5. ORDERING INFORMATION:
Part No.
Description
1639076
VIP Controller 24V Box Version.
1639077
VIP Controller 110/230V Box Version.
1639080
VIP Controller 24V Panel Mounted
Version.
1639084
VIP Controller 110/230V Panel Mounted
Version.
1639088
Remote Transmit Module.
1639081
VIP Controller 220V Single Phase in
Steel Enclosure.
1639087
VIP Controller 380V Three Phase in
Steel Enclosure.
6. SPARES
No user serviceable parts inside.
7. SAFETY REQUIREMENTS
These Controllers must be installed and operated in ac-
cordance with the requirements of this Instruction Sheet
and should not be used for any purpose than that specified
without the agreement of the suppliers.
In addition to the need to observe general safety require-
ments the following specific hazards apply:
Before installing or removing Advanced Lubrication Con-
trollers from the system disconnect and isolate all power
supplies.
8. OPERATING ENVIRONMENT
Controllers must not be operated in excessively corrosive
or aggressive environments. If in doubt, please contact
our Technical Office.
9. DIAGNOSTIC TABLE:
ALARM
CODES
DESCRIPTION
OF FAULT
ACTION
AO1
No parameters set. Set parameters.
AO2
Low Level alarm.
Add lubricant to the
system
AO3
The change-over
contact (in
SEP
mode) has not
cycled within the
specified
’Pump
ON ’
times.
Check for loose
fittings and
blockages in
progressive system
and rectify.
AO4
PS
Mode: Pressure
was already high
before the start of
the cycle.
Check pressure
switch and replace
if necessary.
AO5
PS
Mode: The
system did not
achieve pressure
during the specified
cycle times.
Check for leakage
from loose fitting
and rectify.
ALEX/DROPSA
Vimodrone (MI)
Tel: (02) 250791
Fax: (02) 25079767
DROPSA UK LTD.
Egham, SURREY.
Tel: (01784) 431177
Fax: (01784) 438598
DROPSA GMBH
Düsseldorf, GERMANY.
Tel: (0211) 394011
Fax: (0211) 394013
DROPSA FRANCE - AME.
Garges-Les-Gonesse, CEDEX.
Tel: (01) 399.300.33
Fax: (01) 398.626.36
DROPSA CORPORATION
Houston, TEXAS.
Tel: (713) 462-1061
Fax: (713) 462-4027
Fig. 4. Remote Transmitt Module.
© Copyright Dropsa - all rights reserved. Reproduction of any part of this document is strictly forbidden without prior consent from Dropsa.
Dropsa reserve the right to withdraw or modify specifications without prior notice.
4