background image

 

13. TRANSFER AND TRANSPORTATION 

Before shipment, the pumps are carefully packed inside a cardboard box. During transport and storage of the equipment, pay 
attention to the direction indicated on the box. On receipt, check that the packing is not damaged and store the equipment in  a 
dry place.  

 

 

 

 

14. PRECAUTIONS FOR USE 

The warnings on risks using a lubricant pump implies must be carefully read. 
The operator must be familiar with the functionality and clearly understand the dangers connected with pumping greases under 
pressure. We therefore recommend: 

 

Checking the chemical compatibility of the pump construction materials with the fluid that you intend to pump (see the table 
at the end of Section 14). An incorrect choice could cause, in addition to damage to the pumps and the lines, serious risk to 
personnel (leaking of products that are irritants and harmful to the health) and to the environment. 

 

Use only original spare parts. 

 

If  you  must  replace  components  with  others,  ensure  that  they  are  suitable  to  function  at  the  pump's  maximum  operating 
pressure.    

 
 
 

 

Note: Personnel must use protection equipment, clothing and tools that comply with the prevailing regulations in relation to the 
location and the use of the pump both during operation and maintenance. 

 
 
 

 

Flammability 

The lubricant used in the lubrication circuits is a fluid that is not normally flammable. In any case, all possible measures must be 
taken to prevent it coming into contact with very hot parts or naked flames.  

Pressure 

Before any operation, check for the  absence of any residual pressure in all branches of the lubricant circuit, that could cause 
spurts of oil in the event that fittings or components are disassembled. After long periods of inactivity, check the seal on  all the 
parts subject to pressure. Do not subject the fittings, pipes and the parts under pressure to violent impact. A damaged hose or 
fitting is DANGEROUS. Replace it. We recommend using only original spare parts. 

 
 
 
 
15. OPERATING INDICATIONS 

The pumps do not have particular contraindications except for the following points: 

 

Operator contact with lubricant via ruptured/open pipes or during reservoir maintenance/filling procedures. Protection 
against  direct  and  indirect  contact  with  the  fluid  must  be  provided  by  the  user:  The  operator  must  be  equipped  with 
appropriate PPE (ClassVIII – 626).
 

 

Use of unsuitable lubricant. Main prohibited fluids: 

Fluid 

Hazard 

Lubricants with abrasive additives 

High wear of the contaminated parts 

Lubricants with silicon additives 

Seizing of the pump 

Petrol – solvents – flammable liquids 

Fire – explosion – damage to gaskets 

Corrosive substances 

Corrosion of the pump – damage to personnel 

Food substances 

Contamination of the same 

 

Lift the equipment bearing in mind the direction indicated on the box. 
The components of the pump can withstand temperatures during storage from -20°C to + 65°C. However, in order to prevent 
damage, use must take place when the pump has reached a temperature of +5 °C.
 

 

 

ATTENTION

Never try to stop or deviate any leaks with your hands or other parts of the body. 

 

 

ATTENTION

The warnings on risks using a lubricant pump implies must be carefully read. The user must be familiar with 

operation through the Operation and Maintenance Manual. 

 

NOTE: 

The pump is designed to work with maximum 220 cST grade lubricants. Use NBR-seal compatible lubricants. The lubricant 
used for assembling and testing possibly remaining inside is 32 cSt oil.
 

 