6
2.
Remove the nozzle head from the articulated pipe, through which the Ø3 oil tube should pass, making it protrude
approx. 20/25 mm.
3.
Insert the Ø3 oil pipe in the push-in on the nozzle head.
4.
Replace the nozzle head on the articulated pipe.
To make it easier to remove the pipes exiting the module, use the device to remove Ø3 tube (code 1525475) not supplied:
unscrew the Ø6 push-in, insert the device in the Ø3 pipe, push the device on the collar of the Ø3 push-in, push and pull the
Ø3 pipe.
7. OPERATING INSTRUCTIONS
Operations to perform before start-up.
•
Check the integrity of the unit;
•
Check the power supply pressure;
•
Check that the electric connection was carried out correctly;
•
Check that the unit is at the operating temperature.
7.1 USE
•
Open the manual cursor valve;
•
Press the start button on the machine to which the unit is connected or start it;
•
Check that the solenoid valves on the elements are correctly activated;
•
At the first start-up, it may be necessary to fill the oil pipes, wait until the lubricant exits;
•
Check that the lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office can
be contacted to request the inspection procedure).
7.2 REGULATION
The modular elements are normally supplied with the oil (NO CART version) regulation and the air regulation completely
closed. To regulate the air/oil mixture for the individual elements, proceed as follows:
•
Turn the oil regulation knob (NO CART version) anticlockwise to increase the flow rate or clockwise to decrease the
flow rate. Following an orientation reference diagram for flow adjustment.
Summary of Contents for MiQueL
Page 10: ...10 12 DIMENSIONS...