7.5 SET-UP AND CONFIGURATION OF THE ELECTRONIC CONTROL
SELECT THE OPERATING MODE :
Press and hold the key for at least 2 seconds. The unit will go into its set-up mode.
Select the Operation mode DISEPNSE (‘dISP’) or CHAIN (‘ChA’) by using the UP/DOWN keys and then press to
continue.
According to which is selected the menu will vary. Follow the step-by-step parameter guide below to setup the
unit accordingly. Use to step to the next parameter and UP/DOWN keys to vary the setting on the current
parameter:
CHAIN MODE PARAMETERS
Parameter
Display
Description
Operation
Default
Number of
Lubrication Cycles
Number of times the pumps are activated
during the lubrication cycle. From 0001 a 9999.
Set the value using
the and keys
10
Standby Interval
Determines the length of the Standby intervals
by counting impulses from remote switch.
Set the value using
the and keys
100
Standby
Multiplication
Factor
Multiplies the previous value by 1, 10 , 100 or
1000 to obtain upto 9,999,000 standby
impulses
Set the value using
the and keys
1
Number of Micro-
Pumps
Number of Micropumps installed on the system
with Flow Sensing. Setting this to 0 will disable
flow sensing on all micropumps. If you set less
than the number of micropumps installed than
the nearest ones will be monitored, while the
furthest will remain unmonitored. EG. Setting 5
of a 6 pump system will result in the last pump
not being monitored..
Set the value using
the and keys
Min. 0
Max. 6
Micropump
Activen and Air
On-Time
During the lubrication cycle, the system will
trigger a lubrication shot with each impulse.
This setting determines the length of the
lubrication Shot and how long the air will
remain on for.
Ensure that the duration does not exceed the
time between impulses from the remote switch
for proper operation. 0 a 9,9 sec.
Setting this parameter to 0 will cause the Air
Shot to remain active for the duration of the
impulse from the remote switch
Set the value using
the and keys
1
Min air pressure
Minimum Air Pressure monitoring during cycle.
Setting 0.0 disables minimum air pressure
monitoring. Range 0.0-7.0 bar.
Set the value using
the and keys
0,0
Max air pressure
Maximum Air Pressure parameter during cycle.
Setting 0.0 disables monitoring.Range 0.0-7.0
bar
Set the value using
the and keys
2,5
MODE
MODE
MODE