7. INSTRUCTIONS FOR USE  

 

7.1 PRELIMINARY CHECKS 

-

 

Verify the unit is undamaged. 

-

 

Check that the hydraulic connections has been carefully carried out. 

-

 

Refill the reservoir with impurity-free lubricant.  

 

 

7.2

 

PUMP OPERATION 

Operating the pump is very easy: to deliver lubricant simply pull and push completely  the hand control lever and then release. 

We recommend to carry out some lubrication cycles to discharge air from the system. 

 

 

8. TROUBLESHOOTING  

 

 

ANOMALY 

CAUSE 

SOLUTION 

Pump does not deliver 

lubricant. 

 

Pump does not deliver 

the proper quantity of 

lubricant. 

 

Pump intakes air because the 

reservoir is empty 

 

Refill the reservoir and discharge air form the system. 

 

Loose fittings 

Tighten the fittings. Be sure there are no leaks. 

Obstructed filter. 

Clean or replace the filter  

Incompatible lubricant 

Verify lubricant thickness/viscosity and replace it, if necessary. 

Pump does not deliver 

lubricant at the proper 

pressure 

 

Pompa deteriorata 

Sostituire pompa 

By-pass valve not regulated 

properly 

 

Regulate the pressure valve (3294002) 

 

 

9. MAINTENANCE PROCEDURE 

 

The machine does not require any special tool for checking or maintenance tasks. However, it is recommended the use only of 

appropriate and in good conditions tooling, protective devices (gloves) and clothing  to avoid hazards to equipment or persons. 

 

The machine has been designed and manufactured to require the minimum maintenance: 

 

Keep the unit clean and periodically check the pipe joints to detect possible leaks.  

 

 

10. DISPOSAL  

 

During maintenance or disposal of the machine care should be taken to properly dispose of environmentally sensitive items. 

Refer to local regulations in force in your area.  

When disposing of this unit, it is important to ensure that the identification label and all the other relative documents 

are also destroyed. 

 

 

 

 

 

 