13. HANDLING AND TRANSPORT
Before shipping, the pumps are carefully packed inside a cardboard box. When transporting and storing the equipment, pay
attention to the direction indicated on the box itself. Upon receipt, check that the package has not been damaged and store the
equipment in a dry location.
14. PRECAUTIONS FOR USE
The warnings about the risks involved in using a pump for lubricants must be read.
The operator must understand its operation and clearly understand the hazards connected to pumping pressurised grease.
Therefore we recommend the following:
Check the chemical compatibility of the material with which the pump is built with the fluid to be pumped (see the table at the
end of paragraph 14). An incorrect selection could cause, in addition to damaging the pumps and pipes, serious risks for people
(spillage of irritating products that are harmful to health) and for the environment.
Never exceed the maximum operating pressure permitted for the pump and the components connected to it. In the case of
doubt, refer to the data specified on the machine plate.
Only use original spare parts.
If components must be replaced with others, make sure they are suitable for operating at the pump's maximum operating
pressure.
Note:
Personnel must use protective devices, garments and tools in compliance with current standards with regard to the location
and the use of the pump both during work as well as during maintenance operations.
Inflammability
The lubricant used in the lubrication circuits is normally not an inflammable liquid. It is however necessary to adopt all the
possible measures to prevent that it comes into contact with very hot parts or open flames.
Pressure
Before each operation, make sure there in every branch of the lubrication circuit that there is no residual pressure that could
cause oil to spray when disassembling fittings or components. After long periods of inactivity, check the seal of all the parts
subject to pressure. Do not subject the fittings, pipes and pressurised parts to violent impacts. Damaged flexible pipes or fittings
are DANGEROUS and must be replaced. Only original spare parts should be used.
A comparison table is provided between the classification of NLGI lubricants (National Lubricating Grease Institute) and the
ASTM classification (American Society for Testing and Materials) for greases for the values that concern the pump.
Lift the equipment according to the direction shown on the cardboard package.
The pump components can be stored at temperatures between -20 and + 65 °C; however, to prevent damage, it must only
be started up after the pump has reached a temperature of +5 °C.
ATTENTION!
Never tryto stop or deviate any leaks with your hands or other body parts.
ATTENTION
:
The warnings about the risks involved in using a pump for lubricants must be read. The user must understand
its operation using the user and maintenance manual.
NOTE:
The pump was designed to operate with lubricants with a maximum rating NLGI 00. Use lubricants that are compatible with
NBR gaskets. Any internal residual lubricant used for assembly and testing purposes is 32 cSt oil
GREASES
NLGI
ASTM
000
445 – 475