background image

 

16 

 

Before shipment, the VIP4Tools/Air lubrication panels are carefully packed inside a cardboard box. During transport and 

storage of the equipment, pay attention to the direction indicated on the box.  

Upon receipt, check that the packaging is not damaged and store the equipment in a dry place. 

 

13. PRECAUTIONS FOR USE 

 

The warnings and risks that using the panel implies must be carefully read. The user must be familiar with 

operation through the Operating Manual. 

 

Electrical current 

Do not carry out any operations on the machine before disconnecting it from the electrical power supply (on an 

electrical level) and ensuring that no one can reconnect it during the operation. 

All of the installed, electrical, electronic equipment, reservoirs and base structures must be connected to the 

ground line. 

(see section 6.7). 

 

Flammability 

The oil used in the lubrication circuits is a fluid that is not normally flammable. In any case, all possible measures 

must be taken to prevent it coming into contact with very hot parts or naked flames.  

Pressure 

Before any operation, check for the absence of any residual pressure in all branches of the lubricant circuit, that 

could cause spurts of oil in the event that fittings or components are disassembled  

(see section 6.6). 

 

Noise 

The VIP4Tools/Air lubrication panel does not  emit excessive noise, remaining below 70 dB (A). 

 

 

 

 

 

 

CHARACTERISTICS OF THE AIR 

 

Characteristics 

Operating Type 

Pressure at the hook-up point 

6 bar min (88.2 psi) 

Max. quantity of particles in suspension  

15 mg / Nmc 

Max. diameter of the particles 

0.05 

Dew point 

2° C (35.6 °F) 

Max. quantity of oil in suspension 

5 mg / Nmc 

 

If natural-based oils compatible with prevailing health regulations are not used, the mixing pressure must be calibrated in 

order to prevent the formation and dispersion of spray into the environment. 

The approximate mixing pressure is between 1 bar (14.7 psi) and 2.5 bar (36.7 psi).

 

 

                  

WARNING:

 before replacing the mini-pumps, remove the lubricant from the reservoir.

 

 

 

Summary of Contents for VIP4 Tools

Page 1: ...NSTRUCTIONS 8 MAINTENANCE PROCEDURES 9 DISPOSAL 10 ORDER INFORMATION 11 DIMENSIONS 12 HANDLING AND TRANSPORT 13 PRECAUTIONS FOR USE 14 CONTRAINDICATIONS OF USE VIP4 TOOLS Lubrication System Operating...

Page 2: ...subject to pressure Personnel must use protection equipment clothing and tools needed in relation to the location and the use of the panel both during operation and maintenance The integrity of the pa...

Page 3: ...amba type minimum level sensor Adjustable mini pumps 5 2 VIP4TOOLS CENTRAL UNIT WITH AIR SOLENOID VALVE The central unit of the lubrication system is made up of the following elements Reservoir made o...

Page 4: ...ts that are readily available on the market Modular sub base Samba type minimum level sensor Adjustable mini pumps The VIP4TOOLS with separate controls unlike the previous ones has separate inlets for...

Page 5: ...for 6 mm screws 6 3 ASSEMBLY OF THE MINI PUMPS ON THE MIXING BASES for expansion or replacement Assembly of the mini pumps on the mixing bases takes place using the two fixing screws Take care to cor...

Page 6: ...n see section 4 technical data The Vip4Tools Air with fixed flow rate pump comes with an inductive proximity sensor PNP NO 10 30Vdc to check for successful oil delivery Temperature limits 25 70 C 24V...

Page 7: ...ing operation adjust the pumps to the maximum flow rate running a few cycles 7 2 BY PASSING LUBRICANT DELIVERY OF THE SINGLE PUMP Unscrew anti clockwise the red cap located on the end of the pump unti...

Page 8: ...39 Periodically empty the condensation recipient from the pressure regulator rotating the red valve located at its base The machine does not require special tools for any check and or maintenance oper...

Page 9: ...vel ACCESSORIES PART NUMBER DESCRIPTION 5717300 Tube flexible 4 0 16 in 5717301 Tube flexible 6 0 23 in 3132572 1s 1 min timer kit 3132574 Solenoid valve 24 Vdc along with the kit the following must b...

Page 10: ...717301 Tube flexible 6 0 24 in 3132572 1s 1 min timer kit 45351 Solenoid valve 3v 1 8 GAS 24 Vdc 1524486 Lubrication nozzle 32 mm 1 26 in 1524487 Lubrication nozzle 48 mm 1 89 in 3226661 LRT 30 Oil fo...

Page 11: ...rdered Code 14067 quantity 2 6770072 3 Litre reservoir 1655583 Samba Level ACCESSORIES PART NUMBER DESCRIPTION 5717300 Tube flexible 4 0 16 in 5717301 Tube flexible 6 0 23 in 3132572 1s 1 min timer ki...

Page 12: ...Y STEEL STAINLESS STEEL REFRACTORY AND TITANIUM ALLOYS Saw cut Lathe turning Blanking Shearing 35 40 30 30 30 60 Boring Boring Milling Slotting 30 40 30 60 70 Threading Tapping Planing Shaving 60 70 8...

Page 13: ...hts mm in Kg lb 1 363 14 3 2 7 5 9 2 391 15 4 3 2 7 0 3 419 16 5 3 7 8 1 4 447 17 6 4 2 9 2 5 475 18 7 4 7 10 3 6 503 19 8 5 2 11 4 7 531 20 9 5 7 12 5 8 559 22 0 6 2 13 6 Electrical level Filler Cap...

Page 14: ...1 365 14 4 3 6 7 9 2 393 15 5 4 1 9 0 3 421 16 6 4 6 10 1 4 449 17 7 5 1 11 2 5 477 18 8 5 6 12 3 6 505 19 9 6 1 13 4 7 533 21 0 6 6 14 5 8 561 22 1 7 1 15 6 Electrical level Tappo di caricamento Mix...

Page 15: ...eights mm in Kg lb 1 362 14 25 3 4 7 5 2 390 15 35 3 9 8 6 3 418 16 46 4 4 9 7 4 446 17 56 4 9 10 8 5 474 18 66 5 4 11 9 6 502 19 76 5 9 13 7 530 20 87 6 4 14 1 8 558 21 97 6 9 15 2 12 HANDLING AND TR...

Page 16: ...s not normally flammable In any case all possible measures must be taken to prevent it coming into contact with very hot parts or naked flames Pressure Before any operation check for the absence of an...

Page 17: ...indicated in section 6 2 Contact with oil during top up maintenance The operator must have suitable PPE tit VIII 626 Use of unsuitable lubricant Main prohibited fluids Fluids Hazards Lubricants with a...

Reviews: