3
5. PUMP COMPONENTS
•
Pump body
;
•
Hand control lever
;
•
Reservoir
;
•
Pressure gauge
;
•
By-pass valve
.
6. UNPACKING AND INSTALLING THE PUMP
6.1 UNPACKING
Once a suitable location has been found to install the unit remove the pump from the packaging. Check the pump has not been
damaged during transportation or storage. No particular disposal procedures are necessary, however packing should be disposed
of in accordance with regulations that may be in force in your area or state.
6.2 INSTALLING THE PUMP
•
Allow sufficient space for the installation, leaving minimum 100 mm (3.9 in.) around the unit.
•
In order to avoid unnatural posture for personnel install the machine in a comfortable and easy-to-reach location.
•
Do not install the unit in aggressive/explosive/inflammable environments or on vibrating surfaces.
•
For the fixing use only the bracket arranged with n°3 holes Ø10.5 mm (0.4 in.).
6.3 HYDRAULI CONNECTIONS
Connect the system to pump outlet thread ¼ BSP.
PUMP BODY
WARNING
: At the end of all the connecting operations, make sure that pipes and wires are safe from impacts
and carefully fixed.