background image

6.4.

 

ELECTRICAL CONNECTIONS 

Only for the versions with electrical contact for minimum level check, carry out the connection as per the diagram indicated 
below. Nominal capacity of the contacts = 15A 125/250V AC 

 

 

7.

 

OPERATING INSTRUCTIONS 

7.1.

 

MEASURES TO BE TAKEN PRIOR TO START-UP 

 

The unit may be put into operation by specialized personnel. 

 

Use gloves and eye protection as provided for in the lubricant safety data sheet. 

 

DO NOT use lubricants that are aggressive to NBR gaskets. If you are unsure, contact the Dropsa S.p.A technical office for 
a detailed list of recommended lubricants. 

 

Never ignore health hazards and always follow sanitary regulations. 

 

Always use suitable piping for the operating pressure. 

 

Check the integrity of the pump. 

 

Check the lubricant level using the dipstick located on the reservoir. If the level is low, proceed as described in section 7.2. 
FILLING LUBRICANT 

 

Ensure that the pump operates at operating temperature and that the pipelines are free of any air bubbles. 

 

Check the correct connection of electrical devices. 

 
To determine the maximum operating pressure, it is necessary to know the pressure drop of the pipeline connected to the 
pump: internal diameter, length, operating temperature and type of lubricant. 
Depending on these variables to achieve a proper supply to the delivery point, it is always necessary to ensure that the pipeline 
pressure loss plus the pressure required at the lubrication point does not exceed the maximum pressure supplied for pump 
delivery. 

7.2.

 

FILLING LUBRICANT 

For the versions with built-in reservoir, you must proceed as follows: 

 

Remove the protection plug. 

 

Tighten the fittings necessary for filling (thread present G ½ UNI ISO 

 228/1 male). 

 

Start the fill pump until reaching the desired level (without exceeding the max level line). 

 

For the first filling, you must press the button on the handle of the dipstick to evacuate the air inside. 

 

If the maximum level is exceeded, you will notice a leakage of lubricant from the hole on the reservoir itself. 

 

Remove the fitting. The valve will keep the grease from coming out. 

 

Refit the protection plug. 

7.3.

 

REGULATIONS 

The delivery pressure is in a 4.8:1 ratio (single acting versions) or 1:1 (dual acting versions) with the feed pressure, therefore 
adjust the latter based on the needs of the system. 

 

For the adjustment of the flow rate, you must proceed as follows: 

 

Remove the protection plug. 

 

Loosen the locknut (A) using a number 13 wrench to release the screw (B) 

 

Use the appropriate size screwdriver to tighten (decrease flow rate) or loosen (increase flow rate). 

 

Once the regulation has been completed, tighten the locknut (A). 

 

Refit the protection plug. 

 

 

A        B 

Summary of Contents for 3414 Series

Page 1: ...nches and authorised distributors Go to www dropsa com or write to sales dropsa com C2014IE WK 14 19 1 INTRODUCTION 2 GENERAL DESCRIPTION 3 PRODUCT IDENTIFICATION 4 TECHNICAL CHARACTERISTI 5 COMPONENT...

Page 2: ...out reservoir for applications on special reservoirs or reservoirs owned by the customer Fitted with plate with holes for lubricant entry with G UNI ISO 228 1 threading 3 PRODUCT IDENTIFICATION A yell...

Page 3: ...DUAL ACTING VERSION WITH RESERVOIR Fixing bracket Identifying tag ELECTRIC Minimum level Reservoir fill inlet G Lubricant outlet Rp Dual acting inlet outlet G Control cylinder Reservoir Level check d...

Page 4: ...al posture or possible impact Do not install the pump submerged in liquids and or in aggressive environments Do not install the pump in environments where there are explosive or flammable mixtures Ens...

Page 5: ...ype of lubricant Depending on these variables to achieve a proper supply to the delivery point it is always necessary to ensure that the pipeline pressure loss plus the pressure required at the lubric...

Page 6: ...tighten all the fittings ensuring that there are no leaks The piston of the pumping element is worn out Replace the piston The delivery valve is blocked Replace the valve The pump does not dispense lu...

Page 7: ...t disposal Upon demolition of the pump the identification label and any other document must be destroyed 11 ORDER INFORMATION Version WITH RESERVOIR for GREASE Part number Command Grease Characteristi...

Page 8: ...050 523 20 6 736 28 97 196 7 7 280 11 02 75 2 95 3414022 511 20 1 661 26 02 192 3 5 276 10 86 75 2 95 3414014 Dual acting 511 20 1 761 29 9 192 3 5 276 10 86 75 2 95 Version WITHOUT RESERVOIR for OIL...

Page 9: ...NBR gasket compatible lubricants Any residual lubricant inside that was used for assembly and testing is NLGI 0 grade 15 CONTRAINDICATIONS OF USE Compliance with the essential safety requirements and...