5. PUMP COMPONENTS  

 
 

 

Pump body

 

Hand control lever

 

Reservoir

 

 

Pressure gauge

;

 

 

By-pass valve

.

 

 
 

 

 
 
 

6. UNPACKING AND INSTALLING THE PUMP 

 

6.1 UNPACKING 

Once a suitable location has been found to install the unit remove the pump from the packaging. Check the pump has not been 

damaged during transportation or storage. No particular disposal procedures are necessary, however packing should be disposed 

of in accordance with regulations that may be in force in your area or state. 
 

6.2 INSTALLING THE PUMP 

 

Allow sufficient space for the installation, leaving minimum 100 mm (3.9 in.) around the unit. 

 

In order to avoid unnatural posture for personnel install the machine in a comfortable and easy-to-reach location. 

 

Do not install the unit in aggressive/explosive/inflammable environments or on vibrating surfaces. 

 

For the fixing use only the bracket arranged with n°3 holes Ø10.5 mm (0.4 in.). 

 
6.3 HYDRAULI CONNECTIONS 

Connect the system to pump outlet thread ¼ BSP. 
 

 
 

PUMP BODY 

WARNING

: At the end of all the connecting operations, make sure that pipes and wires are safe from impacts 

and carefully fixed. 

 

 