Tamarisk
®
640
Software ICD
49
3.3.11 AGC Gain Flatten Offset Set – 0xD2
Description
: Sets the gain limit offset for AGC histogram processing. The default value is
1.
NOTE
This command has no effect if ICE is enabled.
Command Format:
Table 90 – AGC Gain Flatten Offset Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xD2
AGC Gain Flatten Offset Set Command ID.
3
0x02
Parameters length.
4, 5
unsigned integer
0 to 65535
AGC gain flatten offset value.
6
checksum
Frame check sequence.
Response Format:
Table 91 – AGC Gain Flatten Offset Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x00D2
AGC Gain Flatten Offset Set Command ID.
6
checksum
Frame check sequence.
3.3.12 AGC Region of Interest – 0x84
Description
: Sets or gets the AGC Region of Interest (ROI). This command also returns
the allowable ROI Limit. This command also provides ability to burn all of the ROI to flash
NV Param.
NOTE
This command has no effect if ICE is enabled.