background image

 

6.2 INSTALLATION  

There is no assembly required for the pump. 
Provide adequate space for installation, leaving a minimum clearance space of 100 mm (3.93 in.), 
For mounting to wally, it is necessary to provide adequate space (as is indicated by the installation diagram). Subsequently, it is 
necessary to hydraulically connect the pump. During the disassembly phase, disconnect the hydraulic part. 

 

7.  OPERATING INSTRUCTIONS 

7.1 PRELIMINARY OPERATIONS 

-

 

Check the integrity of the pump. (The unit can be opened and repaired only by specialized personnel.) 

-

 

Ensure that the hydraulic connection has been carried out correctly. 

-

 

Use lubricant that is free of impurities. 

 

7.2 PUMP USE 

The pump is mechanically operated by reciprocating action of the machine. It is important that the operating system allows for 
the technical specifications of the project to be adhered to (stroke length, max. number of pumping cycles, etc.). The pump has 
a reverse function where the piston is pressed, it goes into suction mode, while, when it is released, the oil is delivered for use. 
We recommend carrying out a few cycles to bleed the air from the system. 

 

Using  the  pump  submerged  in  fluids  or  in  a  particularly  aggressive  or  explosive/flammable  environment  is  prohibited 
unless it has been prepared ahead of time by the supplier for this purpose. 

 

Wear gloves and eye protection as required by the oil lubricant safety data sheet. 

 

DO NOT use aggressive lubricants for NBR gaskets; in the case of doubt, contact the technical office. 

 

Never ignore health hazards and always follow sanitary regulations.  

 
8. PROBLEMS AND SOLUTIONS 
 

FAULT 

CAUSE 

SOLUTION 

The  pump  does  not  dispense 

the exact prescribed quantity 
 

The  pump  sucks  air  because  the 
reservoir* is empty 

Fill the reservoir* and bleed the system air 

The fittings are loose 

Carefully  tighten  all  the  fittings,  ensuring  that 
there are no leaks 

The pump does not dispense oil 
at the prescribed pressure. 

Damaged pump 

Replace the pump 

The  pump  does  not  dispense 
and  only  weakly  sucks  oil  from 

the reservoir. 

The check valve during suction can be 

dry after long periods of non-use. 

Remove  the  suction  fitting  and  allow  a  few  drops 
of  oil  fall  onto  the  90°  valvular  fitting.  During  the 

first  pumping  cycles,  the  suction  phase  is  forced, 

making  it  prolonged  compared  to  the  release 
phase,  thereby  allowing  the  pump  to  come  under 

pressure and fill the suction hose faster. 

* The reservoir is not included within the scope of supply. 

 

 

9. MAINTENANCE PROCEDURES 

The pump has been designed and built in a way to require minimum maintenance. 
In order to simplify maintenance, we recommend installing it in a position that is easy to reach.Periodically check the joints of 
the pipes and always keep clean the pump for leakage or faults. 
The machine does not require special tools for any check and/or maintenance operations. It s recommended to use suitable 
equipment and personal protective equipment (gloves) that are in good condition in accordance with applicable regulations to 
avoid injury to people or damage parts of the pump.   
 
 

 
 

 
In  the  event  of  doubts  and/or  irresolvable  problems,  do  not  search  for  the  fault  by  disassembling  parts  of  the  machine,  but 
rather contact the Dropsa Technical Office S.p.A. 

ATTENTION: Ensure that the hydraulic power supply is disconnected before carrying out any maintenance operations. 

 

Reviews: