background image

2.

 

Remove the nozzle head from the articulated pipe, through which the Ø3 oil tube should pass, making it protrude 

approx. 20/25 mm. 

 

3.

 

Insert the Ø3 oil pipe in the push-in on the nozzle head. 

 

4.

 

Replace the nozzle head on the articulated pipe. 

 

To make it easier to remove the pipes exiting the module, use the device to remove Ø3 tube (code 1525475) not supplied: 

unscrew the Ø6 push-in, insert the device in the Ø3 pipe, push the device on the collar of the Ø3 push-in, push and pull the 

Ø3 pipe. 

 

7. OPERATING INSTRUCTIONS 

 

Operations to perform before start-up. 

 

Check the integrity of the unit; 

 

Check the power supply pressure; 

 

Check that the electric connection was carried out correctly; 

 

Check that the unit is at the operating temperature. 

 

7.1 USE 

 

Open the manual cursor valve; 

 

Press the start button on the machine to which the unit is connected or start it; 

 

Check that the solenoid valves on the elements are correctly activated; 

 

At the first start-up, it may be necessary to fill the oil pipes, wait until the lubricant exits; 

 

Check that the lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office can 

be contacted to request the inspection procedure). 

 

7.2 REGULATION 

The modular elements are normally supplied with the oil (NO CART version) regulation and the air regulation completely 

closed. To regulate the air/oil mixture for the individual elements, proceed as follows: 

 

Turn the oil regulation knob (NO CART version) anticlockwise to increase the flow rate or clockwise to decrease the 

flow rate. Following an orientation reference diagram for flow adjustment. 

 

 

 

 

Summary of Contents for MiQueL

Page 1: ...RUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15 OPERATING HAZARDS Manual drawn up in accordance wi...

Page 2: ...operator The outward oil and air flow can be managed independently between the different modules using a mini solenoid valve i version only or a pneumatic valve NO EV version only that activates the c...

Page 3: ...ting pressure in bar V viscosity Engler at operating temperature Lubricating oil 10cSt 100cSt Protection grade of module i Standard IP 00 On request special IP 65 Protection grade of reservoir IP 65 P...

Page 4: ...l Pressure switch optional Pressure gauge Loading cap with filter Device to remove 3 tube optional Visible level Modular element outlets Air inlet Mounting brackets Tank Minimum electric level Mountin...

Page 5: ...tions 6 3 PNEUMATIC CONNECTIONS Before making the connection check that the valve for the main air the manual sliding valve and the check valves air and oil are closed Make sure that the inlet pressur...

Page 6: ...s at the operating temperature 7 1 USE Open the manual cursor valve Press the start button on the machine to which the unit is connected or start it Check that the solenoid valves on the elements are...

Page 7: ...sert it to the end 9 MAINTENANCE PROCEDURE The units were designed and built in order to minimise maintenance requirements To simplify maintenance it is recommended to install them in an easy to reach...

Page 8: ...3135567 8 3135528 3135568 MiQueL BASE i Air Oil modular minimal system without compensation valve with solenoid valve for independent control 1 3135531 3135571 2 3135532 3135572 3 3135533 3135573 4 31...

Page 9: ...odular element 3132768 Kit FULL cone coaxial nozzle 3133559 AIR inlet solenoid valve kit 3133455 FULL cone coaxial nozzle 0020694 Pressure gauge for module AIR outlet i 3133558 65 FLAT jet coaxial noz...

Page 10: ...10 12 DIMENSIONS...

Page 11: ...on the machine before disconnecting it from the electrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and...

Page 12: ...maintenance activities Electrocution This can only occur in the case of serious user incompetence but the user must be qualified Unsuitable postures The correct dimensions and installation methods are...

Reviews: