background image

1. INTRODUCTION 

 

This user’s and maintenance manual refers to a 989 pump series for grease. 

It is recommended that this manual is carefully kept in good condition and is always available to persons requiring to 

consult it. 

To request further copies, updates or clarifications with respect to this manual contact the Engineering Department at 

Dropsa SpA. 

The use of the pump referred to in this manual must be entrusted to qualified personnel with a knowledge of 

hydraulics and electrical systems. 

The manufacturer reserves the right to update the product and/or the user’s manual without the obligation to revise 

previous versions. It is however, possible to contact the Engineering Department for the latest revision in use. 

The pump, and any accessories mounted on it, should be carefully checked immediately on receipt and in the event of 

any discrepancy or complaint the Dropsa SpA Sales Department should be contacted without delay. 

DROPSA S.p.A. declines to accept any responsibility for injuries to persons or damage to property in the event of the 

non-observance of the information presented in this manual. 

Any modification to component parts of the system  or the different destination of use of this system or its parts 

without prior written authorization  from DROPSA S.p.A. will absolve the latter from any responsibility for injury or 

damage to persons and/or property and will release them from all obligations arising from the guarantee. 

 

 

2. GENERAL DESCRIPTION 

 

The features which distinguish this pump are:  

 

high performance, 

 

simplicity of construction, 

 

modularity, 

 

The simplicity of construction guarantees long life, reliability and simplified and reduced maintenance. The modularity 

of the components allows the system engineer to construct the lubrication unit to meet the specific needs of the 

lubrication system it is serving. 

 

 

3. PRODUCT MACHINE IDENTIFICATION 

 

Machine identification yellow label is located on the front side of the reservoir and contains product serial number, 

input voltage and details of the operating parameters. 

 

 

4. TECHNICAL SPECIFICATIONS 

 

TECHNICAL CHARACTERISTICS 

Pressure  

300 Bar ( 4410 psi) 

Fixed delivery max (pumping Ø6 mm) 

10 cm

3

 / min (0.55 cu. in/min) 

Fixed delivery max (pumping Ø8 mm) 

17 cm

3

 / min (1.03 cu. in/min) 

Adjustable delivery max (pumping Ø6 mm) 

1,4-10 cm

3

 / min (0.085 - 0.61 cu. in/min) 

Adjustable delivery max (pumping Ø6 mm) 

2,5-17 cm

3

 / min (0.15 - 1.03 cu. in/min) 

No. pumpings 

1 ÷ 3 

Capacity reservoir 

5 kg. (11 lb) 

Lubricant 

Grease 

Lubricant Viscosity 

000 ÷ 2 NLGI 

Working Temperature 

+ 10° C ÷ + 40° C  (+50°  ÷ +104° F) 

Motor Voltage 

220/380 V – 50/60 Hz 

Power absorption 

90 W 

 

Summary of Contents for 989 Series

Page 1: ...TS 6 UNPACKING AND INSTALLING THE MACHINE 7 INSTRUCTIONS FOR USE 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING...

Page 2: ...on of use of this system or its parts without prior written authorization from DROPSA S p A will absolve the latter from any responsibility for injury or damage to persons and or property and will rel...

Page 3: ...ory It is possible to adjust working pressure by means of a by pass valve installed on delivery line The use of the by pass valve it s recommended to control the pump operating and to avoid over press...

Page 4: ...t of there being damage to the power supply cable or the unit DO NOT put the system into service Replace the damaged power supply cable with a new one The unit can be opened and repaired ONLY by quali...

Page 5: ...art button of the machine to which the 989 series pump is connected 3 Verify the starting of the pump 4 Verify the adequate lubrication of the machine if doubt exists as to the correct functioning con...

Page 6: ...es the bearing points in incorrect quantities The distributor is not correctly connected to the bearing points Verify that the dosages are those indicated in the system diagram Delivery is not correct...

Page 7: ...t the power and the hydraulic supplies are off and there is no residual pressure in the main branch pipe Adjustable delivery pumping unit Part No 299041 6 mm Part No 299042 8 mm Fixed delivery pumping...

Page 8: ...it will be necessary as previously described to connect the pump to the machine hydraulically and then to connect the control panel During the disassembly phase ensure the tank is empty Disconnect the...

Page 9: ...e Electro pump 1 pumping unit 8 mm 24 V DC 989011 Grease Electro pump 1 pumping unit 6 mm 989012 Grease Electro pump 1 pumping unit 8 mm Part No Description 220 380 V 50 60 Hz 989003 Grease Electro pu...

Page 10: ...precautions are required except as noted on the package itself Handling must be effected by at least two persons POS DIMENSIONS mm in A 539 5 21 24 B 334 13 15 C 71 2 79 D 220 8 66 E 120 4 72 FOR WAL...

Page 11: ...ase it is possible to encounter squirts of oil for this reason appropriate protective clothing must be worn contact with oil see the requirements for the use of suitable personal protective clothing u...

Page 12: ...paid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will per...

Page 13: ...ed le produit appel das Produkt mit dem Namen el producto que se llama o produto chamado Descrizione Description Description Beschreibung Descripci n Descri o Pompa a pistoni Piston pump Nome Commerci...

Page 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Reviews: