions for installation GB IE 959 065 01 uk uk ...

Page 2: ...is guarantees that the user will be able to enjoy using his product for many years to come This appliance has a CE marking which means that it complies with the essential requirements of the European gas appliance directive As an installer you must be competent in the field of atmospheric gas heating Two manuals are supplied with the appliance the installation manual and the user manual The instal...

Page 3: ...a copy of the test certificate via www druservice com M J M Gelten General manager Postbus 1021 6920 BA Duiven Ratio 8 6921 RW Duiven www dru nl 3 SAFETY 3 1 General Caution Carefully read this chapter on safety before you start performing installation or maintenance work Please observe the general regulations and the precautions safety instructions in this manual 3 2 Regulations Please install th...

Page 4: ...egulations 6 Installation Read this manual carefully to ensure a proper and safe operation of the appliance Caution Install the appliance in the order described in this chapter 6 1 Regulations Please install the appliance in accordance with the applicable national local and constructional installation regulations Observe the regulations instructions in this manual 6 2 Type of gas The type plate in...

Page 5: ...ig 2 First a concentric pipe of at least 1 meter should be connected vertically to the appliance The total vertical pipe length can have a maximum of 4 meters On the vertical part a bend of 90 is connected Only wall ducts are allowed Under these conditions you should not install the restrictor slide 6 5 2 2 Placing concentric system with wall duct Place the concentric system as follows Build the s...

Page 6: ... of bends required no distinction is made between 45 and 90 bends 2 The total number of meters of horizontal pipe length 3 The total number of meters of vertical and or sloping pipe length These data will help you determine whether the concentric system is allowed by using Table 1 In Table 2 you can read which setting is required for the appliance Follow the procedure described below In the first ...

Page 7: ...ive plate for a flat roof or with a universally adjustable tile for a sloping roof Place the concentric system as follows Build the system up from the connection stump of the appliance Caution Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and or the ceiling Use heat resistant isolation material when passing through combustible material Caution Som...

Page 8: ... necessary blow through the gas pipe Connect the gas pipe with gas tap to the gas control block Caution You can find the gas control block behind the door in the space at the bottom of the appliance Do not turn the gas tap when connecting the gas pipe Bleed the gas pipe 6 7 Setting the appliance The appliance has to be set in such a way that is works correctly in combination with the discharge sys...

Page 9: ...fingerprints on the pane as they will burn into the glass Avoid damages when removing placing the glass pane Make sure the sealing tape at the edges of the glass pane is not damaged during removal 6 9 1 1 Removing the front pane When removing the front pane you should observe the instructions below see Appendix 4 Fig 14 to 17 Open the door Unscrew the 6 parkers of the glass strip at the sides by u...

Page 10: ...Fig 20 arrow C insert the plug into the wall socket Place the receiver in the control box as indicated on Fig 18 see Appendix 4 o Bend the antenna out of the clips see Appendix 4 Fig 20 arrow D and Fig 21 Set the antenna straight Caution Do not place the antenna too close to the ignition cable and or metal parts for the correct position see Appendix 4 Fig 21 Do not place the ignition cable over an...

Page 11: ...l the functions for high low position ignition and switching off Tip If the external control system has an intelligent clock function and or thermostat function the remote control sup plied with the appliance should have the manual mode in order to prevent interruption of these functions 2 Clock thermostat mode This mode of the remote control is active and will be responsible for the clock functio...

Page 12: ...The main burner s must cross the full burner smoothly and without popping and continue to burn Check operation of the main burner from a cold condition pilot flame off After opening the gas valve the main burner should burn within a few seconds Tip When the gas valve is opened the motor will start to run this is audible The flame picture and a good flame transfer can only be properly judged if the...

Page 13: ...lose the gas tap immediately in case of malfunctions bad performance and contact the installer in order to prevent dangerous situations Indicate the location of the gas tap Point out the precautions in the user manual against unintended ignition by other wireless remote controls such as car keys and garage door openers Instruct the user about the appliance and the remote control When the appliance...

Page 14: ... See that it does not fall away Clean with compressed air Rectify Retry 2 05 Check Ignition cable Present and connected Being free from metal parts or concrete Too long cut away all excessive length at receiver end and reconnect Shorting out to earth replace ignition cable Spark in wrong position slide rubber sleeve on ignition cable over ceramic of electrode Replace electrode if neccessary Igniti...

Page 15: ...urner dirty Weak pilot flame being drawn away by flames main burner Clean with compressed air See 2 04 2 15 Check Flames too low Supply pressure does not drop away as main burner or other appliances in the building light causing flames to shorten Burner pressure too low False air Check soundness glass window gasket soundness of the connection of the glass panes of two three sided appliances no slo...

Page 16: ...e rechargeables by alkaline batteries Communication code between remote and receiver has to be re set Press reset button on receiver until brief beep followed by long beep Release reset button and press flame low button on remote within 20 seconds Then 2 short beeps and brief noise of servomotor to confirm that communication code was set succesfully Remote control Battery 9V empty see indication o...

Page 17: ...cket spanner 1x Remote control with receiver 1x 9V block battery 1x Penlite battery AA type 4x Squeeze coupling 15 mm x G3 8 1x Appendix 2 Technical data In the following table you can find the technical data Table 6 Technical data Type C11 C31 C91 Type of gas G31 Burner pressure mbar 30 Nom load Hs kW 5 8 Nom load Hi kW 5 2 Nom output kW 4 0 Consumption L h 214 Burner injector mm front Ø 0 90 rea...

Page 18: ...18 E n g l i s h trio instruction for installation Appendix 4 Figures Fig 4 38 43 48 60 38c 1220 Fig 5 Fig 3 1 4m min 40mm 38c 744g 1x90 Fig 2 Fig 1 UK ...

Page 19: ...19 E n g l i s h trio instruction for installation Fig 7 Fig 8 Fig 9 Fig 6 uk ...

Page 20: ...20 E n g l i s h trio instruction for installation Fig 10 Fig 12 Fig 11 Fig 13 UK ...

Page 21: ...21 E n g l i s h trio instruction for installation Fig 18 Fig 14 Fig 16 Fig 15 Fig 17 uk ...

Page 22: ...22 E n g l i s h trio instruction for installation O A B 38C 2031 1 Fig 21 Fig 20 38p 0181 Fig 22 38p 0179 Fig 23 5mV 38p 0182 Fig 24 Fig 19 UK ...

Page 23: ...23 E n g l i s h trio instruction for installation Notes uk ...

Page 24: ...DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven ...

Reviews: